• Title/Summary/Keyword: 임플란트 형태

Search Result 195, Processing Time 0.023 seconds

Importance of subgingival contour of anterior mandibular region with narrow space (공간이 협소한 하악 전치부에서 치은하 형태(Subgingival contour)의 중요성)

  • Jungsam, Lee
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.4-10
    • /
    • 2022
  • A lack of space can be a key challenge when restoring lower anterior teeth using implants, especially for proper implant placement and the limitation on suitable implant selections. Moreover, depending on the shape of the prosthetic, the adjacent teeth and bone around the implant can also have a significant impact, while in certain cases, the implant can have a detrimental effect on the surrounding bone. Therefore, this case series highlights how variations in the subgingival contour can produce different results for the biology of the marginal bone around an implant and the interproximal bone of the adjacent teeth.

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

Analysis of thermal changes in bone by various insertion torques with different implant designs (서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구)

  • Kim, Min-Ho;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Seok;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.168-176
    • /
    • 2011
  • Purpose: This study aims at investigating the influence of various insertion torques on thermal changes of bone. A proper insertion torque is derived based on the thermal analysis with two different implant designs. Materials and methods: For implant materials, bovine scapula bone of 15 - 20 mm thickness was cut into 35 mm by 40 - 50 mm pieces. Of these, the pieces having 2 - 3 mm thickness cortical bone were used as samples. Then, the half of the sample was immersed in a bath of $36.5^{\circ}C$ and the other half was exposed to ambient temperature of $25^{\circ}C$, so that the inner and surface temperatures reached $36.5^{\circ}C$ and $28^{\circ}C$, respectively. Two types of implants ($4.5{\times}10\;mm$ Br${\aa}$nemark type, $4.8{\times}10\;mm$ Microthread type) were inserted into bovine scapula bone and the temperature was measured by a thermocouple at 0.2 mm from the measuring point. Finite element method (FEM) was used to analyze the thermal changes at contacting surface assuming that the sample is a cube of $4\;cm{\times}4\;cm{\times}2\;cm$ and a layer up to 2 mm from the top is cortical bone and below is a cancellous bone. Boundary conditions were set on the basis of the shape of cavity after implants. SolidWorks was used as a CAD program with the help of Abaqus 6.9-1. Results: In the in-vitro experiment, the Microhead type implant gives a higher maximum temperature than that of the Br${\aa}$nemark type, which is attributed to high frictional heat that is associated with the implant shape. In both types, an Eriksson threshold was observed at torques of 50 Ncm (Br${\aa}$nemark) and 35 Ncm (Microthread type), respectively. Based on these findings, the Microthread type implant is more affected by insertion torques. Conclusion: This study demonstrate that a proper choice of insertion torque is important when using a specific type of implant. In particular, for the Microthread type implant, possible bone damage may be expected as a result of frictional heat, which compensates for initial high success rate of fixation. Therefore, the insertion torque should be adjusted for each implant design. Furthermore, the operation skills should be carefully chosen for each implant type and insertion torque.

What would we meet for the implant dentistry: A Case Report (임플란트를 하면서 만나게 되는 문제들: 증례보고)

  • Lee, Jung-Sam
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.49-67
    • /
    • 2015
  • Since the implant became the important treatment modality in dentistry, the research and clinical effort to mimic natural tooth appearance have been pursued. While the rehabilitation of mastication and occlusal appearance was focused in the past, more esthetic and functional restoration was preferred recently. To fulfill this demand, the clinicians should consider the axial contour, papilla space, subgingival appearance, as well as the shape of occlusal surface. In the surgery part, there have been significant advances in the adequate formation of bone and soft tissue through the careful reflection on the surgery time and incision. When the dentist has good knowledge about this aspect and passion for the final product, he or she can acquire better results.

