• Title/Summary/Keyword: 임피던스 계수

Search Result 230, Processing Time 0.023 seconds

Surface Transfer Impedance Measurement of RF Cable according to IEC Standard 96-1 (IEC Standard 96-1에 따른 RF 케이블의 표면전달 임피던스 측정)

  • 강진섭;김정환;강웅택;박정일
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.886-892
    • /
    • 2000
  • In this paper, surface transfer impedance measurement of RF cables according to IEC(International Electrotechnical Commission) Standard 96-1 is described and surface transfer impedance of a commercial RF cable is obtained from the measured voltage and scattering parameter with a triaxial fixture fabricated in the operating frequency range from 1 MHz to 30 MHz.

  • PDF

An Experimental Study on the Absorption Performance of Steel-Wire Sound Absorbing Materials (금속와이어 흡음재의 흡음성능에 관한 실험적 연구)

  • 서성원;용호택;이동훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.5
    • /
    • pp.413-421
    • /
    • 2003
  • The acoustic performances of steel-wire sound absorbing materials with different thicknesses and bulk densities were investigated experimentally. The well-known two-cavity method was used to measure the characteristic impedance, propagation constant and absorption coefficient. The normal absorption coefficients measured by two-cavity method agreed well with those by the two-microphone impedance tube method. The experimental results showed that the magnitude of the absorption coefficient and the frequency range of the maximum absorption coefficient were controllable by changing the thickness and bulk density of the steel-wire. Therefore, the steel-wires obtained from the crushed tire chips could be used as a good absorbing material.

Damage Monitoring of PSC Girder Bridges based on Acceleration -Impedance Signals under Uncertain Temperature Conditions (불확실한 온도 조건하의 PSC 거더 교량의 가속도-임피던스기반 손상 모니터링)

  • Hong, Dong-Soo;Kim, Jeong-Tae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.1
    • /
    • pp.107-117
    • /
    • 2011
  • In this study, the effect of temperature-induced uncertainty to damage monitoring using acceleration-impedance response features is analyzed for presterssed concrete(PSC) girder bridges. Firstly, a damage monitoring algorithm using global and local vibration features is designed. As global and local features, acceleration and electro-mechanical impedance features are selected respectively. Secondly, the temperature effect on the acceleration and impedance features for a lab-scaled PSC girder is experimentally analyzed. From the experimental results, compensation models for temperature-acceleration features and temperature-impedance features are estimated. Finally, the feasibility of the acceleration-impedance-based damage monitoring technique using the compensation model is evaluated in the PSC girder for which a set of prestress-loss and flexural stiffness loss cases were dynamically tested.

Brief Note on Acoustic Impedance Characteristics at Flow Boundaries (경계에서의 음향 임피던스 특성에 대한 연구 고찰)

  • Seo, Seonghyeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.6
    • /
    • pp.103-109
    • /
    • 2017
  • An increase in acoustic energy in a combustion chamber coupled with heat fluctuations from flame results in the occurrence of combustion instability. The assessment of combustion stability requires the prediction of acoustic energy variation by understanding the acoustical characteristics of flow boundaries in a combustion chamber. The present paper discusses about the characteristics of acoustic impedances at boundaries in terms of Strouhal number and summarizes theoretical analyses on the acoustic characteristics of injector-head-like configurations. Also, the details of the two-microphone measurement technique have been presented.

Development of Bioelectrical Impedance Analyzer for Korean in Telemedicine (원격의료계측을 위한 한국형 생체 전기 임피던스 분석 시스템의 개발)

  • 문재국;서광석;임택균;신태민;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.413-418
    • /
    • 2002
  • The purpose of this study was to design a single frequency BIA(Bioelectrical Impedance Analyzer) which can measure body impedance when patient is sitting on the toilet and to develope a prediction equation for designed BIA. For the purpose of this study, we acquired body impedances with designed BIA from 181 subjects composed of healthy Korean by attaching electrodes to suitable positions(wrist and thigh) for toilet measurement. We computed an appropriate FFM(Fat Free Mass) for Korean using modified-Siri equation to the same subjects instead of Siri equation which nay cause accuracy problems in hydrodensitometry when it applied to Korean. We used this FFM as reference value and developed a Korean FFM prediction equation based on body impedance index, body weight and sex. Correlation coefficient between prediction value and reference value of FFM was extremely high (r = 0.977) and SEE(Standard Error of Estimation) was low 2.47kg.(p<0.05) For comparison between existing electrode-attaching method and our method for toilet measurement, we acquired body impedance with designed BIA from same subjects attaching electrodes on existing positions (wrist and ankle) and made FFM prediction equation for BIA. Correlation coeffient between predicted value and reference value was 0.978 and SEE was 2.43kg(p<0.05). It means that the developed system has not significant differences with existing method. In conclusion bioelectrical impedance analyzer and the FFM prediction equation developed in this paper are evaluated to he adequate to compute FFM of Korean.

