• Title/Summary/Keyword: 이온 전극

Search Result 874, Processing Time 0.034 seconds

Study of Lithium Ion Capacitors Using Carbonaceous Electrode Utilized for Anode in Lithium Ion Batteries (이차전지 음극용 탄소 전극을 이용한 리튬이온 커패시터 연구)

  • Oh, Rye-Gyeong;Hong, Jung-Eui;Yang, Won-Geun;Ryu, Kwang-Sun
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.489-493
    • /
    • 2013
  • The most common carbonaceous anode materials of lithium ion batteries (natural graphite, artificial graphite, hard carbon, and mesocarbon microbeads) were utilized as an electrode in lithium ion capacitors. It could be able to enhance the energy density of capacitors due to the intercalation of lithium ion. In this work, the properties of capacitors using the symmetric electrode were measured by organizing coin cell typed capacitors. Also, we made other capacitors having pre-intercalated lithium ions at one side of the electrode. The results of electrochemical measurements for these capacitors show that the storage capacitance was appeared. In other words, if the migration of lithium ions is supplied continuously in the electrolytes, lithium ions can be diffused into the carbonaceous materials. And it results in the improvement of capacitance compared to only using symmetric carbonaceous electrodes. Also, we conducted the same measurement with graphene oxide having a the large specific area in the same condition. Herein, we recognized that the large specific area is extremely important for supercapacitors.

Potential of Perchlorate Ion-Selective Electrode in PVC Membrane and Electrode Characteristics by ac Impedance (과염소산 이온선택성 PVC막 전극전위와 임피던스에 의한 전극특성)

  • 김경민;조경섭;강안수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.49-52
    • /
    • 1998
  • 1. 서론 : 화약이나 고체 충진제, 고체로\ulcorner 추진제의 산화제, slurry blasting agent 및 동물사료의 식품첨가제로 사용되고 있는 과염소산은 발화나 폭발성이 매우 강한 산화제로 정확한 순도를 측정하는 것은 중요하다. 용량분석법과 중량분석법에 비교하여 조작이 간단하고 편리한 과염소산이온의 농도를 직접 측정할 수 있는 PVC막 전극에 대한 많은 연구가 진행되고 있다. (생략)

  • PDF

Enhancement of the Cell Performance for an Carbon Anode in Li-ion Battery (수지 코팅에 의한 리튬이온전지용 탄소 부극재료의 전지 성능 개선)

  • 김정식;윤휘영;유광수
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.8
    • /
    • pp.755-760
    • /
    • 2001
  • 본 연구에서는 카본전극의 표면개질에 따른 리튬이온 전지의 전지특성 변화에 대해서 연구하였다. 즉, mesocarbon microbeads(MCMB) 카본에 에폭시 수지(resin)를 코팅시킴으로서 카본전극 표면에 개질시켰으며, 이에 따른 전극의 전기화학적 특성을 고찰하였다. 에폭시 수지에 의한 카본의 표면코팅은 30%의 H$_2$SO$_4$용액에서 2시간 동안 refluxing한 MCMB를 에폭시 수지를 용해시킨 THF(tetrahydrofuran) 용액에 넣어 혼합함으로써 MCMB 표면에 에폭시 수지가 코팅되도록 하였다. 이렇게 에폭시 수지가 코팅된 MCMB를 약 1000-130$0^{\circ}C$로 열처리하여 고분해능 투과전자현미경으로 관찰한 결과, 코팅층은 비정질 카본 구조를 갖게됨을 알 수 있었다. 또한, 에폭시 수지에 의하여 코팅된 MCMB는 코팅되지 않은 MCMB보다 더 높은 BET 비표면적을 나타내었다. Li/MCMB 전지 cell을 만들어 충방전시험을 수행한 결과, 에폭시 수지에 의하여 코팅된 MCMB로 만든 전극이 더 우수한 충방전 용량과 싸이클 특성을 나타내었다. 에폭시 수지 코팅으로 전극 표면을 개질시킴으로서 전지특성이 개선된 원인에 관하여 에폭시 코팅의 결정구조와 전극계면에서의 부동태 피막(passivation film) 형성과 연계하여 논의하였다.

  • PDF

Poly-3,4-dihydroxybenzoic Acid Film Electrodes Modified with Dopamine for Determination of Ti(IV) Ions (도파민으로 수식된 3,4-dihydroxybenzoic acid 고분자 피막전극을 이용한 Ti(IV)이온의 정량)

  • Cha, Seong-Keuck
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.130-133
    • /
    • 2003
  • 3,4-dihydroxybenzoic acid(3,4-DHBA) was electropolymerized on glassy carbon electrode to give the GC/p-3,4-DHBA type electrode which was modified with dopamine by the help of 1-(3-dimethylaminopropyl)-3-ethyl carbodiimide hydrochloride(EDC) acting as a coupling agent. The carboxylic sites on the polymeric surface of p-3,4-DHBA and mine group at the dopamine gave a QCA(Au)/p-3,4-DHBA-dopamine type of modified electrodes. The o-quinone moieties at the electrode surface exhibited high selectivity to titanium ions in solution. The redox process of the electrode is hydroquinone : quinone +$2H^+2e^-$, which had two strong and two weak pairs of peaks at CV. The modified electrode can deposit Ti(IV) ions as much as $4.13\times10^{-5}gcm^{-2}$. The calibration curve of the electrodes, log of the surface coverage-normalized redox response vs log[Ti], exhibited an excellent correlation$(r{\geq}0.997)$ for titanium concentrations ranging from $5.25\times10^{-4}\;to\;5.25\tiems10^{-8}M.$.

