• Title/Summary/Keyword: 유지력

Search Result 2,894, Processing Time 0.028 seconds

RETENTIVE FORCES OF CLASPS OF REMOVABLE ORTHODONTIC APPLIANCES FOR CHILDREN (어린이에게 사용되는 가철식 교정장치용 clasp의 유지력비교)

  • Han, Jeong-Jae;Lee, Kwang-Hee;Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.207-217
    • /
    • 1999
  • The purpose of this study was to compare the retentive forces of various types of clasps for removable orthodontic appliances for primary and mixed dentition. Seven metal models of a single tooth and two teeth were made, including maxillary left primary canine, first primary molar, second primary molar and first molar. Retentive forces of Adams clasp, circumferential clasp(C clasp), Jackson clasp, Duyzing clasp, arrowhead clasp, ball clasp, eyelet clasp, and triangular clasp were measured by Universal Testing Machine(Zwick Z020, Germany). The obtained results were as follows. 1. Jackson clasp and Adams clasp showed the highest retentive force among single tooth clasps. 2. C clasp showed the lowest retentive force, and there was no statistically significant difference in retentive force between mesial end C clasp and distal end C clasp. 3. Eyelet clasp showed the highest, and ball clasp showed the lowest retentive farce among clasps for interdental undercut. 4. Triangular clasp showed higher retentive force than ball clasp.

  • PDF

The Withdrawal Loads on The Effect of Dried Wooden Dowel (나무못 유지력에 나무못의 건조가 미치는 영향)

  • Cha, JaeKyung;Kim, Birm-June
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.613-621
    • /
    • 2017
  • This study was performed to determine the withdrawal loads and strengths on the effect of dried wooden dowel. The test block was manufactured from 15 mm thick domestic wood and particleboard. Dowels of 6, 8 and 10 mm in diameter are made of korean castanea, korean pine and tulip wood. Research reported here indicates that withdrawal loads increase, but withdrawal strengths decrease, as the dowel diameter increases. This study also indicates that withdrawal load and strength of dried wooden dowel showed over 10% increase compared to those of normal conditioned dowel. However, there was an exception for the case of korean pine test block with dried tulip wood dowel. Meanwhile, the dried wooden dowel withdrawal loads and strengths for particleboard test blocks show 6~14.4% and 6.2~18.2% increase, compared to those of normal conditioned dowel, respectively.

The Effect of Diameter and Prehole Clearance for Wooden Dowel on The Withdrawal Loads of Domestic Wood (국산재에 대한 나무못 직경과 천공 여척이 나무못 유지력에 미치는 영향)

  • Cha, Jae Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.736-742
    • /
    • 2016
  • Wooden dowels are commonly used to join the wooden members together in many types of structures, But little information is available concerning their holding properties in domestic wood. This study was performed to determine the withdrawal loads and strengths on the effect of diameter of dowel and hole clearance. The test block was manufactured from 15 mm thick korean red pine and korean pine. The dowel was manufactured 6, 8 and 10 mm diameters from korean castanea, korean pine and tuliptree. Research reported here indicates that withdrawal loads increase, but withdrawal strengths decrease, in a linear fashion as the dowel diameter increases. This study also indicates that dowel withholding load and strength increase in a linear fashion as a hole clearance decreases.

The Effects of Crosslinking Agent and pH Controlling Agent on Adhesive Properties of Water Soluble Acrylic PSA (가교제 및 pH 조절제가 수용성 아크릴 점착제의 점착 물성에 미치는 효과)

  • Seo, In-Seon;Park, Myung Chul;Lee, Myung Cheon
    • Journal of Adhesion and Interface
    • /
    • v.4 no.3
    • /
    • pp.9-13
    • /
    • 2003
  • In this paper, the effects of crosslinking agent and pH controlling agent on adhesive properties and water solubility of water soluble acrylic pressure sensitive adhesives were studied by adding the crosslinking agents or pH controlling agents after the polymerization. the tack, cohesive strength, and peel strength were measured to evaluate adhesive properties. the turbidity was also measured to evaluate water solubility of pressure sensitive adhesives. When crosslinking agent was added less than 0.2 wt%, tack increased and cohesive strength and peel strength decreased with increasing concentration. When crossinking agent was added more than 0.2 wt%, the results were opposited. When pH controlling agent was added, tack and water solubility decreased and peel strength and cohesive strength increased with increasing concentration. the influence of pH controlling agents on adhesive properties and water solubility of pressure sensitive adhesive increased in the order of lithium hydroxide, potassium hydroxide and sodium hydroxide.