Humidity Sensitive Properties of Polymer Electrolytes of Quaternary Ammonium methacrylate derivatives (메타크릴레이트계 4차 암모늄 유도체 고분자 전해질의 감습특)

  • Kim, Tae-Mi;Gong, Myeong-Seon;Lee, Im-Yeol;Park, Jeong-Gi
    • Korean Journal of Materials Research
    • /
    • v.3 no.6
    • /
    • pp.598-605
    • /
    • 1993
  • Methacryloxyethyl dimethyl alkyl($C_{1}\sim C_{12}$, benzyl and 2, 2-diethoxy ethyl) ammonium bromide monomers were prepared to investigate the relative humidity characteristics for polymer electrolytes with different chemical structures. They were coated on the alumna substrate printed comblike gold electrode by photopolymerization after micro-syringe injection. As the thickness of rhe humid membrane increased, the impendance decreased, whereas the impedance ~ncreased as the carbon cham of alkyl substituent in the monomer increased. The impendance of the polymeric electrolytes with $C_6\sim C_8$ substituents were varied from 19M$\Omega$ to 5K$\Omega$ for the range of 30-90% Mi. The temperature depedence coefficient in the range of 15-$35^{\circ}C$ was found to be -0.45% $RH/^{\circ}C$and the hysteresis falled within the range of $\pm$2% RH. The response time was 35 second for varying humldity from 33% to 85% RH.

  • PDF

A Study on the Evaluation of Piezoelectric Thin Film Characteristics in Composite Resonator Structure Using Resonance Spectrum Method (공진주파수 스펙트럼법을 이용한 Composite Resonator 구조에서 압전박막의 특성 평가에 대한 연구)

  • Choi Joon Young;Chang Dong Hoon;Kang Seong Jun;Yoon Yung Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • We studied the characteristics of impedance and electromechanical coupling coefficient in ZnO and AIN thin films by using resonance frequency spectrum method. The response peak of impedance decreased with the decrease of thickness of piezoelectrics, the number of mode of response peak decreased with the decrease of substrate thickness. An error of Kt² estimated from input Kt² increased as the thickness of piezoelectrics decreased and the thickness of substrate increased. Also, the error was increased in case of a large acoustic impedance of substrate. It was found that the composite resonator operating in optimized condition could be designed through the resonance frequency spectrum analysis of composited resonator consisted of piezoelectric thin film and substrate.

Wideband Power Divider Using a Coaxial Cable (동축선을 이용한 광대역 전력 분배기)

  • Park, Ung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.661-668
    • /
    • 2012
  • A coaxial-cable impedance transformer that can be used in high power and wideband frequency range is an arbitrary impedance transformation ratio by an additional coaxial cable. The coaxial-cable impedance transformer to be 50-${\Omega}$ to 25-${\Omega}$ impedance transformation ratio is easily operated an wideband power divider by connecting two 50-${\Omega}$ lines at 25-${\Omega}$ impedance point. This wideband power divider has a poor output matching characteristic and a poor isolation characteristic between two output ports. In this paper, it proposes a coaxial-cable power divider to be a good output matching and isolation characteristics as it uses the singly terminated filter design theory. The odd-mode operation characteristic of the suggested power divider to use singly terminated low pass filter coefficient due to matching order and ripple value is examined by ADS program. And, it fabricates and measures the operation characteristic of 2-way power divider with 2nd-order and 4th-order matching circuit.

Clamped capacitance control of a piezoelectric single crystal vibrator using a generalized impedance converter circuit (범용 임피던스 변환회로를 이용한 압전 단결정 진동자의 제동용량 제어)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.1
    • /
    • pp.46-52
    • /
    • 2018
  • The piezoelectric single crystals used in piezoelectric transformers have a problem that power transfer capacity is comparatively low due to their high input impedance. In this study, we suggest a method to improve the power transfer capacity by reducing the high input impedance of the piezoelectric single crystal vibrator by connecting a capacitance increasing circuit to the electrical terminals of the piezoelectric single crystal vibrator where the circuit is a GIC (Generalized Impedance Converter) circuit using operational amplifiers. The result of measuring driving characteristics after applying the designed capacitance increasing circuit to the $128^{\circ}$ rotated Y-cut $LiNbO_3$ crystal vibrator confirmed that the input impedance decreased by 25 %, electromechanical coupling factor increased by 30 %, and the power transfer capacity increased by about 17 to 30 times in voltage conversion characteristics.

New Design Method of Wireless Power Transfer System Using Loop Antennas (루프 안테나를 이용한 무선 전력 전송 시스템의 새로운 설계법)

  • Kim, Hee-Seung;Won, Do-Hyun;Lim, Jae-Bong;Jang, Byung-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.36-45
    • /
    • 2010
  • In this paper, we propose a new design method to design a wireless power transfer system using loop antennas for consumer electronics. This method can simply design a wireless power transfer system only using measurements of coupling coefficients and simple equations of equivalent circuit model about loop antennas without complicated electromagnetic analysis. Using the proposed design method, a wireless power transfer system with a pair of loop antennas operating at the frequency of 13.56 MHz, which have a dimension of $50{\times}50\;cm^2$, is designed and implemented. The input return loss, coupling coefficient, efficiency, and input impedance variation with respect to a distance between loop antennas were measured. The proposed design method provides good agreements between measured and predicted results. Also, the wireless power transfer system with impedance matching circuits designed by the proposed design method shows two times higher efficiency characteristics than the case with the general $50\;{\Omega}$ impedance matching circuits. Therefore, we verified that our design method could be an effective tool to design a wireless power transfer system.