• Title/Summary/Keyword: 인상평가

Search Result 239, Processing Time 0.024 seconds

The Impression Evaluation d the Dress's Wearer in Relation to Neutral Tone, Skirt Width and Length Variation (무채색의 톤과 스커트 폭.길이 변화에 따른 원피스드레스 착용자의 인상평가)

  • Chio, Su-Kyung;Kang, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.13 no.2
    • /
    • pp.317-328
    • /
    • 2004
  • The purpose of this study was to identify the effect of three clothing cues(neutral tone, skirt width, and skirt length of dress) on the impressions of females. The experimental materials developed for this study were a set of stimuli and response scales. The stimuli were 20 color pictures manipulated with three clothing cues by drawing. The 7-point scale designed for visual evaluation of impression formation about females included 29 bipolar adjectives. The subjects were 240 undergraduate female students in Chinju city. The results of this study were as follows: By analyzing the impression of female figures by neutral tone, skirt width, and length, five factors including ability.activity, elegance, attractiveness, concentration of attention, and tenderness were identified. Among these factors, ability.activity and elegance were proved to be more important. Each impression of neutral tone with skirt width. length have significant effects on tenderness. Each impression of skirt width.length with neutral tone have significant effects on ability.activity.

  • PDF

The Impression Evaluation of the Hat's Wearer According to Types of Hat design, Hair-style and Hair-length (모자유형과 헤어스타일 및 길이변화에 따른 모자착용자의 인상평가)

  • Jeong Su-Jin;Jeong Hae-Son;Kang Kyung-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.7 no.3
    • /
    • pp.129-144
    • /
    • 2005
  • The purpose of this research was to find out the effect of hair-style(straight and wave), hair-length(short, medium and iong), and type of hat design(no-hat, beret, cloche, bowler and capeline) on the impressions of hat's wearer . The experimental materials developed for this study were a set of stimulus and response scales(7-point scale semantic). Thirty stimuli color pictures of various combination of hair length, hair style, and type of hat design were manipulated by computer drawing. The subjects were 360 undergraduate students in Seoul, Kyunggi and Kyungnam. The result of this study can be summarized as follows; Impression factor of the stimulus consisted of the 5 different dimensions (attractiveness, gracefulness, brightness, visibilty, cuteness). Each impression of type of hat design, along with hair-style, hair-length had significant effects on gracefulness, visibilty and cuteness. Each impression of hair-style, hair-length, along with type of hat design had significant effects on gracefulness, brightness, visibilty and cuteness. Thus type of hat design, hair-style and hair-length have a significant influence on the impression evaluation of hat's wearer.

  • PDF

Physical Features of Faces and Personal Personality Impression (얼굴의 물리적 특성과 성격인상)

  • 조경덕
    • Science of Emotion and Sensibility
    • /
    • v.7 no.2
    • /
    • pp.195-201
    • /
    • 2004
  • This study investigated the relationship between the physical features and personality impression of faces. Subjects were exposed to male and female facial photographic images. Using 7-points scales, subjects were asked to rate 31 personality traits. The three factors extracted from factor analysis were labeled social desirability, activity, and intelligence. The analysis of correlation between physical features and factor scores of faces indicated that there is a significant correlation between features of eye of male faces and intelligence and between features of chin of female faces and intelligence and social desirability. These results suggested that subjects judged the personality impression, based on different physical features in male and female feces.

  • PDF

Performance Analysis of Smart Automatic Jack-Up System Using the Pairwise Comparison Matrix Analysis Method (쌍대비교행렬 분석 기법을 적용한 스마트 자동 인상 시스템의 성능 분석)

  • Kim, Sung-Jo;Ji, Yongsoo;Kim, Bongsik;Han, Tong-Seok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.1
    • /
    • pp.9-14
    • /
    • 2022
  • In this study, a smart jack-up system was developed to prevent safety accidents by performing risk analysis when a structure is lifted for maintenance. A quantitative risk analysis program that can analyze the risk using the pairwise comparison matrix analysis method was developed. The risk was analyzed in real-time for the lifting structure by connecting the program with an automatic jack-up system. Displacements were measured by the IR sensor among the components of the automatic jack-up system, and the displacements were provided to the quantitative risk analysis program. To confirm the performance of the smart automatic jack-up system, experiments were conducted on bridge and risk analysis was performed when a superstructure was lifted. A linear variable differential transformer (LVDT) was also installed on the bridge to verify the performance of the smart automatic jack-up system. The maximum displacements were measured using the devices, and the declinations were compared. The performance of the simultaneous operation of the jack-up device was verified by the analysis of variance (ANOVA).

