DOI QR코드

DOI QR Code

Precision Evaluation of Scanning the Digital Dental Abutment Impression and Dental Gypsum Model according to 3-dimensional Superimposing Different Skills

3차원 중첩 기술 차이에 따른 디지털 치과용 지대치 인상체 및 경석고 모형의 스캐닝 정밀도 평가

  • 전진훈 (경동대학교 치기공학과)
  • Received : 2018.10.08
  • Accepted : 2018.11.14
  • Published : 2018.12.28

Abstract

The objective of this research was to compare the precision of scanning the digital abutment impression and gypsum model according to 3-dimensional superimposing different skills. There were made with the abutment impression and gypsum model of a maxillary 1st premolar, blue light scanner scanned to obtain the stereolithography (STL) file. After the same process was performed 10 more times without moving them on the scanner table about the abutment impression and gypsum model, respectively (n=11, per types). By superimposing the date of scanning the abutment impression and gypsum model used with no control and best-fit-alignment skills, 10 color-difference maps and root mean square (RMS) data were obtained. The independent t-test was performed to compare RMS data between the each other groups (${\alpha}=0.05$). In the scanning abutment impressions, $RMS{\pm}SD$ of no control, best-fit-alignment showed $6.86{\pm}0.94$, $5.04{\pm}0.24$. in the scanning gypsum model, $4.98{\pm}1.16$, $3.39{\pm}0.07$, all groups showed a significant difference (P<0.001). Trough the this study's result, not only best-fit-alignment but no control is used with digital dental computer-aided design/computer-aided manufacturing (CAD/CAM) research and clinical part.

본 연구의 목적은 3차원 중첩 기술 차이에 따른 디지털 치과용 지대치 인상체 및 경석고 모형의 스캐닝 정밀도를 비교 평가하는 것이다. 상악 제1 소구치 지대치 인상체와 경석고 모형를 제작했다. 청색광 스캐너로 스캔하여 stereolithography (STL)을 얻었다. 지대치 인상체와 경석고 모형에 대하여 스캐너 테이블에서 이동하지 않은 채로 10번의 추가 스캔을 수행하였다. no control과 best-fit-alignment 기술을 사용하여 지대치 인상체와 경석고 모형 스캐닝 데이터를 중첩시킴으로써 10개의 color-difference maps과 root mean square (RMS) 데이터를 얻었다. 서로 간의 그룹 사이에 RMS data를 가지고 독립 t 검정을 수행하였다(${\alpha}=0.05$). 지대치 인상체 스캐닝에 있어서 no control과 best-fit-alignment의 RMS${\pm}$StandardDeviation (SD) 값은 $6.86{\pm}0.94$, $5.04{\pm}0.24$로 나타났고, 경석고 모형 스캐닝에 있어서는 $4.98{\pm}1.16$, $3.39{\pm}0.07$로 나타났으며, 모든 그룹 간에 유의한 차이를 보였다(P<0.001). 본 연구 결과를 통해 best-fit-alignment뿐만 아니라 no control은 디지털 치과캐드캠 연구 분야 및 임상 분야에 활용될 수 있다고 생각한다.

Keywords

CCTHCV_2018_v18n12_639_f0001.png 이미지

그림 1. Schematic diagram of this research

CCTHCV_2018_v18n12_639_f0002.png 이미지

그림 2. 3-dimensional scan data

CCTHCV_2018_v18n12_639_f0003.png 이미지

그림 3. Qualitative comparison data utilized with three-dimensional color-difference-map of abutment impression and stone model; no control versus best-fit-alignment

표 1. Comparisons RMS±SD (㎛) Quantitative Values of Discrepancies of Scanning Abutment Tooth Impression and Stone Model according to Three-dimensional Superimposing Different Skills (n=10, respectively)