Success and survival rate of the implant with crestal sinus lift using S-reamer and gel-type graft material: A retrospective study by more 5-years follow check up (S-reamer와 겔 형태의 이식재를 이용한 치조정 접근법을 통한 상악동 거상술 임플란트의 성공률과 생존율: 5년 이상 추적 관찰을 통한 후향적 연구)

  • Kim, Jong Jin;Cho, Sung Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.23-29
    • /
    • 2020
  • Purpose: The purpose of this retrospective study was to evaluate the method using the S-reamer and gel-type graft material by the success rate and survival rate. Materials and methods: Implantation period was from 2008 to 2014, Follow check up year is 2019. There were 59 patients and 117 implants. All implants were placed in the posterior maxilla with the sinus lift. The patients population consisted of 34 men and 25 women, ranging from 19 to 75 years. The residual bone heights were from 1 mm to 6 mm. Sinus was perforated with S-reamer without membrane tearing and gel type bone graft material was used for membrane lifting and filling the space. all implants were placed simultaneously. Panoramic X-ray was taken. After 5 - 6 months healing period, final prostheses were restored. After more 5-years implant surgery, Panoramic X-ray was obtained and X-ray analysis and clinical examination were performed. Success criteria was referred to a Buser's success critera. All implants were classified to success implant, survival implant, failed implant. A success implant was satisfying success criteria, a survival implant was a implant that was acute infection with suppuration and bone loss, a failed implant was a implant that was mobile, removed. Results: Five implants were removed, and 4 implants had infected with bone loss. Survival rate was 95.7% and success rate was 92.3%. Conclusion: This retrospective study presented that this method with S-reamer and gel-type graft material was a successful treatment without membrane tear in the condition of 1-6 mm residual bone height.

Histomorphometry and Stability Analysis of Loaded Implants with two Different Surface Conditions in Beagle Dogs (하중을 가한 두 가지 표면의 임플란트에 관한 조직형태학적 분석 및 안정성 분석 (비글견을 이용한 연구))

  • Kim, Sang-Mi;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.337-349
    • /
    • 2008
  • Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in delayed loading conditions. A total of 36 solid screw implants (diameter 3.75 mm, length 10mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium Implants served as control. Gold crowns were inserted 3 months. Radiographic assessments and stabilitytests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 1 and 3 months after loading. Histological observations and morphometrical measurements were also performed. Of 36 implants, 32 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (p=0.413) and RFA values. The mean BIC % in the Mg-implants was $54.4{\pm}20.2%$. The mean BIC % in the turned implant was $48.9{\pm}8.0%$. These differences between the Mg-implant and control implant were not statistically significant (P=0.264). In the limitation of this study, bone-to-implant contact (BIC) and bone area of Mg-incorporated oxidized implant were similar to machine-turned implant. The stability analysis showed no significantly different ISQ values and marginal bone loss between two groups. Considering time-dependent bone responses of Mg-implant, it seems that Mg-implants enhanced bone responses in early loading conditions and osseointegrated similarly to cp Ti implants in delayed loading conditions. However, further investigations are necessary to obtain long-term bone response of the Mg-implant in human.

Rapid Prototyping을 이용한 임플란트 생성

  • 방철배;김영호;강석호
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1997.10a
    • /
    • pp.37-40
    • /
    • 1997
  • RP(Rapid Prototyping) 기술은 점점 그 활용범위를 넓혀가는 추세이며, 의료분야에서도 임플란트의 제작등에 RP 기술의 도입이 시도되고 있다. 뼈나 치아 등의 인체부속물들은 속성상 직접 그 형태를 파악하기가 힘들고, 따라서 그 대체물인 임플란트의 제작을 위해 MRI나 CT등의 장비가 사용되고 있다. 의료분야에까지 이르는 RP의 활발한 활용에도 불구하고, 아직 국내에서는 RP에 대한 인식이 부족하고 그 활용에 대한 연구가 거의 없는 상황이다. 본 논문은 MRI, CT등의 2차원 평면데이터로부터 직접 RP 기계의 표준입력화일인 STL 파일을 생성시키기 위한 방법을 제시한다. 그리고 MRI로 스캐닝된 사람의 머리뼈 형상을 삼각메쉬 형태의 STL 파일로 변화하여 RP 기계를 통한 실물 모형 제작이 가능하도록 한 예를 설명하였다.

  • PDF

Implant supported prosthetic rehabilitation of severely atrophic mandible with fixed detachable prosthesis (심하게 흡수된 하악골에서 fixed detachable prosthesis를 이용한 임플란트 지지 보철 수복증례)

  • Lee, Hak-Joo;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.180-186
    • /
    • 2017
  • Implant supported prostheses have improved the quality of lives of totally edentulous patients. However, there are some limitations on the number of implants related to the residual bone level or the economic concern and so on. In this situation, applying fixed detachable prosthesis with bilateral cantilevers can be considered. This clinical report describes implant supported prosthetic rehabilitation of a patient with severe bone resorption. The patient was satisfied and felt comfortable with upper complete denture and lower fixed detachable prosthesis.

