• Title/Summary/Keyword: 인장실험

Search Result 1,993, Processing Time 0.033 seconds

A Experimental Study on the Stabilizing Effect of Anchors against Sliding (사면에 설치된 앵커의 활동억지효과에 대한 실험적 연구)

  • Song, Young-Suk;Hong, Won-Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.171-180
    • /
    • 2006
  • To investigate the stabilizing effect of anchors against sliding, a series of the model test was carried out. An apparatus was developed to perform the model test of the slope reinforced by anchors. An instrumentation system has been applied on the anchors to measure the axial force during slope failure. The maximum stabilizing effect is revealed about 0.5% of the area ratio. The initial loss of anchor force is represented about 24% of initial jacking force. This result is equaled to the proposed range(10%~25%) of the field test result(Yun, 1997). The effective jacking force corresponds to 70% of the initial jacking force. Therefore, the initial jacking force should be determined more than 30% of the design jacking force. As the initial jacking force becomes increase, the reinforced slope is transferred to brittle failure behavior due to increasing the density of slope soils.

Analysis and Test for Turn-buckle of Capacity for Measuring Tensile Force (용량별 인장력 측정용 턴버클의 해석 및 실험)

  • Shin, Kyung-Jae;Lee, Swoo-Heon;Lee, Hee-Du
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.715-724
    • /
    • 2011
  • A turn buckle inserted between tension members that sustain the structural loads in a suspension structure system is a device that is capable of adjusting the tensile force. The tension member is an important element of a tension structure, but no simple and economical method of measuring a tensile force applied to members has been proposed yet. Thus, a turn buckle for measuring the tensile force in a tension member was developed in this study. The turn buckles of the measurement limit loads of 100kN, 200kN, and 300kN were tested through a theoretical analysis and a finite element analysis. There was no significant difference in the results of the theoretical analysis, FEA, and the test. In addition, the ultimate strength of the turn buckle using FEA showed that a new turn buckle is sufficiently safe to use even when there is a five-times overload in the measurement limit load.

A Comparison of Residual Tensile Properties of GFRP Reinforcing Bar at High Temperature and after Exposure to High Temperature (고온과 고온노출 후 GFRP 보강근의 잔존인장성능 비교)

  • Kim, Seongdo;Moon, Doyoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.77-84
    • /
    • 2015
  • Tensile tests were conducted on the GFRP reinforcement exposed to high temperature. The exposure condition for this study was below $200^{\circ}C$ for about 3 minutes. This conditioning is minor compared with that presented in experimental program conducted by other researchers. The residual tensile strength and elastic modulus of GFRP reinforcing bars at high temperature and after exposure to high temperature were compared. In results, tensile properties were decreased at high temperatures, but those after exposure to high temperature were recovered to pre-heating level almost completely. These results could be valuable for evaluating GFRP reinforced structure damaged by fire accident.

Experimental Study on Fatigue Characteristics of Domestic Reinforcing Bars (국산철근의 피로특성에 관한 실험적 연구)

  • 변근주;노병철;송하원
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.177-187
    • /
    • 1997
  • 철근 콘크리트 구조부재는 철근과 콘크리트로 구성된 합성부재이므로, 철근콘크리트 구조부재의 피로강도는 철근과 콘크리트 고유의 피로특성에 따라 변화하게 된다. 철근자체의 피로특성은 철근의 정적강도 특성과 상이함으로, 실험을 통하여 규명할 필요가 있다. 본 논문에서는 대표적인 국내 2개사에서 생산되는 철근에 대하여 직접인장 피로실험을 실시하여 이들의 피로특성을 규명하였으며, 철근콘크리트 휨부재 내부의 철근 피로특성과 철근만의 직접인장 피로특성의 비교 분석으로부터 직접인장 피로실험만으로 철근콘크리트 휨부재의 피로특성을 평가할 수 있음을 밝혔다. 또한 반복하중을 받는 철근콘크리트 부재의 피로점토를 위한 기준을 제시하였다.

Tensile Behavior of Polyetylene Fiber-Reinforced Cementless Composite (폴리에틸렌섬유 보강 무시멘트 복합재료의 인장 거동)

  • Lee, Bang Yeon;Choi, Jeong-Il;Kim, Young-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5600-5607
    • /
    • 2015
  • This study investigated experimentally the tensile behavior of polyetylene fiber-reinforced cementless composite. Four types of polyetylene fiber-reinforced cementless composite were designed. The water to binder ratio was 0.30-0.38, and the amount of polyetylene fiber was 1.75 vol%. A series of experiments including uniaxial tension, density, and compression tests were performed to evaluate the performance of the composites. From the test results, it was exhibited that the composite has superior tensile performance such as high tensile strength and tensile strain capacity compared with other types of composites.

