• Title/Summary/Keyword: 인상용 트레이

Search Result 10, Processing Time 0.028 seconds

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Comparative accuracy of implant impression techniques with different splinting materials (임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교)

  • Ki-Yoon Hong;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • Purpose: We investigated the effect of open tray impression using pick-up impression coping and close tray impression using transfer impression coping on the accuracy of impression in edentulous patients on their mandibular parts. the effect of material types of pick-up type impression copings for splinting in open tray impression on the accuracy of impression was also evaluated. Materials and Methods: Two implant fixtures were implanted in parallel in the left molar of the mandibular in the shape of a mandibular partial edentulous model. The 40 individual trays were fabricated using 3D printer. The prepared individual trays were classified into 4 groups (i.e., PN, PG, PH, and TN groups), and a total of 40 impression-takings were conducted. A master cast was connected to a Scan Body. The converted STL file was super-imposed on the scan images of the various groups. Results: The order of standard deviation values decreased as follows: PN (0.2343 ± 0.0844 mm), TN (0.2192 ± 0.0840 mm), indicating that the high accuracy of impression for TN group. In addition, for the comparison results between the material types used in splinting the open tray impression, the PH group showed a relatively lower standard deviation (0.1910 ± 0.1176 mm) than that of the PN group (0.2343 ± 0.0844 mm), PG group (0.2556 ± 0.1082 mm). Conclusion: The acrylic resin synthesized by light-induced polymerization exhibited a higher accuracy of impression taking than that of autopolymerizing acrylic resin. Meanwhile, the accuracy of impression taking was not dependent on the implant impression taking method or the presence of connection/fixation of impression copings.

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

Fitness of Adjustable Dental Impression Trays on the Caucasian and African American (백인과 흑인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Park, Yong-Suck;Kim, Yu-Lee;Oh, Sang-Cheon;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.185-192
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Caucasian and African American. Material and methods: The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. Sixty Caucasian (male:30, female:30) and sixty African American (male:30, female:30) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. Results: 1. Uniform impression material width was achieved by controling the width of the tray using stops and beveled guides. 2. In the maxillary tray on the Caucasian, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 13.0 mm. 3. In the maxillary tray on the African American, the impression material thickness was measured to be rather great showing thickness of the midpalatal part 12.0 mm, posterior palatal part 11.0 mm and the labial frenum width was 11.0 mm. 4. In the maxillary tray on the African American, the impression material width of posterior border (0.8 mm) was measured to be small. 5. In the mandibular tray on the Caucasian, the impression material width was measured (2.7-6.7 mm) and posterior border width (2.1 mm) was measured small. The impression material length was measured (2.8-6.7 mm). 6. In the mandibular tray on the African American, the impression material width was measured to be rather great showing width of the labial frenum 9.2 mm and the width of posterior border was measured too small (0.3 mm). Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Caucasian and African American, we can take more easy and accurate dental impressions.

Accuracy of 5-axis precision milling for guided surgical template (가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구)

  • Park, Ji-Man;Yi, Tae-Kyoung;Jung, Je-Kyo;Kim, Yong;Park, Eun-Jin;Han, Chong-Hyun;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.294-300
    • /
    • 2010
  • Purpose: The template-guided implant surgery offers several advantages over the traditional approach. The purpose of this study was to evaluate the accuracy of coordinate synchronization procedure with 5-axis milling machine for surgical template fabrication by means of reverse engineering through universal CAD software. Materials and methods: The study was performed on ten edentulous models with imbedded gutta percha stoppings which were hidden under silicon gingival form. The platform for synchordination was formed on the bottom side of models and these casts were imaged in Cone beam CT. Vectors of stoppings were extracted and transferred to those of planned implant on virtual planning software. Depth of milling process was set to the level of one half of stoppings and the coordinate of the data was synchronized to the model image. Synchronization of milling coordinate was done by the conversion process for the platform for the synchordination located on the bottom of the model. The models were fixed on the synchordination plate of 5-axis milling machine and drilling was done as the planned vector and depth based on the synchronized data with twist drill of the same diameter as GP stopping. For the 3D rendering and image merging, the impression tray was set on the conbeam CT and pre- and post- CT acquiring was done with the model fixed on the impression body. The accuracy analysis was done with Solidworks (Dassault systems, Concord, USA) by measuring vector of stopping’s top and bottom centers of experimental model through merging and reverse engineering the planned and post-drilling CT image. Correlations among the parameters were tested by means of Pearson correlation coefficient and calculated with SPSS (release 14.0, SPSS Inc. Chicago, USA) ($\alpha$ = 0.05). Results: Due to the declination, GP remnant on upper half of stoppings was observed for every drilled bores. The deviation between planned image and drilled bore that was reverse engineered was 0.31 (0.15 - 0.42) mm at the entrance, 0.36 (0.24 - 0.51) mm at the apex, and angular deviation was 1.62 (0.54 - 2.27)$^{\circ}$. There was positive correlation between the deviation at the entrance and that at the apex (Pearson Correlation Coefficient = 0.904, P = .013). Conclusion: The coordinate synchronization 5-axis milling procedure has adequate accuracy for the production of the guided surgical template.

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.

Difference of perception of the duties of dental hygienist between dentists and dental hygiene students in an area (일개 지역 치과의사와 치위생학과 학생 간 치과위생사의 업무에 대한 인식의 차이)

  • Hwang, Soo-Jeong;Koong, Hwa-Soo;Lee, Sang-Hoon
    • Journal of Korean Academy of Dental Administration
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • Although dental hygienists have performed chair-side assisting and other dental cares as well as preventive dental cares in Korea, medical technician law confines duties of dental hygienists as closed narrative. The aim of this study was to investigate difference in perception of duties of dental hygienists in dental clinic between dentists and dental hygiene students. A total of 245 copies of questionnaires were distributed to dentists and students by post-mail. Only 42 dentists and 30 students in an area replied these questionnaires about the present and future duties of dental hygienists after providing written consent. Both groups agreed that intra and extra oral X-ray taking, education about oral health behavior, instruction after dental treatment, chair-side assisting, consulting for patients, scaling, initial impression taking, management of dental materials and equipment, sterilization of equipment, and receiving dental bills are duties of dental hygienists. However, they had different perceptions about various dental treatments as duties of dental hygienists even if they were under instructions of a dentist, including infiltration anesthesia, filling in cavity, intramuscular injection, FC change, canal irrigation, orthodontic treatment including separating, ligature bracket bonding and removing, setting crown and bridge, making individual, removing implant screw, and so on. These findings demonstrated that there were different perceptions about duties of dental hygienists between dentists and dental hygiene students, especially on dental treatment.