• Title/Summary/Keyword: 음장

Search Result 451, Processing Time 0.023 seconds

Signal Processing in Medical Ultrasound B-mode Imaging (의료용 초음파 B-모드 영상을 위한 신호처리)

  • Song, Tai-Kyong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.521-537
    • /
    • 2000
  • Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes "main stream" digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing.

  • PDF

A Study on the Sound Quality Improvement Using the Equal Compensation Filter in Bark-scale for the Cross-talk Cancellation (크로스토크 제거를 위한 바크스케일 등가 보상 필터를 이용한 음질 향상에 관한 연구)

  • Kim, Hack-Jin;Kim, Soon-Hyub
    • The KIPS Transactions:PartB
    • /
    • v.11B no.3
    • /
    • pp.345-352
    • /
    • 2004
  • This paper deals a method to deliver more realistic sound by cancelling the cross-talk which is inherent to the 5.1 channel speaker system. The acoustical model for cross-talk cancellation is the free field model. This model minimizes distortion of sound. 1 used the bark scale sound quality compensation which based on psycho-acoustic. For the surround channels, band-limited sound quality compensation is performed in the frequency domain. I also performed the sound qualify assessment test on the traditional 2 channel stereo and 5.1 channel system. This test is performed in the tort chamber which satisfies the ITU-R specifications. 1 uses the IACC(Inter-Aural Cross-Correlation) to determine the preferences of the amateur and the golden ear experts to asses the trans-aural filter. According to the result from the proposed method, I got more the 38dB separation rates with the Dolby standard speaker array. The results on the diffusion by the subjective test with the experts shows 0.4∼0.5 point Increased then before.

Haptic recognition of the palm using ultrasound radiation force and its application (초음파 방사힘을 이용한 손바닥의 촉각 인식과 응용)

  • Kim, Sun Ae;Kim, Tae Yang;Lee, Yeol Eum;Lee, Soo Yeon;Jeong, Mok Kun;Kwon, Sung Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.467-475
    • /
    • 2019
  • A high-intensity ultrasound wave generates acoustic streaming and acoustic radiation forces when propagating through a medium. An acoustic radiation force generated in a three-dimensional space can produce a solid tactile sensation, delivering spatial information directly to the human skin. We placed 154 ultrasound transmit elements with a frequency of 40 kHz on a concave circular dish, and generated an acoustic radiation force at the focal point by transmitting the ultrasound wave. To feel the tactile sensation better, the transmit elements were excited by sine waves whose amplitude was modulated by a 60 Hz square wave. As an application of ultrasonic tactile sensing, a region where tactile sense is formed in the air is used as an indicator for the position of the hand. We confirmed the utility of ultrasonic tactile feedback by implementing a system that provides the number of fingers to a machine by receiving the shape of the hand at the focal point where the tactile sense is detected.

Range Estimating Performance Evaluation of the Underwater Broadband Source by Array Invariant (Array Invariant를 이용한 수중 광대역 음원의 거리 추정성능 분석)

  • Kim Se-Young;Chun Seung-Yong;Kim Boo-Il;Kim Ki-Man
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.305-311
    • /
    • 2006
  • In this paper the performance of a array invariant method is evaluated for source-range estimation in horizontally stratified shallow water ocean waveguide. The method has advantage of little computationally effort over existing source-localization methods. such as matched field processing or the waveguide invariant and array gain is fully exploited. And. no knowledge of the environment is required except that the received field should not be dominated by purely interference This simple and instantaneous method is applied to simulated acoustic propagation filed for testing range estimation performance. The result of range estimation according to the SNR for the underwater impulsive source with broadband spectrum is demonstrated. The spatial smoothing method is applied to suppress the effect of mutipath propagation by high frequency signal. The result of performance test for range estimation shows that the error rate is within 20% at the SNR above 10dB.

Digital Filter Model for Analog Helical Coil Spring Reverberator (헬리컬 코일 스프링 잔향기의 디지털 필터 모델)

  • Park Joon;Chon Sang-Bae;Lee Jong-Hoon;Sung Koeng-Mo;Song Sang-Seob
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.291-297
    • /
    • 2006
  • This paper proposes a new Digital Reverberator that models Analog Helical Coil Spring Reverberator for guitar amplifiers. While the conventional digital reverberators are proposed to provide better sound field mainly based on room acoustics, no algorithm or analysis of digital reverberators those model Helical Coil Spring Reverberator was proposed. Considering the fact that approximately $70{\sim}80$ percent of guitar amplifiers are still with Helical Coil Spring Reverberator, research was performed based not on Room Acoustics but on Helical Coil Spring Reverberator itself as an effector. After performing simulations with proposed algorithm, it was confirmed that the Digital Reverberator by proposed algorithm provides perceptually equivalent response to the conventional Analog Helical Coil Spring Reverberators.

