Abstract
In this paper, surface transfer impedance measurement of RF cables according to IEC(International Electrotechnical Commission) Standard 96-1 is described and surface transfer impedance of a commercial RF cable is obtained from the measured voltage and scattering parameter with a triaxial fixture fabricated in the operating frequency range from 1 MHz to 30 MHz.
본 논문에서는 IEC(International Electrotechnical Commission) Standard 96-1에 규정된 RF 케이블의 표현전달 임피던스 측정법을 설명하고, 1 MHz ~ 30MHz 동작주파수범위에서 설계 제작된 triaxial fixture를 사용해 전압 및 산란계수를 측정하여 상용 RF 케이블의 표면전달 임피던스를 얻었다.