Potentiometric Response of Chitin - based Membrane Electrode to various Metal cations (키틴 막 전극의 양이온에 대한 감응 연구)

  • Choi, Bun-Hong;Yun, Young-Ja
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.235-242
    • /
    • 1998
  • Membrane electrode based on chitin(po1y-[$1{\rightarrow}4$]-${\beta}$-N-acetyl-D-glucosamine) was prepared by mixing uniformly grounded of chitin (100 mesh) with PVC and DOS. We investigated the potential response of chitin membrane electrode to metal ions. It was observed that the response slopes for $Cd^{2+}$(34.9 mV/decade) and $Cu^{2+}$(34.0 mV/decade) were larger than those for other ions in pH 4 acetate buffer. The potentiometric response of chitin electrode to varying pH was nearly constant in the pH range of 2~12.

  • PDF

Determination of Copper(II) ion with a nafion-ethylenediamine modified glassy carbon electrode (내피온-에틸렌디아민이 수식된 유리탄소전극으로 구리(II) 이온의 정량)

  • Ko, Young Chun;Kim, Hee Cheol
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.213-218
    • /
    • 2007
  • Copper(II) ion was measured with the use of a perfluorinated sulfonated polymer-ethylenediamine (nafion-en) modified glassy carbon electrode. The electrode mechanism was based on the chemical reactivity of an immobilized layer (nafion-en) to yield complex $[Cu(en)_2]^{+2}$. The reduction potential peak by differential pulse voltammetry(DPV) was observed at -0.4402V(${\pm}0.0050V$) (vs. Ag/AgCl). The linear calibration curve was obtained from $1.0{\times}10^{-6}$ to $1.0{\times}10^{-4}M$ copper(II) ion concentration, and the detection limit(3s) was $1.96{\times}10^{-6}M$.

K+ Ion-Selective PVC Membrane Electrodes with Neutral Carriers (중성운반체를 이용한 K+ 이온선택성 PVC막 전극)

  • Kim, Yong-Ryul;Cho, Kyoung-Sub;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.734-741
    • /
    • 1998
  • Electrode characteristics were studied in the interface between sample solutions and $K^+$ ion selective PVC membrane electrodes containing neutral carriers, dibenzo-18-crown-6(D18Cr6) and valinomycin(Val). The effect of doping of base electrolytes, the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, and concentration variation of sample solution on the response characteristics of electrode such as the measured Nernstian slope, the detection limit, the linear response range, and potentiometric selectivity coefficients, were studied. In order to synthesize the membrane D18Cr6 and Val as neutral carriers were used, and complex between the carrier and $K^+$ ions were used as active materials. PVC membrane electrodes were made of plasticizers (DBP, DOS, and DBS), the base electrolyte[potassium tetraphenylborate(KTPB)], and solvent(THF). The chemical structure of carrier D18Cr6 was best for electrode and ideal electrode characteristics were appeared especially in case of doping of TPB. The optimum carrier content was about 3.23 wt % in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the electrode characteristics was improved. But its characteristics were lowered below the optimum membrane thickness because of the elution of carrier, deterioration of membrane strength, etc. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were in the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

Lead Ion-Selective Electrode Based on Upper-rim Calix[4]crown Ionophore (캘릭스[4]크라운 유도체를 이온선택성 물질로 사용한 납이온 선택성 막전극)

  • Namgung, Miok;Ihm, Hye-Jae;Paek, Kyung-Soo;Yun, Young-Ja
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.2
    • /
    • pp.115-119
    • /
    • 2000
  • A PVC membrane electrode based on upper-rim calix[4] crown as ionophore was prepared using dioctyl sebacate (DOS) as a plasticizer. The potential response of this membrane electrode to alkali, alka-line earth and transitionmetal metal cations were examined. This membrane electrode exhibited a Nernstian response to $10^{-6}{\sim}10^{-2}M\;Pb(NO_3)_2$ with a slope ot 27.0 mV/decade. Its response time ($t_{90}$) was 10s and it could be used for at least 2 months. Also, the potential was maintained constantly in the rage of ph $2.0{\sim}12$.

  • PDF

Stability Characteristics of Sn Species Behavior on Surface of a Sn-modified Pt Electrode for Electrolytic Reduction of Nitrate Ion (질산염 이온의 전해 환원을 위한 Sn-modified Pt 전극 표면에서의 Sn 안정성 거동 특성)

  • Kim, Kwang-Wook;Kim, Seong-Min;Kim, Yeon-Hwa;Lee, Eil-Hee;Jee, Kwang-Yong
    • Korean Chemical Engineering Research
    • /
    • v.45 no.5
    • /
    • pp.433-441
    • /
    • 2007
  • This work investigated the stability of a Sn-modified Pt electrode, which was used for reduction of nitrate, fabricated by an adsorption or electro-deposition of Sn on Pt. In order to find the causes for instability of the electrode, the effects of the solutions in which the electrode was used and the potential applied to the electrode on the electrochemical and metallurgical behaviors of Sn on Pt were studied. The Sn of freshly- prepared modified-Sn Pt electrode existed as Sn hydroxide form, which brought about an easy loss of the electro-activity of the electrode even staying in water, especially in acid solution. When the Sn-modified Pt electrode was used for the reduction of nitrate, the electro-activity of the electrode was affected depending on the potential applied to the electrode. When a more negative potential than the redox equilibrium potential between $Sn(OH)_2$ and Sn was applied to the electrode, the Sn hydroxide was converted to Sn that could diffused into Pt, which leaded to the loss of electro-activity of the electrode as well. The solid diffusion of Sn increased linearly with the applied potential. The Sn-electrodeposited Pt electrode which had more Sn on the electrode was more favorable to maintaining the integrity of the electrode during the reduction of nitrate than the Sn-adsorbed Pt electrode prepared in the under-potential deposition way.