• Title/Summary/Keyword: 임플란트 시스템

Search Result 93, Processing Time 0.03 seconds

Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report (완전 무치악 환자에서 자유 착탈가능 임플란트 지대주를 이용한 임플란트 융합 국소의치 수복증례)

  • Oh, You-Kyoung;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Lee, Hyeon-Jong;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.58-66
    • /
    • 2020
  • Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified into screw-retained and cement-retained type according to the retention type, and each has advantages and disadvantages. The EZ crown system (Samwon DMP, Yangsan, Korea) has a cylinder combined with abutment, and the nickel-titanium spring in this cylinder provides a constant force on the zirconia ball to obtain retention in EZ crown system. In this patient, the natural abutment teeth of the mandibular overdenture was hopeless. We planned implant assisted removable partial denture using anterior implant surveyed prosthesis considering functional and esthetical rehabilitation, cost and patient's needs. When fabricating IARPDs using implant as abutment, we could compensate for the shortcomings of existing implant-supported prosthesis retention type and made the design of removable partial denture easy due to using EZ crown system.

Implant surgery and prosthodontic treatment of Temporomandibular disorder patient combined SERAFIN clear aligner system : Clinical case report (세라핀 투명교정 시스템을 활용한 교합 장애 및 치아 결손 증례의 치료)

  • Won-Gun, Chang
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • Adult patients who need implant and prosthodontic treatment often need treatment to improve the existing occlusion through orthodontic treatment for long-term stable treatment results. However, due to non-aesthetic and uncomfortable orthodontic treatment with orthodontic brackets and wires, many adult patients give up treatment even though they know the need for it. Recently, as digital dentistry has affected all areas of dentistry, clear aligner orthodontic systems have begun to be widely used, and their use is increasing in adults and old-aged people due to the esthetic advantage and convenient oral care. SERAFIN clear aligner system developed in Korea has been developed with the aim of implementing a functional occlusion harmony and is used not only for partial orthodontic treatment but also comprehensive orthodontic treatment. This patient presentation is shown the treatment using SERAFIN clear aligner system for the treatment of patient with TMD, severe extrusion of maxillary second molars, and extracted teeth.

Maxillary cement retained implant supported fixed prosthesis using the millingable Pd-Ag alloy generated by CAD/CAM system: clinical report after two years in service (상악 전부 무치악 환자에서 CAD/CAM 시스템으로 제작되는 Pd-Ag 합금을 이용한 고정성 임플란트 전악 수복 증례)

  • Lee, Jun-Sik;Han, Se-Jin;Choi, Yu-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.71-80
    • /
    • 2014
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption. Therefore, it is should be cautious in making the fixed prostheses that restore the function and the esthetics of the gingiva and teeth. In full mouth rehabilitation, CAD/CAM system makes it possible to fabricate restorations with high precision, regardless of span of the restoration. Recently, Palladium-silver (Pd-Ag) alloy which is highly biocompatible and millingable has been developed to compensate for the shortcomings of the titanium or zirconia. This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a Pd-Ag alloy generated by CAD/CAM system on eleven osseointegrated implants. The occluding surfaces were made of Pd-Ag alloy, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

A 15-year clinical retrospective study of Br${\aa}$nemark implants (Br${\aa}$nemark 임플란트의 15년 임상적 후향 연구)

  • Park, Hyo-Jin;Cho, Young-Ye;Kim, Jong-Eun;Choi, Yong-Geun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: This study was to compare the cumulative survival rate (CSR) of Br${\aa}$nemark machined surface implants and TiUnite$^{TM}$ imlants and to analyze association between risk factors and the CSR of the implants. Materials and methods: A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Br${\aa}$nemark machined and TiUnite$^{TM}$ implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite$^{TM}$ implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (${\alpha}$=.05). Results: Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Br${\aa}$nemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite$^{TM}$ implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Br${\aa}$nemark and Nobel Biocare TiUnite$^{TM}$ during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite$^{TM}$ implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification. Conclusion: Clinical performance of Br${\aa}$nemark machined and TiUnite$^{TM}$ implant demonstrated a high level of predictability. In this study, TiUnite$^{TM}$ implant was more successful than machined implant. The implant CSR was associated with several risk factors.