Precision Evaluation of Scanning the Digital Dental Abutment Impression and Dental Gypsum Model according to 3-dimensional Superimposing Different Skills (3차원 중첩 기술 차이에 따른 디지털 치과용 지대치 인상체 및 경석고 모형의 스캐닝 정밀도 평가)

  • Jeon, Jin-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.12
    • /
    • pp.639-645
    • /
    • 2018
  • The objective of this research was to compare the precision of scanning the digital abutment impression and gypsum model according to 3-dimensional superimposing different skills. There were made with the abutment impression and gypsum model of a maxillary 1st premolar, blue light scanner scanned to obtain the stereolithography (STL) file. After the same process was performed 10 more times without moving them on the scanner table about the abutment impression and gypsum model, respectively (n=11, per types). By superimposing the date of scanning the abutment impression and gypsum model used with no control and best-fit-alignment skills, 10 color-difference maps and root mean square (RMS) data were obtained. The independent t-test was performed to compare RMS data between the each other groups (${\alpha}=0.05$). In the scanning abutment impressions, $RMS{\pm}SD$ of no control, best-fit-alignment showed $6.86{\pm}0.94$, $5.04{\pm}0.24$. in the scanning gypsum model, $4.98{\pm}1.16$, $3.39{\pm}0.07$, all groups showed a significant difference (P<0.001). Trough the this study's result, not only best-fit-alignment but no control is used with digital dental computer-aided design/computer-aided manufacturing (CAD/CAM) research and clinical part.

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Effect of interproximal undercut on the dimensional accuracy of impression (치간 유두 소실로 인한 언더컷이 인상체의 체적 정확도에 미치는 영향)

  • Lee, Ju-Ri;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.330-336
    • /
    • 2015
  • Purpose: This study evaluated the effect of loss of interproximal papilla, creating an undercut, on the accuracy of impression materials. Materials and methods: Two addition type silicone impression materials ($Extrude^{(R)}$ Speed Wash, $Imprint^{TM}$ II Quick Step Light Body) and one alginate impression material (Cavex Impressional) were used to make impressions of a maxillary master model simulating clinical conditions with or without interproximal papilla. Stone was poured in the impressions and working casts were fabricated. A total of 6 groups with 6 working casts in each group were scanned using 3-dimensional optical scanner. The accuracy of the impressions was assessed by measuring the dimensional changes (${\Delta}I$ (%)) of 6 distances on working casts compared to a master model with a 3-dimensional digitizing and inspection software. The data were analyzed by two-way ANOVA (P<.05). Results: Three of 6 distances showed statistically significant differences among the impression materials. Only 1 of 6 distances in alginate impression showed a statistically significant difference between casts with and without interproximal papilla (P=.047). Conclusion: The presence of undercut due to loss of interproximal papilla did not significantly influence the dimensional accuracy of addition type silicone and alginate impression materials.

A Qualitative Study on Social Work Applicants' Impression Management Tactics in Job Interviews (사회복지 지원자의 채용면접 인상관리전략에 관한 질적 연구)

  • Jang, Yeon-Jin;Jeong, Sun-Wuk
    • Korean Journal of Social Welfare
    • /
    • v.60 no.1
    • /
    • pp.77-102
    • /
    • 2008
  • The purpose of this study is to know what impression management(IM) tactics social work applicants use in their job interviews and what relation between their IM tactics and interviewers' evaluation exists. To accomplish this purpose, we reviewed the precedent researches about IM and conducted a qualitative study with the applicants in a community welfare center which adopted open approach in recruitment process. We analyzed the applicants' IM tactics through observing video-taped interview sessions and reviewing interviewers' rating paper. The results showed that the social work applicants mainly used self-promotion tactic for emphasizing their strengths and justification tactics for expressing their weaknesses. Some applicants often used fit-with-organization and other-enhancement belonged to ingratiation tactics. According to interviewers' rating results, the applicants with deep eye contact, calm attitude or smiling face gave a good impression to the interviewers. In the final discussion, an applicant who adopted diverse verbal and non-verbal tactics and expressed her point clearly was perceived attractive by the interviewers and accepted as the best choice. Based on this qualitative analysis, we have made several practical suggestions for social work applicants, social work researchers and social work organizations.

  • PDF

A study on the impression and expression tendency of the sankei kanseino poster by Ikko Tanaka (타나카 잇코(Tanaka Ikko) 산케이칸세이노(산경관세능(産經觀世能)) 포스터의 인상과 표현경향에 관한 연구)

  • Cho, Hyung-Soo;Ha, Sang-O;Kawachi, Tomoki
    • Archives of design research
    • /
    • v.20 no.1 s.69
    • /
    • pp.89-100
    • /
    • 2007
  • This research is accompanied with Tanaka's works in order to consider the result from the evaluation of his works through an impression analysis and his expression trendency. The nine posters are chosen for appraisal among a series of Kanseino Poster which Ikko Tanaka drew under the sponsorship of Sankei Newspaper. The reason why those posters are selected is that the structure is strong and simple comparatively. Tanaka Ikko's poster works can be generously explained with three factors through a factor analysis. Considering his works in all cluster analysis, in the first group, he makes a good use of traditional materials and his works have a powerful image. In the second group, a geometric figure is arranged simply and a modern image is strong. In the third group, the traditional materials express a modern image. As mentioned above, the mood of his works can be summarized as follows. $\ulcorner$His works have updated the Japanese image from traditional to modern$\lrcorner$.

  • PDF

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.