• Title/Summary/Keyword: 인체감지센서

Search Result 107, Processing Time 0.022 seconds

A standardized procedure on building spectral library for hazardous chemicals mixed in river flow using hyperspectral image (초분광 영상을 활용한 하천수 혼합 유해화학물질 표준 분광라이브러리 구축 방안)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.845-859
    • /
    • 2020
  • Climate change and recent heat waves have drawn public attention toward other environmental issues, such as water pollution in the form of algal blooms, chemical leaks, and oil spills. Water pollution by the leakage of chemicals may severely affect human health as well as contaminate the air, water, and soil and cause discoloration or death of crops that come in contact with these chemicals. Chemicals that may spill into water streams are often colorless and water-soluble, which makes it difficult to determine whether the water is polluted using the naked eye. When a chemical spill occurs, it is usually detected through a simple contact detection device by installing sensors at locations where leakage is likely to occur. The drawback with the approach using contact detection sensors is that it relies heavily on the skill of field workers. Moreover, these sensors are installed at a limited number of locations, so spill detection is not possible in areas where they are not installed. Recently hyperspectral images have been used to identify land cover and vegetation and to determine water quality by analyzing the inherent spectral characteristics of these materials. While hyperspectral sensors can potentially be used to detect chemical substances, there is currently a lack of research on the detection of chemicals in water streams using hyperspectral sensors. Therefore, this study utilized remote sensing techniques and the latest sensor technology to overcome the limitations of contact detection technology in detecting the leakage of hazardous chemical into aquatic systems. In this study, we aimed to determine whether 18 types of hazardous chemicals could be individually classified using hyperspectral image. To this end, we obtained hyperspectral images of each chemical to establish a spectral library. We expect that future studies will expand the spectral library database for hazardous chemicals and that verification of its application in water streams will be conducted so that it can be applied to real-time monitoring to facilitate rapid detection and response when a chemical spill has occurred.

Efficient Multi-spot Monitoring System Using PTZ Camera and Wireless Sensor Network (PTZ 카메라와 무선 센서 네트워크를 이용한 효율적인 다중 지역 절전형 모니터링 시스템)

  • Seo, Dong-kyu;Son, Cheol-su;Yang, Su-yeong;Cho, Byung-lok;Kim, Won-jung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.581-584
    • /
    • 2009
  • Recently, the cameras which used for observation are installed in children protection area and local crime prevention area in order to protect life and property and by its work being recognized and are installed more. Normal cameras have cost problem to observe multiple area and detail, because they can observe only one place. PTZ camera can observe multiple area by moving focus by schedule or remote control, but it can't automatically move the focus of it to the place where event occurred, because it can't recognize the place. In this study, we can monitor multiple area effectively, by installing a wireless sensor node equipped with temperature, lighting, gas and human detection sensor to each area, to monitor many place low-price and actively and to move the focus of PTZ camera to preset position, and send recorded video to the user, when the various sensor data received from wireless sensors in observation area are to be determined abnormal by analyzing. In addition, at night we can record a scene using infrared, but to reduce power consumption of lighting system which are installed to improve resolution, it supplies power to the lighting system when event occurred. So we were able to implement low power green monitoring system.

  • PDF

Development of Lighting Control System Based on Location Positioning for Energy Saving (에너지 절약을 위한 위치측위 기반 조명 제어 시스템 개발)

  • Cho, Kyoung-Woo;Jeon, Min-Ho;Oh, Chang-Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.2968-2974
    • /
    • 2014
  • When lighting has installed indoor, we control lighting using human-detecting sensors for people who pass at night and places that are lack of quantity of light. However, malfunction can be caused by positions of inappropriate sensors, and in the case of passages of big buildings, it is a problem that even after a person pass, light apparatuses are turned on for a long time. In this paper, we propose lighting control system based on location positioning for energy saving that control lighting in accordance with passers's position through indoor location positioning. This system use the fingerprinting technology that is one of the location positioning technologies and RSSI data that is collected by a smart device. Using those, it can turn on only lightings that are included in the positioned location and reduce unnecessary power consumption. As a result of experiment, on condition that four people were existing and illumination was 308 lux, we assured reduction effect of 49 Wh.