Mandibular implant supported overdentures with two different mini-implant systems: A case report (두 종류의 임플란트 시스템을 이용한 하악의 미니-임플란트지지 피개의치 수복 증례)

  • Park, Jin-Hong;Lee, Jeong-Yol;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.267-272
    • /
    • 2016
  • This case report describes the treatment of two fully edentulous patients with mini-implant overdentures using different implant systems on narrow mandibular alveolar bone ridge. They were complaining about discomfort and pain wearing mandibular conventional complete dentures caused by insufficient retention. Each patient received four miniimplants in the interforaminal area of the mandible using the non-submerged flapless surgical approach. One-body type implant (Slimline, Dentium, Seoul, Korea) was used for a patient and loaded immediately after surgery. Metal housings of O-ring were attached by direct technique. For the other patient, two-piece type implant (LODI, Zest Anchors, Escondido, CA, USA) was used and impressions were made for attachment connection of the Locator's metal housings after 8 weeks of surgery. Within this case report, mandibular miniimplant overdentures using different implant systems showed improvement of patient satisfaction with favorable peri-implant tissue response 6 months after attachment connection. However, long-term follow-up is needed for further evaluation.

A case report of a surgical guide fabricated via intraoral scanning-based implant planning and wax-based rapid prototyping (구강스캐너를 이용한 임플란트 수술 계획 및 왁스 기반 쾌속조형법으로 제작한 수술용 가이드 증례)

  • Shin, Jong-Hoon;Park, Eun-Jin;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.244-249
    • /
    • 2015
  • With the recent progress of digital technology, the computer guided surgery utilizing a guide template in the placement of implant has been actively performed, and the method employing the intraoral scanner at the implant prosthesis introduced. Fabrication method of the guide template can be largely classified into design-related rapid prototyping (RP) system and vector milling system, and each of the method has its own weakness in the clinical application despite of excellent accuracy. Thus, in this case study, a working model was fabricated by the wax RP technology using images acquired by CBCT and an intraoral scanner, and the metal bushing was picked up with orthodontic resin cast upon the wax model. Using this method, a surgical guide template was fabricated and used in surgery. From this, we could obtain a satisfactory outcome clinically in the implant placement and the fabrication of the final prostheses and thus report this case herein.

Three-dimensional finite element analysis on stress distribution of the mandibular implant-supported cantilever prostheses depending on the designs (임플란트 지지 하악 캔틸레버 보철물의 디자인에 따른 저작압 분산에 관한 삼차원 유한요소 분석)

  • Ban, Jae-Hyurk;Shin, Sang-Wan;Kim, Sun-Jong;Lee, Jeong-Yeol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.70-81
    • /
    • 2009
  • Statement of problem: The position and length of cantilever influence on the stress distribution of implants, superstructure and bone. In edentulous mandible, implant-supported cantilever prostheses that based 4 or 6 implants between mental foramens has been attempted. Excessive bite force loaded at cantilever prosthesis causes bone resorption and breakage of superstructure prosthesis around posterior implants. To complement the cantilever length of conventional prosthesis, In 1992, (McCartney) introduced "cantilever-rest-implant" and Malo reported "All-on-Four" in 2003. Purpose: Analyze and compare the stress distribution of conventional cantilever prostheses with rest implant and All-on-$Four^{TM}$ implant prostheses. Material and method: The external loads(300 N vertically, 75 N horizontally) are applied to first molar area. The stress value, stress distribution and aspect of stress dispersion are analyzed by three-dimensional finite element analysis program, ANSYS ver. 10.0. Results: 1. The rest implant and "All-on-Four" implant system are superior to conventional cantilever prostheses to reduce stress on the bone and the superstructure around implants. 2. The rest implant was of the greatest advantage to stress distribution on bone, implant and superstructure. 3. With same number of implants, distally tilted implants are preferred to conventional cantilever prostheses for reducing the length of cantilever.

