• Title/Summary/Keyword: 응력회복

Search Result 176, Processing Time 0.037 seconds

Creep Prediction of Chemical Grouted Sands (약액주입 사질고결토의 크리프 예측)

  • Kang, Hee-Bog;Kim, Jong-Ryeol;Kang, Kwon-Soo;Kim, Tae-Hoon;Hwang, Soung-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.2
    • /
    • pp.195-204
    • /
    • 2004
  • A series of constant creep and repeated creep tests are performed to investigate the behavior of visco-elasto-plastic materials of chemical grouted sands. In the result of constant creep test, the material exhibits three types of shear strain : elastic, plastic, viscoelastic. The elastic, plastic and viscoelastic strains are linear, i.e., the strains are proportional to the stresses for loading. Good agreement is found between the predicted viscoelastic and test results by the power law and the generalized model. In the repeated creep test, the instantaneous recoverable strain is time-independent and the magnitude of accumulated plastic strain increases with number of cycles. Also it is seen that the accumulated plastic strains are approximately proportional to stress. There are no significant differences between test results predicted values for first cycle, and the differences increase relatively insignificantly with number of cycles.

Numerical Study on Flexural Strength of Reinforced Concrete members Exposed to Fire (가열조건에 따른 철근콘크리트 부재의 휨 강도에 관한 해석적 연구)

  • 이상호;허은진
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.195-205
    • /
    • 2001
  • This Paper describes a numerical method to evaluate the flexural strength of reinforced concrete members exposed to fire. An analytical method is developed for the moment-curvature relationship for the cross section which is subjected to high temperature. The method performs heat-transfer analysis for the cross sections and subsequently performs numerical analysis using the stress-strain relationships of concrete and reinforcing steel in various heat conditions. The results of the numerical studies are ; 1) the residual flexural strength exposing at high temperature is affected by the heating time, the depth of concrete cover and reinforcement ratio, 2) the residual flexural strength after exposed at high temperature is recovered of its original strength at minimum ratio of reinforcement, while members having half of maximum ratio and maximum ratio of reinforcement do not recover its original strength, 3) furthermore, the concrete may reach its maximum capacity before reinforcement yields in reinforced concrete members having maximum ratio of reinforcement.

Finite Element Analysis of Stress Distribution around the Micro-Patterned Implants (마이크로패터닝을 부여한 임플란트 주변골에서의 하중 분포에 관한 유한요소분석법적 연구)

  • Hur, Bae-Young;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.67-76
    • /
    • 2008
  • Implant requires long lasting, strong osseointegration using bio-mechanical interlocking by bone ingrowth. In regarding the size level for bone ingrowth, the micro-patterning would enhance bone response. Micro-patterning can increase the area contacting the bone tissues. Therefore, it may distribute the load to the surrounding bone tissue, more effectively. This study compared and analyzed the load distributing effect with the shape and number of micro-patterning. For the optimal comparison of threads, the assumptions different from general finite element analysis model were made. It was assumed that the implant was axisymmetric and infinitely long. The implant was assumed to be completely embedded in the infinitely long cortical bone and to have 100% bone apposition. The implant-bone interface had completely fixed boundary conditions and received an infinitely big axial load. The condition of threads were as follows. The reference model 1 had conventional thread. Model 2 had 2 micro-patterns on the upper flank of the thread. Model 3 had 2 micro-patterns on the lower flank of the thread. Model 4 had 2 micro-patterns on the upper and lower flanks of the thread. Model 5 had 3 micro patterns on the upper and lower flanks of the thread. The results were as follows: 1. The thread with micro-patterns distributed stress better than the conventional thread. 2. The thread with micro-patterns on the lower flank distributed stress better than that with micro-patterns on the upper flank. 3. The thread with 3 micro-patterns distributed stress better than that with 2 micro-patterns, However, an area with stress concentration occurred.