A Study on Propeller Noise Localizations in a Cavitation Tunnel Using MFP (정합장 처리를 이용한 캐비테이션 터널에서의 프로펠러 소음원 위치 추적에 관한 연구)

  • Park, Cheol-Soo;Cho, Yong-Jin;Seol, Han-Shin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.5
    • /
    • pp.220-226
    • /
    • 2007
  • The two major objectives of acoustical measurements in a cavitation tunnel are measuring the noise levels generated by rotating propellers behind a hull and localizing possible noise sources in order to reduce noise levels. Propeller noise measurement experiments were performed in MOERI cavitation tunnel at December, 2006. In order to put the propeller into cavitating conditions, a wake-generating dummy body was devised. In addition, ten hydrophones are put inside a wing-shaped casing in order to minimize the unexpected flow induced self noise around hydrophone itself. After measuring both of the noises of the rotating propeller behind the dummy body and signals generated by a virtual source, respectively the data were matched field processed using the frequency incoherent Bartlett processor to localize noises on the propeller plane. In this paper, we presented the measured noise analysis and the localization results.

A Study on Development of Acoustic Tweezer System Using Standing Waves and Very High Frequency Focused Beams (정상파와 초고주파 집속 빔을 이용한 음향집게시스템의 개발에 관한 연구)

  • Yang, Jeong-Won;Ha, Kang-Lyeol;Kim, Moo-Joon;Lee, Jung-Woo;Shung, K.K.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.7
    • /
    • pp.357-364
    • /
    • 2008
  • For the purpose of possibility study on development of an acoustic tweezer using standing waves and very high frequency ultrasound focused beams, a system which can manipulate the position of particles in water has been constructed. It can move the particles to near focal point of a focused beam by the radiation force of standing waves, and then the particles would be trapped by the radiating force of the focused beam. The results show that micro sphere particles were trapped well at nodes of the standing waves and their position can be easily manipulated by frequency control. And, even though the radiation force by single focused beam pushes a particle away from the transducer, two focused confronted beams can trap it at near center.

Development of a Portable Hydrophone Array System (휴대용 수중청음기 배열 시스템의 개발)

  • Kim Bong-Chae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.178-183
    • /
    • 2006
  • A hydrophone away is used to measure spatial distribution in underwater sound field and to detect incoming direction of sound waves in the ocean. It is not usually convenient to handle the hydrophone away because of its extensive scale. And it is not easy to purchase the hydrophone away because of expensive price. A hydrophone logger combined with a hydrophone and data logger was developed to consist conveniently of a hydrophone away for use to receive underwater sound waves. And a hydrophone array system with the hydrophone loggers was developed. Main configurations of the hydrophone 1o99er and the hydrophone array system are introduced in this paper. Also we present some measurement results by the hydrophone logger in a water tank and measurement examples on ambient noise in the sea by the hydrophone away system. And we discuss some advantages in use of the hydrophone array system.

Thermoacoustic Power Generation by a Spiral Heater in the Rijke Tube (Rijke 관에서 나선형 가열기에 의한 열음향 파워의 생성)

  • Kwon, Young-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.491-496
    • /
    • 2010
  • Thermoacoustic power generation by a spiral heater in the Rijke tube was analyzed numerically. In the analysis, variables were normalized by the angular frequency of the sound and the thermal diffusivity of the air. The effect of the heater wire diameter d, the spacing between wires P-d, and the air-current velocity $U_0$, upon the power generation was obtained and discussed. When the spacing is broad enough, the normalized velocity is $U_0{\approx}0.8$ and the diameter is $d{\approx}4$ for the maximum power generation. With decrease of the spacing, however, the power generation increases more than 5 times and becomes maximum around $d{\approx}2$, $P-d{\approx}3$. And the velocity $U_0{\approx}0.8$ for the maximum power generation is almost independent of the wire spacing.

Effective Fan Noise Control Using Active Noise Control (능동소음제어를 이용한 효과적인 팬소음의 제어)

  • Eom Seung-Sin;Shin Inwhan;Lee Soogab
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.433-438
    • /
    • 1999
  • This paper describes Active Noise Cancellation/Control(ANC) method that removes the information of the unnecessary noise and doesn't remove the informations of the necessary noise(warning sound, operating sound etc.) for the induced noise of the mechanical system. In this paper, the noise source Is axial fan, and the Feedback Active Noise control method that can effectively control BPF generated from the axial fan is used, and the Filtered-X LMS algorithm for adaptive algorithms is used. The experiments are executed for two case(propagating noise in the duct, emission noise for exterior free field). The part to be removed is BPF noise, and the band-pass filter not to effect to the other frequencies is used. Also, to investigate the effect of the noise reduction for human, we are compared with the results that are controlled for using Loudness before and after. As a results, we are certified that the BPF is decreased only and frequencies outside of BPF are not affected, and we acquire the reduction effects of 6.7 dB Loudness Level, then the frequency to be removed is controlled. Therefore, we can be certified that sound pressure as well as loudness can be effectively decreased for human sound quality

  • PDF