A Study on Real-Time Sports Activity Classification & Monitoring Using a Tri-axial Accelerometer (가속도 센서를 이용한 실시간 스포츠 동작 분류.모니터링에 관한 연구)

  • Kang, Dong-Won;Choi, Jin-Seung;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.59-64
    • /
    • 2008
  • D. W. KANG, J. S. CHOI, and G. R. TACK, A Study on Real-Time Sports Activity Classification & Monitoring Using a Tri-axial Accelerometer. Korean Jouranl of Sport Biomechanics, Vol. 18, No. 2, pp. 59-64, 2008. This study was conducted to study the real-time sports activity classification and monitoring using single waist mounted tri-axial accelerometer. This monitoring system detects events of sports activities such as walking, running, cycling, transitions between movements, resting and emergency event of falls. Accelerometer module was developed small and easily attachable on waist using wireless communication system which does not constrain sports activities. The sensor signal was transferred to PC and each movement pattern was classified using the developed algorithm in real-time environment. To evaluate proposed algorithm, experiment was performed with several sports activities such as walking, running, cycling movement for 100sec each and falls, transition movements(sit to stand, lie to stand, stand to sit, lie to sit, stand to lie and sit to lie) for 20 times each with 5 healthy subjects. The results showed that successful detection rate of the system for all activities was 95.4%. In this study, through sports activity monitoring. it was possible to classify accurate sports activities and to notify emergency event such as falls. For further study, the accurate energy consumption algorithm for each sports activity is under development.

The Detection of Magnetic Properties in Blood and Nanoparticles using Spin Valve Biosensor (스핀밸브 바이오 센서를 이용한 혈액과 나노입자의 자성특성 검출)

  • Park, Sang-Hyun;Soh, Kwang-Sup;Ahn, Myung-Cheon;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.3
    • /
    • pp.157-162
    • /
    • 2006
  • In this study, a high sensitive giant magnetoresistance-spin valve (GMR-SV) bio-sensing device with high linearity and very low hysteresis was fabricated by photolithography and ion beam deposition sputtering system. Detection of the Fe-hemoglobin inside in a red blood and magnetic nanoparticles using the GMR-SV bio-sensing device was investigated. Here a human's red blood includes hemoglobin, and the nanoparticles are the Co-ferrite magnetic particles coated with a shell of amorphous silica which the average size of the water-soluble bare cobalt nanoparticles was about 9 nm with total size of about 50 nm. When 1 mA sensing current was applied to the current electrode in the patterned active GMR-SV devices with areas of $5x10{\mu}m^2 $ and $2x6{\mu}m^2 $, the output signals of the GMRSV sensor were about 100 mV and 14 mV, respectively. In addition, the maximum sensitivity of the fabricated GMR-SV sensor was about $0.1{\sim}0.8%/Oe$. The magnitude of output voltage signals was obtained from four-probe magnetoresistive measured system, and the picture of real-time motion images was monitored by an optical microscope. Even one drop of human blood and nanopartices in distilled water were found to be enough for detecting and analyzing their signals clearly.

Design and Implementation of Healthcare System Based on Non-Contact Biosignal Measurement (비접촉 생체신호 측정 기반 헬스케어 시스템 설계 및 구현)

  • Hong, Seong-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.185-190
    • /
    • 2020
  • The rapid aging is increasing as the shortage of medical facilities and the resulting of decline in the quality of public health. In order to ease the burden of rising medical expenses, advanced medical institutions are expanding their remote medical care to lower the cost of services. U-healthcare detects the changes in physical and chemical phenomena occurring in the human body and converts them into electrical signals that can be processed and feeds back to the results through analytical and visualization processes to select only the desired information from the measured signals. The service is provided through a process of providing an alarm to a user. However, traditional biometric methods of attaching sensors directly to the body can be annoying and rejected in daily life. Therefore, there is a need for a method of continuously measuring biometric information without causing inconvenience to daily life. In this paper, we propose an IR-UWB-based non-contact and non-responsive respiratory measurement system that can continuously monitor biological information without any inconveniences to daily life.

A Study on the CSMA/CA Performance Improvement based IEEE 802.15.6 (IEEE 802.15.6 기반 CSMA/CA 성능 향상에 관한 연구)

  • Lee, Jung-Jae;Kim, Ihn-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.11
    • /
    • pp.1225-1230
    • /
    • 2015
  • MAC protocol for WBAN performs CSMA/CA(:Carrier Sense Multiple Access with Collision Avoidance)algorithm that handles traffic which occurs in emergency with top priority in order to deal with variable data of sensor node for medicine. Emergency message that node sends undergoes collision and delay of transmission by retransmission of emergency message and waste of energy by retransmission. This paper suggests algorithm that minimizes loss of frame caused by collision and applies different backoff parameters by setting order of priority between MAC instruction frame and data frame in CSMA/CA algorithm case which applies order of priority queuing to improve aforementioned problem. According to performance evaluation, it has been found that using suggested MAC protocol showed lower collision probability, higher packet transmission processing ratio and lower packet loss compared with using IEEE 802.15.6.