Three Dimensional Finite Element Analysis on Stress Distribution According to the Bucco-lingual Inclination of the Implant Fixture and Abutment in the Mandibular Posterior Region (하악 구치부에서 임플란트 고정체와 지대주의 협설 기울기에 따른 응력분포에 관한 삼차원 유한요소 분석)

  • Lee, Hyun-Sook;Kim, Ji-Youn;Kim, Ye-Mi;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.371-392
    • /
    • 2011
  • The purpose of this study was to comparatively analyze the stress distribution according to the inclinations of abutments and angulations of the implant fixtures under occlusal loading force. Three study models with straight and $15^{\circ}$ and $25^{\circ}$-angled abutments were prepared following the insertion of Implants parallel to the long axis of the tooth. Additional two experimental models were fabricated with $15^{\circ}$ and $25^{\circ}$ fixture inclinations. Using ANSYS 11, a finite element analysis program, the magnitudes of stress distribution were analyzed. The magnitude of stress under loading was lowest when the load was applied vertically onto the axis of implant. And the magnitude of stress under compound(vertical+oblique) loading was increased as the inclination of implant abutment and fixture was increase. But, the distribution of stress was different as the loading conditions, because of the horizontal offset. As the offset between the axis of loading and the central axis of the implant increased, the stress was increased.

Effects of Coronal Thread Pitch in Scalloped Implant with 2 Different Connections on Loading Stress using 3 Dimensional Finite Element Analysis (연결부 형태가 다른 두 가지 scallop 임플란트에서 경부 나사선 피치가 응력 분포에 미치는 영향 : 삼차원적유한요소분석)

  • Choi, Kyung-Soo;Park, Seong-Hun;Lee, Jae-Hoon;Huh, Jung-Bo;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.111-118
    • /
    • 2013
  • Purpose of present study is to investigate the effects of thread pitch in coronal portion in scalloped implant with 2 different connections on loading stress using 3 dimensional finite element analysis. Scalloped implant with 4 different thread pitches (0.4mm, 0.5mm, 0.6, and 0.7mm) in the coronal part was modeled with 2 different implant-abutment connections. Platform matching connection had the same implant and abutment diameter so that they were in flush contact at the periphery while platform mismatching connection had smaller abutment diameter than implant so that their connection was made away from periphery of implant-bone interface. Occlusal loading of 100N force was applied vertically and 30 degree obliquely to all 8 models and the maximum von Mises bone stress was identified. Loading stress as highly concentrated in cortical bone. Platform mismatching scalloped implant with small thread pitch (0.4mm) model had consistently lowest maximum von Mises bone stress in vertical and oblique loads. Platform matching model had lowest maximum von Mises bone stress with 0.6mm thread pitch in vertical load and with 0.4mm thread pitch in oblique load. Platform mismatching connection had important roles in reducing maximum von Mises bone stress. Scalloped implant with smaller coronal thread pitch showed trend of reducing maximum von Mises bone stress under load.

Ideal Body Modeling of Rock Frost-thawing (이상물체를 이용한 암반의 동결융해 Modeling)

  • Han, Heuisoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.12
    • /
    • pp.5-11
    • /
    • 2010
  • If the groundwater in rock joint is changed into ice, it induces the stress increment by volume increase. Also, if the ice is changed into groundwater again, the stress in joint decreases by volume decrease. The accumulated displacement and fatigues of joints are increased by the stress-hysterisis, induced from the continuous frost-thawing. Also the shear strength is decreased by them continuously. The stress-hysterisis is affected by the atmospheric temperature changes, whose behavior is visco-elasticity, usually. Therefore, Kelvin model could be used to analyze the frost-thawing behavior in winter. The measured data of total 5 points are examined, which are composed of 3 points of shallow joints and 2 points of deep joints. Because shallow weathered rocks have many joints, a lot of Kelvin model are connected and the behaviors are complicated. In case of deep joints, simple Kelvin model is applied and the behaviors are also simple.

Redeveloping Turbelent Boundary Layer after Separation-Reattachment(II) -A Consideration on Turbulence Models- (박리-재부착 이후의 재발달 난류경계층 II -난류 모델들에 관한 고찰-)

  • 백세진;유정열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.999-1011
    • /
    • 1989
  • A consideration on the trubulence models for describing the redeveloping turbulent boundary layer beyond separation-reattachment in the flow over a backward-facing step is given through experimental and numerical studies. By considering the blance among the measured values of respective terms in the transport equations for the turbulent kinetic energy and the turbulent shear stress, the recovering process of the redeveloping boundary layer from non-equilibrium to equilibrium has been investigated, which takes place slowly over a substantial distance in the downstream direction. In the numerical study, the standard K-.epsilon. model and the Reynolds stress model have been applied to two kinds of flow regions, one for the entire downstream region after the backward-facing step and another for the downstream region after reattachment. Then the results are compared to a meaningful extent, with the experimental values of the turbulent kinetic energy k, the turbulent energy production term P, the dissipation term K-.epsilon. model, a necessity for a new modelling has been brought forward, which can be also applied to the case of the nonequlibrium turbulent flow.

