Browse > Article
http://dx.doi.org/10.4047/jkap.2020.58.1.58

Implant-assisted removable partial denture using freely removable abutment in a fully edentulous patient: A case report  

Oh, You-Kyoung (Department of Prosthodontics, School of Dentistry, Pusan National University)
Jeong, Chang-Mo (Department of Prosthodontics, School of Dentistry, Pusan National University)
Yun, Mi-Jung (Department of Prosthodontics, School of Dentistry, Pusan National University)
Lee, So-Hyoun (Department of Prosthodontics, School of Dentistry, Pusan National University)
Lee, Hyeon-Jong (Department of Prosthodontics, School of Dentistry, Pusan National University)
Huh, Jung-Bo (Department of Prosthodontics, School of Dentistry, Pusan National University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.58, no.1, 2020 , pp. 58-66 More about this Journal
Abstract
Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified into screw-retained and cement-retained type according to the retention type, and each has advantages and disadvantages. The EZ crown system (Samwon DMP, Yangsan, Korea) has a cylinder combined with abutment, and the nickel-titanium spring in this cylinder provides a constant force on the zirconia ball to obtain retention in EZ crown system. In this patient, the natural abutment teeth of the mandibular overdenture was hopeless. We planned implant assisted removable partial denture using anterior implant surveyed prosthesis considering functional and esthetical rehabilitation, cost and patient's needs. When fabricating IARPDs using implant as abutment, we could compensate for the shortcomings of existing implant-supported prosthesis retention type and made the design of removable partial denture easy due to using EZ crown system.
Keywords
EZ crown system; Implant surveyed prosthesis; Implant-Assisted removable partial denture; Microlocking abutment system;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Jorge JH, Quishida CC, Vergani CE, Machado AL, Pavarina AC, Giampaolo ET. Clinical evaluation of failures in removable partial dentures. J Oral Sci 2012;54:337-42.   DOI
2 Cho YJ, Suh BH. The use of an implant-supported fixed partial denture as abutment teeth for removable partial denture in edentulous patient: A cases report. Korean Acad Oral Maxillofac Implantol 2017;21:96-108.   DOI
3 Lee YJ, Bae EB, Jeong CM, Lee JJ, Jim JY, Huh JB. Removable partial denture using anterior implant-supported fixed prostheses for edentulous patients: A case report. J Korean Dent Sci 2017;10:87-95.   DOI
4 Na HJ, Kang DW, Son MK. Distal-extension removable partial denture with anterior implant prostheses: Case report. J Dent Rehab App Sci 2011;27:437-47.
5 Pellecchia M, Pellecchia R, Emtiaz S. Distal extension mandibular removable partial denture connected to an anterior fixed implant-supported prosthesis: A clinical report. J Prosthet Dent 2000;83:607-12.   DOI
6 Kourtis SG, Sotiriadou S, Voliotis S, Challas A. Private practice results of dental implants. Part I: survival and evaluation of risk factors-Part II: surgical and prosthetic complications. Implant Dent 2004;13:373-85.   DOI
7 Phillips K, Wong KM. Space requirements for implantretained bar-and-clip overdentures. Compend Contin Educ Dent 2001;22:516-8, 520, 522.
8 Wittneben JG, Joda T, Weber HP, Bragger U. Screw retained vs. cement retained implant-supported fixed dental prosthesis. Periodontol 2000 2017;73:141-51.   DOI
9 Kang SH, Kim SK, Heo SJ, Koak JY, Lee JH, Park JM. Clinical evaluation of the removable partial dentures with implant fixed prostheses. J Korean Acad Prosthodont 2016;54:239-45.   DOI
10 Choi JW, Choi KH, Chae HJ, Chae SK, Bae EB, Lee JJ, Lee SH, Jeong CM, Huh JB. Load-bearing capacity and retention of newly developed micro-locking implant prosthetic system: An in vitro pilot study. Materials (Basel) 2018;11:564.   DOI
11 Choi JW, Lee JJ, Bae EB, Huh JB. Implant-supported fixed dental prosthesis with a microlocking implant prosthetic system: A clinical report. J Prosthet Dent 2019 May 7. pii: S0022-3913(19)30014-9.
12 Choi JW, Song CH, Huh JB. Implant-supported fixed dental prostheses with new retention type using zirconia ball and nickel-titanium spring. Implantol 2019;23:16-24.   DOI
13 Shahmiri R, Das R. Finite element analysis of implant-assisted removable partial dentures: Framework design considerations. J Prosthet Dent 2017;118:177-86.   DOI
14 Wang TM, Leu LJ, Wang J, Lin LD. Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis. Int J Oral Maxillofac Implants 2002;17:231-7.
15 Park JM, Koak JY, Kim SK, Alexander J, Heon SJ. Consideration for the combination treatment of removable partial denture and implant. Implantology 2015;19:104-11.
16 Shahmiri R, Das R, Aarts JM, Bennani V. Finite element analysis of an implant-assisted removable partial denture during bilateral loading: occlusal rests position. J Prosthet Dent 2014;112:1126-33.   DOI
17 Ryu BG, Choi WS, Cho HJ, Kim KK. The use of an implant fixed partial denture as abutment teeth for removable partial denture in unilateral edentulous patient: A cases report. Implantol 2016;20:24-34.
18 Cochran DL. The evidence for immediate loading of implants. J Evid Based Dent Pract 2006;6:155-63.   DOI
19 Gallucci GO, Benic GI, Eckert SE, Papaspyridakos P, Schimmel M, Schrott A, Weber HP. Consensus statements and clinical recommendations for implant loading protocols. Int J Oral Maxillofac Implants 2013 Aug 15.