Analysis of interest in implant using a big data: A web-based study (빅 데이터를 이용한 임플란트에 대한 관심도 분석: 웹 기반 연구)

  • Kong, Hyun-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.164-172
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze the level of interest that common Internet users have in dental implant using a Google Trends, and to compare the level of interest with big data from National Health Insurance Service. Materials and methods: Google Trends provides a relative search volume for search keywords, which is the average data that visualizes the frequency of searches for those keywords over a specific period of time. Implant was selected as the search keyword to evaluate changes in time flows of general Internet users' interest from 2015 to 2019 with trend line and 6 month moving average. Relative search volume for implant was analyzed with the number of patients who received National Health Insurance coverage for implant. Interest in implant and conventional denture was compared and popular related search keywords were analyzed. Results: Relative search volume for implant has increased gradually and showed a significant positive correlation with the total number of patients (P<.01). Interest in implant was higher than denture for most of the time. Keywords related to implant cost were most frequently observed in all years and related search on implant procedure was increasing. Conclusion: Within the limitations of this study, the public interest in dental implant was gradually increasing and specific areas of interest were changing. Web-based Google Trends data was also compared with traditional data and significant correlation was confirmed.

Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up (완전무치악 환자에서 디지털 가이드 수술 방식을 이용한 무피판절개 임플란트 식립증례: 증례보고 및 5년 추적관찰)

  • Shin, Mi-sun;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.312-320
    • /
    • 2019
  • One of the fastest growing segments of implant dentistry is the utilization of computed tomography (CT) scan data and treatment planning software in conjunction with guided surgery for implant reconstruction cases. Computer assisted planning systems and associated surgical templates have established a predictable, esthetic, functional technique for placing and restoring implants. Especially, a philosophy of restoratively driven implant placement has been generally adopted. Recently, a variety of commercial dental fields have released their scanning and fabricating protocols and methods for restorations. This process is still being investigated and developed for the most precise and predictable outcome. This case report describes a female patient who wanted dental implants in fully edentulous areas. Restoratively driven implant placements were performed with surgical guide and the patient was fully satisfied with the clinical results, and at 5-year post restorative follow-up assessment, both implant and prosthesis were proved clinical success.

Retrospective study on survival rate of 2158 osseointegrated implants placed in 770 patients in Sanbon dental hospital of Wonkwang University (원광대학교 산본치과병원에서 770명의 환자에 식립한 2158개의 골유착성 임플란트의 보철 전 초기 생존율에 관한 후향적 연구)

  • Seon, Hwa-Gyeong;Chee, Young-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.278-288
    • /
    • 2014
  • Purpose: The aim of the study was to evaluate preprosthetic initial survival rate and factors associated with survival of osseointegrated implants placed in edentulous area of maxilla and mandible and to suspect the possible causes leading to failure. Materials and Methods: A total of 2158 endosseous implants that had been inserted between 2004 through 2013 were placed in 770 patients. The clinical comparisons were performed to evaluate implant loss in relation to age and gender of patients, position, system, length and diameter of implant, and bone graft technique. Results: According to position, the survival rates were 98.23% in maxillary anterior site, 96.98% in maxillary posterior site, 97.85% in mandibular anterior site and 98.76% in mandibular posterior site (P < 0.05). According to diameter of implant, the survival rates were 100% under 3.0 mm, 97.09% between 3.0 to 3.5 mm, 98.19% between 3.5 to 4.0 mm and 98.29% between 4.0 to 4.5 mm but relatively lower survival rate was 75% in 5.0 mm-over (P < 0.05). The survival rates of implants were 89.51%, 98.28%, 98.34% and 99.27% in the group with isolated sinus graft, with isolated GBR, with sinus graft and GBR simultaneously and without bone graft, especially (P < 0.05). Conclusion: This study establishes a relationship between survival rate of implant and position, diameter of implant system and bone graft technique. In conclusion, there were low survival rates in maxillary posterior site, in dental implants with wide diameter of 5 mm-over, and in the group with isolated sinus graft.