Three-Dimensional Finite Element Analysis for Comparison between Titanium Implant Abutment and Zirconia Implant Abutment (지르코니아 임플란트 지대주와 티타늄 임플란트 지대주의 삼차원적 유한요소응력분석)

  • Yun, Mi-Jung;Kim, Chang-Weop;Jeong, Chan-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.51-61
    • /
    • 2011
  • Recently, restoring implants in the esthetically demanding region, zirconia-based materials are widely used due to their superior mechanical properties, accuracies, and esthetics. The purpose of this study was to investigate the load transfer and mechanical stability of zirconia and titanium implant abutments by using the three-dimensional finite element analysis model. The internal conical joint type and external butt joint type implant system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. An load of 250N was applied vertically beside 3mm of implant axis. Stress distribution of zirconia and titanium implant abutment is similar. The maximum equivalent stress of titanium implant abutment is lower than zirconia implant abutment about 15%. Howevere considering a high mechanical strength that exceed those of titanium implant abutment, zirconia implant abutment had similar mechanical stability of titanium implant abutment clinically.

Stress distribution of implants with external and internal connection design: a 3-D finite element analysis (내측 연결 및 외측 연결 방식으로 설계된 임플란트의 3차원적 유한요소 응력 분석)

  • Chung, Hyunju;Yang, Sung-Pyo;Park, Jae-Ho;Park, Chan;Shin, Jin-Ho;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.189-198
    • /
    • 2017
  • Purpose: This study aims to analyze the stress distribution of mandibular molar restoration supported by the implants with external hex and internal taper abutment connection design. Materials and Methods: Models of external connection (EXHEX) and internal connection (INCON) implants, corresponding abutment/crowns, and screws were developed. Supporting edentulous mandibular bony structures were designed. All the components were assembled and a finite element analysis was performed to predict the magnitude and pattern of stresses generated by occlusal loading. A total of 120 N static force was applied both by axial (L1) and oblique (L2) direction. Results: Peak von Mises stresses produced in the implants by L2 load produced 6 - 15 times greater than those by L1 load. The INCON model showed 2.2 times greater total amount of crown cusp deflection than the EXHEX model. Fastening screw in EXHEX model and upside margin of implant fixture in INCON model generated the peak von Mises stresses by oblique occlusal force. EXHEX model and INCON model showed the similar opening gap between abutment and fixture, but intimate sealing inside the contact interface was maintained in INCON model. Conclusion: Oblique force produced grater magnitudes of deflection and stress than those by axial force. The maximum stress area at the implant was different between the INCON and EXHEX models.

Effect of Implant Designs on Insertion Torque and Stress : Three-Dimensional Finite Element Analysis (임플란트 디자인이 식립 회전력과 응력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Kim, Jang-Eung;Choi, Yu-Sung;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.205-220
    • /
    • 2010
  • Purpose : To analyze the effect of implant designs on insertion torque and stress by performing a comparative study on von Mises stress, torque and normal force through a three-dimensional finite element analysis. Materials and methods : Models of the screw type implant were used to model the implant as a form placed in the mandibular premolar region applying a three-dimensional finite element method. Screw type implant designs were classified into 4 types of parallel ones and 7 types of tapered ones. Other factors were simulated to represent clinical environment. Results : In parallel implant designs, higher and wider threads resulted in higher insertion torques and higher stress distributions. In tapered implant designs, changes in the taper led to remarkable differences in the insertion torques. It was difficult to determine a certain tendency of stress distribution around the implants since the stress level was too high around them. In tapered implant designs, smaller implants demonstrated lower insertion torques than the original type and were relatively less dependent on the degree of taper. Tapered implants showed higher insertion torques and higher stress distributions than parallel implants. Conclusion : According to this study, although the tapered implant demonstrated a higher insertion torque than the parallel implant, stress tended to be concentrated in the entire fixture of the tapered implant due to the inefficient stress distribution.