CCTHCV_2018_v18n12_639_t0001.png 이미지

References

  1. L. Sun, J. S. Lee, H. H. Choo, H. S. Hwang, and K. M. Lee, "Reproducibility of an intraoral scanner: A comparison between in-vivo and ex-vivo scans," Am J Orthod Dentofacial Orthop, Vol.154, No.2, pp.305-310, 2018. https://doi.org/10.1016/j.ajodo.2017.09.022
  2. R. Nedelcu, P. Olsson, I. Nyström, J. Ryden, and A. Thor, "Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: A novel in vivo analysis method," J Dent, Vol.69, No.2, pp.110-118, 2018. https://doi.org/10.1016/j.jdent.2017.12.006
  3. J. H. Jeon, B. Y. Choi, C. M. Kim, J. H. Kim, H. Y. Kim, and W. C. Kim, "Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners," J Prosthet Dent, Vol.114, No.4, pp.549-553, 2015. https://doi.org/10.1016/j.prosdent.2015.04.019
  4. I. Hamanaka, K, Isshi, and Y. Takahashi, "Fabrication of a nonmetal clasp denture supported by an intraoral scanner and CAD-CAM," J Prosthet Dent, Vol.120, No.1 pp.9-12, 2018. https://doi.org/10.1016/j.prosdent.2017.09.011
  5. B. Yilmaz, E. Kale, and W. M. Johnston, "Marginal discrepancy of CAD-CAM complete-arch fixed implant-supported frameworks," J Prosthet Dent, Vol.120, No.1, pp.65-70, 2018. https://doi.org/10.1016/j.prosdent.2017.11.021
  6. J. H. Jeon, D. Y. Kim, J. J. Lee, J. H. Kim, and W. C. Kim, "Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner," J Adv Prosthodont, Vol.8, No.3, pp.214-218, 2016. https://doi.org/10.4047/jap.2016.8.3.214
  7. J. H. Jeon, I. D. Jung, J. H. Kim, H. Y. Kim, and W. C. Kim, "Three-dimensional evaluation of the repeatability of scans of stone models and impressions using a blue LED scanner," Dent Mater J, Vol.34, No.5, pp.686-691, 2015. https://doi.org/10.4012/dmj.2014-347
  8. S. Fukazawa, C. Odaira, and H. Kondo, "Investigation of accuracy and reproducibility of abutment position by intraoral scanners," J Prosthodont Res, Vol.61, No.4, pp.450-459, 2017. https://doi.org/10.1016/j.jpor.2017.01.005
  9. B. Yilmaz, F. A. Alshahrani, E. Kale, and W. M. Johnston, "Effect of feldspathic porcelain layering on the marginal fit of zirconia and titanium complete-arch fixed implant-supported frameworks," J Prosthet Dent, Vol.120, No.1, pp.71-78, 2018. https://doi.org/10.1016/j.prosdent.2017.11.003
  10. I. D. Jeong, J. J. Lee, J. H. Jeon, J. H. Kim, H. Y. Kim, and W. C. Kim, "Accuracy of complete-arch model using an intraoral video scanner: An in vitro study," J Prosthet Dent, Vol.115, No.6, pp.755-759, 2016. https://doi.org/10.1016/j.prosdent.2015.11.007
  11. H. Hayama, K. Fueki, J. Wadachi, and N. Wakabayashi, "Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible," J Prosthodont Res, Vol.62, No.3, pp.347-352, 2018. https://doi.org/10.1016/j.jpor.2018.01.003
  12. R. Okada, M. Asakura, A. Ando, H. Kumano, S. Ban, T. Kawai, and J. Takebe, "Fracture strength testing of crowns made of CAD/CAM composite resins," J Prosthodont Res, Vol.62, No.3, pp.287-292, 2018. https://doi.org/10.1016/j.jpor.2017.10.003
  13. B. Yilmaz, "CAD-CAM high-density polymer implant-supported fixed diagnostic prostheses," J Prosthet Dent, Vol.119, No.5, pp.688-692, 2018. https://doi.org/10.1016/j.prosdent.2017.06.022
  14. P. Ausiello, S. Ciaramella, A. Fabianelli, A. Gioria, M. Martorelli, A. Lanzotti, and D. C. Watts, "Mechanical behavior of bulk direct composite versus block composite and lithium disilicate indirect Class II restorations by CAD-FEM modeling," Dent Mater, Vol.33, No.6, pp.690-701, 2017. https://doi.org/10.1016/j.dental.2017.03.014
  15. C. M. Kim, J. H. Jeon, J. H. Kim, H. Y. Kim, and W. C. Kim, "Three-dimensional evaluation of the reproducibility of presintered zirconia single copings fabricated with the subtractive method," J Prosthet Dent, Vol.116, No.2, pp.237-241, 2016. https://doi.org/10.1016/j.prosdent.2015.10.027
  16. M. Moser, R. Schmid, R. Schindel, and G. Hildebrandt, "Patient-specific polymethylmethacrylate prostheses for secondary reconstruction of large calvarial defects: A retrospective feasibility study of a new intraoperative moulding device for cranioplasty," J Craniomaxillofac Surg, Vol.45, No.2, pp.295-303, 2017. https://doi.org/10.1016/j.jcms.2016.11.016
  17. L. Liu, H. Li, Y. Cui, R. Li, F. Meng, Z. Ye, and X. Zhang, "Calcium Channel Opening Rather than the Release of ATP Causes the Apoptosis of Osteoblasts Induced by Overloaded Mechanical Stimulation," Cell Physiol Biochem Vol.42, No.2, pp.441-454, 2017. https://doi.org/10.1159/000477592
  18. B. Vecsei, G. Joos-Kovacs, J. Borbely, and P. Hermann, "Comparison of the accuracy of direct and indirect three-dimensional digitizing processes for CAD/CAM systems - An in vitro study," J Prosthodont Res, Vol.61, No.2, pp.177-184, 2017. https://doi.org/10.1016/j.jpor.2016.07.001
  19. T. V. Flugge, S. Schlager, K. Nelson, S. Nahles, and M. C. Metzger, "Repeatability of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner," Am J Orthod Dentofacial Orthop, Vol.144, No.3 pp.471-478, 2013. https://doi.org/10.1016/j.ajodo.2013.04.017
  20. M. Martorelli, P. Ausiello, and R. Morrone, "A new method to assess the accuracy of a cone beam computed tomography scanner by using a non-contact reverse engineering technique," J Dent, Vol.42, No.4, pp.460-465, 2014. https://doi.org/10.1016/j.jdent.2013.12.018