DOI QR코드

DOI QR Code

Mandibular implant supported overdentures with two different mini-implant systems: A case report

두 종류의 임플란트 시스템을 이용한 하악의 미니-임플란트지지 피개의치 수복 증례

  • Park, Jin-Hong (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medical Center, Korea University) ;
  • Lee, Jeong-Yol (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medical Center, Korea University) ;
  • Ryu, Jae-Jun (Division of Prosthodontics, Department of Dentistry, Anam Hospital, Korea University) ;
  • Shin, Sang-Wan (Department of Prosthodontics, Institute for Clinical Dental Research, Korea University Medical Center, Korea University)
  • 박진홍 (고려대학교 구로병원 임상치의학 연구소) ;
  • 이정열 (고려대학교 구로병원 임상치의학 연구소) ;
  • 류재준 (고려대학교 안암병원 치과 보철학교실) ;
  • 신상완 (고려대학교 구로병원 임상치의학 연구소)
  • Received : 2015.09.16
  • Accepted : 2015.10.26
  • Published : 2016.07.29

Abstract

This case report describes the treatment of two fully edentulous patients with mini-implant overdentures using different implant systems on narrow mandibular alveolar bone ridge. They were complaining about discomfort and pain wearing mandibular conventional complete dentures caused by insufficient retention. Each patient received four miniimplants in the interforaminal area of the mandible using the non-submerged flapless surgical approach. One-body type implant (Slimline, Dentium, Seoul, Korea) was used for a patient and loaded immediately after surgery. Metal housings of O-ring were attached by direct technique. For the other patient, two-piece type implant (LODI, Zest Anchors, Escondido, CA, USA) was used and impressions were made for attachment connection of the Locator's metal housings after 8 weeks of surgery. Within this case report, mandibular miniimplant overdentures using different implant systems showed improvement of patient satisfaction with favorable peri-implant tissue response 6 months after attachment connection. However, long-term follow-up is needed for further evaluation.

본 증례는 치조골의 흡수가 심한 두 명의 완전무치악 환자에서 서로 다른 임플란트 시스템을 이용한 하악의 미니-임플란트 지지 피개의치에 대한 증례보고이다. 두 환자는 하악 의치의 유지력 부족으로 인한 의치 사용시 불편감 및 동통을 주소로 호소하였다. 각각의 환자는 4개의 미니 임플란트를 이공사이에 판막의 거상없이 식립하였다. 첫번째 증례는 미니볼 어태치먼트와 일체형으로 된 미니-임플란트(Slimline, Dentium, Seoul, Korea)를 식립하고 구강내 직접법으로 어태치먼트를 연결하여 즉시하중을 시행하였다. 두번째 증례는 분리형으로 로케이터 어태치먼트와 연결되는 미니-임플란트(LODI, Zest Anchors, Escondido, CA, USA)를 이용하였으며, 임플란트 식립 8주 후 간접법으로 어태치먼트를 연결하였다. 최종 의치 장착 후 6개월 정기검진까지 미니볼과 로케이터 어태치먼트를 이용한 하악의 미니-임플란트 지지 피개의치 증례에서 환자의 전반적인 만족도가 개선되었으며 주목할 만한 합병증 없이 만족할 만한 임상적 결과를 얻었다. 단 추후 지속적인 유지관리 및 장기적인 평가가 더 필요하리라 사료된다.

Keywords

References

  1. Bidra AS, Almas K. Mini implants for definitive prosthodontic treatment: a systematic review. J Prosthet Dent 2013;109:156-64. https://doi.org/10.1016/S0022-3913(13)60035-9
  2. Shatkin TE, Petrotto CA. Mini dental implants: a retrospective analysis of 5640 implants placed over a 12-year period. Compend Contin Educ Dent 2012;33:2-9.
  3. Jofre J, Conrady Y, Carrasco C. Survival of splinted mini-implants after contamination with stainless steel. Int J Oral Maxillofac Implants 2010;25:351-6.
  4. Morneburg TR, Proschel PA. Success rates of microimplants in edentulous patients with residual ridge resorption. Int J Oral Maxillofac Implants 2008;23:270-6.
  5. Elsyad MA, Gebreel AA, Fouad MM, Elshoukouki AH. The clinical and radiographic outcome of immediately loaded mini implants supporting a mandibular overdenture. A 3-year prospective study. J Oral Rehabil 2011;38:827-34. https://doi.org/10.1111/j.1365-2842.2011.02213.x
  6. Maryod WH, Ali SM, Shawky AF. Immediate versus early loading of mini-implants supporting mandibular overdentures: a preliminary 3-year clinical outcome report. Int J Prosthodont 2014;27:553-60. https://doi.org/10.11607/ijp.3845
  7. Allum SR, Tomlinson RA, Joshi R. The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study. Clin Oral Implants Res 2008;19:553-9. https://doi.org/10.1111/j.1600-0501.2007.01395.x
  8. Hasan I, Heinemann F, Aitlahrach M, Bourauel C. Biomechanical finite element analysis of small diameter and short dental implant. Biomed Tech (Berl) 2010;55:341-50. https://doi.org/10.1515/bmt.2010.049
  9. Flanagan D, Mascolo A. The mini dental implant in fixed and removable prosthetics: a review. J Oral Implantol 2011;37:123-32. https://doi.org/10.1563/AAID-JOI-D-10-00052.1
  10. Souza RF, Ribeiro AB, Della Vecchia MP, Costa L, Cunha TR, Reis AC, Albuquerque RF Jr. Mini vs. Standard Implants for Mandibular Overdentures: A Randomized Trial. J Dent Res. 2015;94:1376-84. https://doi.org/10.1177/0022034515601959
  11. Mundt T, Schwahn C, Stark T, Biffar R. Clinical response of edentulous people treated with mini dental implants in nine dental practices. Gerodontology 2015;32:179-87. https://doi.org/10.1111/ger.12066
  12. Dilek O, Tezulas E, Dincel M. Required minimum primary stability and torque values for immediate loading of mini dental implants: an experimental study in nonviable bovine femoral bone. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;105:e20-7. https://doi.org/10.1016/j.tripleo.2007.10.003
  13. Preoteasa E, Mele canu-Imre M, Preoteasa CT, Marin M, Lerner H. Aspects of oral morphology as decision factors in mini-implant supported overdenture. Rom J Morphol Embryol 2010;51:309-14.
  14. Sadig WM. Special technique for attachment incorporation with an implant overdenture. J Prosthet Dent 2003;89:93-6. https://doi.org/10.1067/mpr.2003.6
  15. Nissan J, Oz-Ari B, Gross O, Ghelfan O, Chaushu G. Long-term prosthetic aftercare of direct vs. indirect attachment incorporation techniques to mandibular implant-supported overdenture. Clin Oral Implants Res 2011;22:627-30. https://doi.org/10.1111/j.1600-0501.2010.02026.x
  16. Bidra AS, Agar JR, Taylor TD, Lee C, Ortegon S. Techniques for incorporation of attachments in implant-retained overdentures with unsplinted abutments. J Prosthet Dent 2012;107:288-99. https://doi.org/10.1016/S0022-3913(12)60077-8
  17. Walton JN, Huizinga SC, Peck CC. Implant angulation: a measurement technique, implant overdenture maintenance, and the influence of surgical experience. Int J Prosthodont 2001;14:523-30.

Cited by

  1. Analysis on Wear Phenomenon of Artificial Knee Joint Based on FEM and Mechanical Test vol.19, pp.8, 2018, https://doi.org/10.1007/s12541-018-0142-8