Constitutive Law of Reinforced Concrete Subjected to Biaxial Tension (2축 인장을 받는 철근콘크리트의 구성방정식)

  • Cho, Jae-Yeol;Kim, Nam-Sik;Cho, Nam-So;Choun, Young-Sun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.69-77
    • /
    • 2003
  • One directional and biaxial tension tests of 13 reinforced concrete panels were conducted to derive a constitutive law of concrete. Based on the test results, a model equation is derived for the stress-strain relationship of concrete in tension. Main test variables are reinforcement ratio and the load ratio applied in two directions. In addition a failure envelope of concrete in tension-tension region is suggested based on the initial crack occurrence. Test results show that the concrete carries substantial tensile stress even after cracking occurrence. However, the application of this proposed stress-strain relationship for concrete is limited to the case where the direction of reinforcement coincides with the direction of the applied principal stresses.

Mechanical Properties of Slag-Based Cementless Composites According to Types of Polyethylene Fibers (폴리에틸렌 섬유 종류에 따른 고로슬래그 기반 무시멘트 복합재료의 역학특성)

  • Jin, Jeong-Eon;Choi, Jeong-Il;Park, Se-Eon;Lee, Bang Yeon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.243-251
    • /
    • 2022
  • The purpose of this study is to investigate experimentally the effect of polyethylene fibers with different tensile strength and aspect ratio on the properties of cementless composite. Three types of mixtures according to the types of polyethylene fibers and water-to-binder ratio were prepared and density, compressive strength and tension tests were performed. Test results showed that the mixture reinforced by polyethylene fiber with a low tensile strength by 10 % and a high aspect ratio by 8.3 % had a high tensile strain capacity by 11.7 %, a high toughness by 12.4 %, and a low crack width by 9.1 %. It was also observed that high tensile strain capacity and better cracking pattern could be achieved by increasing the water-to-binder ratio of composite although its strength is low.

Effect of Aspect Ratio in Direct Tensile Strength of Concrete (콘크리트 직접인장강도의 세장비 효과)

  • Hong, Geon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.246-253
    • /
    • 2003
  • Although concrete members are not normally designed to resist direct tension, the knowledge of tensile strength is of value in estimating the cracking load. In general, there are three types of test method for tensile strength ; direct tension test, flexural tension test, and splitting tension test. Though direct tensile strength represents the real tensile strength of concrete, direct tension tests are seldom carried out, mainly because it is very difficult to applicate a pure tension force. The purpose of this paper is to investigate the test methods, effect of aspect ratio, and the size effect on the direct tensile strength. Direct tension test, using bonded end plates, follows RILEM and U.S.Bureau of Reclamation. And other test methods follow ASTM provisions. Four kinds of aspect ratio and two kinds of size effect are tested. Same variables are tested by direct tension test and splitting tension test for comparison between the two test methods. Test results show that direct tensile strength of concrete is more affected by aspect ratio and size than other kinds of strength.

Effects of Curing Conditions on Compressive Strength and Tensile Behavior of Alkali-Active Slag-Based Fiber Reinforced Composites (양생 조건이 알칼리 활성 슬래그 기반 섬유보강 복합재료의 압축강도와 인장거동에 미치는 영향)

  • Park, Se-Eon;Choi, Jeong-Il;Lee, Bang Yeon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.260-267
    • /
    • 2021
  • The purpose of this study was to experimentally investigate the effects of curing methods on the compressive strength and tensile behavior of alkali-activated slag-based fiber-reinforced composite with a water-to-binder ratio of 15%. Three kinds of mixtures according to the curing conditions were prepared and compressive strength and tension tests were performed. Test results showed that the compressive strength and the first cracking strength of composites decreased when high temperature curing and air curing were adopted, while tensile strain capacity of composites increased. It was also observed that crack spacing and crack width of composites decreased by applying high temperature and air curing.

Study on Fastened Properties by Applied to CFRP Laminates of Subminiature Screw (초소형나사의 CFRP 적층판 적용에 따른 체결특성에 관한 연구)

  • Choi, Byung Hui;Kim, Ho Joong;Kim, Ji Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1239-1243
    • /
    • 2014
  • This paper presents the application of carbon-fiber-reinforced polymer (CFRP) for the damage absorption and optimal design of portable smart devices to close in life. CFRP specimens are subjected to a tensile test to estimate their mechanical properties in terms of the stacking angles. Further, the screw reverse torque and screw torque at each stacking angle are determined using a torque tester after tapping holes on the CFRP specimens. Two experiments are performed for comparing their results in order to determine optimal conditions. In the tensile test, a woven specimen is found to have the highest strength and stiffness. In the case of the woven specimen, no difference is observed even when it is applied to prevent loosening of the coating. And average result value was excellent.