Influence of Implant Designs on Initial Stability (임플란트의 형태가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Kim, Chang-Seop;Yun, Mi-Jung;Jeong, Chang-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.47-57
    • /
    • 2010
  • An undisturbed healing process without micromotion at the implant-bone interface is essential for achievement of osseointegration of dental implant. Therefore, initial stability was advocated as prerequisite for successful clinical outcome. Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the effect of design change in implant geometry on initial stability of the implants. The purpose of the current study was to assess the initial stability of various designs of implants when placed into artificial bone materials of varying qualities and shapes of insertion holes. Within the scope of this study, the following results were drawn. Bone quality was major importance to achieve initial stability. Initial stability was higher on GS II which had additional design feature of double thread. With a tapered design of implant such as GS III showed a higher initial stability than straight one. An insertion hole with the similar shape of implant would lead to reduce a compression force on cortical bone and enhance a bone anchorage on cancellous bone.

Surface Modification by Laser Deposition and Femtosecond Laser for Biomedical Applications (레이저증착과 펨토레이저를 이용한 생체의료분야의 표면처리응용)

  • Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.24-24
    • /
    • 2015
  • 최근 생체재료의 개발이 눈부시게 발전되고 생체적합성이 우수한 표면을 요구함에 따라 생체재료의 표면처리에 대한 연구가 활발히 진행되고 있다. Laser Deposition법은 항공기 부품제조 분야에 주로 사용되고 있으며 최근에 오하이오 주립대 타이타늄합금연구센터를 중심으로 표면처리에 관한 연구가 주로 이루어졌다. 특히 이를 이용하여 치과재료의 표면처리에 응용을 시도하였다. 치과에서 응용될 수 있는 경우는 주로 임플란트는 부분 또는 완전 무치악 환자의 보철수복에 사용되는 보철물의 제작등에 사용될 수 있으며 이중에서도 특히 생체용 임플란트의 표면처리응용으로 임플란트와 조직간의 접합성을 개선하는 표면처리법으로 연구되었다. 임플란트의 성공과 실패는 물성적인 측면에서 임플란트의 형태, 표면거칠기 및 표면처리방법, 초기하중 등에 의하여 좌우되며 임플란트 재료에 작용하는 응력차폐는 생체적합성을 좌우하는 큰 요인이 되고 있다. 이를 위하여 저 탄성계수합금을 설계하지만 하중을 버티는 강도가 낮아지는 단점이 있어 레이저증착법을 이용하여 임플란트재료인 Ti6Al4V합금에 탄성계수가 낮은 Ta, Nb등을 코팅하는 방법을 통하여 이를 해결하고자하는 시도가 이루어지고 있다. 이 방법은 최근의 3D 프린팅의 원리가 되고 있다. 따라서 발표에서는 Laser Deposition방법을 이용하여 치의학분야에서 응용되고 있는 예를 강연하고 응용 가능 분야에 대하여 토론 하고자한다. 또한 펨토레이저를 이용하여 생체합금의 표면처리는 생체활성화를 더욱 증진시키며 이를 위하여 많은 연구 수행되고 있다. 본 발표에서는 매식용 합금 표면에 펨토레이저를 이용하여 텍스춰링하여 세포가 잘 성장 할 수 있는 크기의 조절함으로써 기존의 표면처리와는 다른 효과를 얻을 수 있는 장점을 알아본다. 펨토레이저를 이용하면 여러 가지 형태의 텍스춰링이 가능하며 원형, 사각형등등 자유자제로 형태의 묘사가 가능하고 깊이 또한 쉽게 조절할 수 있는 장점이 있다. 지금까지는 표면 개질에 사용되는 레이저는 주로 Nd:YAG 레이저의 파장을 반으로 줄인 녹색레이저 (${\lambda}=532nm$)를 사용하거나, 자외선파장영역의 레이저를 사용하는 경우가 일반적으로 가장 보편화되었다. 이를 이용하여 제조된 Ti합금에 펨토 초(10-15 second) 펄스폭 대역을 갖는 레이저를 이용하여 나노크기의 미세 요철을 표면에 형성한 후, 나노튜브를 형성하여 그 표면특성의 변화를 알아보고 펨토레이저가 의료분야에 적용되고 있는 예를 살펴보고자 한다.

  • PDF