  • PDF

A Study on the Retentive Force of Stud Attachments for Implant Overdenture (임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구)

  • Song, Eun-Ju;Bae, Eun-Bin;Choi, Jae-Won;Bae, Ji-Hyeon;Kim, Ji-Young;Lee, So-Hyoun
    • Journal of dental hygiene science
    • /
    • v.16 no.1
    • /
    • pp.93-100
    • /
    • 2016
  • The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.

The effect of denture adhesives on the retention of complete denture (의치 접착제가 총의치의 유지력에 미치는 영향에 관한 연구)

  • Yoon, Yu-Mi;Choi, Yu-Sung;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.87-93
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the retention of the two denture adhesives with a silicone edentulous model and a resin denture base in vitro study. Material and methods: The experimental groups were used two denture adhesives and classified into 5 subgroups each. Subgroups were divided by the number of times the saliva sprayed. The control group was used synthetic saliva only. Dislodging tensile strengths were applied to the resin denture base using Instron in 3 directions ; vertical, lateral, and anterior-posterior. Results: The retention of two denture adhesives was increased significantly than saliva alone (P <.05). In each denture adhesives, the retention of saliva sprayed first was decreased than denture adhesive alone, but it didn't have significant differences. Whenever saliva sprayed repeated, the retention was decreased significantly than saliva sprayed first (P <.05). In each denture adhesives, vertical retentive force was highest than lateral and anterior-posterior retentive forces, and anterior-posterior retentive force was higher than lateral retentive force. This results were significantly different (P < .05). Significant differences of the retentive ability among two denture adhesives were not observed. Conclusion: From the results, use of the denture adhesives resulted in improved retentive ability of denture. Especially retentive force was highest in vertical direction.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

A Study on the resistance of acrylic rubber pressure sensitive adhesives with curing agents and tackifiers (경화제와 점착부여제가 아크릴 고무점착제의 내열성에 미치는 영향)

  • Nam, Kyong min;Kim, Chul Yong;Kim, Eun Seon;Kim, Kwang-Je;Choi, Woo Jin;Kim, Ki-Tae;Park, Myung-Chul
    • Journal of Adhesion and Interface
    • /
    • v.18 no.4
    • /
    • pp.166-170
    • /
    • 2017
  • In this study, acrylic rubber pressure sensitive adhesives was polymerized with 2-ethylhexyl acrylate, styrene, butadiene, 2-hydroxyethyl acrylate, and acrylic acid by controlling the initiator content. The initial tackiness, peel strength, holding power, and heat resistance of the PSAs were investigated by changing the content of tackifier and curing agent. The results showed that the initial tackiness and peel strength increased as the content of tackifier increased, whereas the holding power decreased. Also, the results exhibited that that the initial tackiness, peel strength, and heat resistance decreased as the content of curing agent increased, whereas the holding power and decreased.

The Comparison of the Retention of the Full Veneer Casted Gold Crowns with Different Implant Abutment Shapes and Types of Cements (임플란트 지대주 형태와 시멘트 종류에 따른 전부주조금관의 유지력 비교)

  • Jung, Jae-Wook;Kim, Jee-hwan;Kim, Sun-jai;Moon, Hong-suk;Shim, June-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.403-415
    • /
    • 2009
  • The purpose of the study is to establish the effect of different abutment shapes and types of cements on the retention of the full veneer casted gold crowns. Metal dies that has the similar shape with the implant abutment were manufactured using a short(5mm) and long(10mm) dies with different convergence angles. Metal dies and gold crowns, which were made from the metal dies, were cemented with Temp-bond, Temp-bond mixed with petroleum jelly, ZPC and Premier implant cement. After that, these were tested for tensile force at the point of separation. The effect of convergence angle changes of different cement types on the retention was studied as well as the effects of the cement type changes with different convergence angles on the retention. In addition, study about the marginal gap of Premier implant cement used for this experiment was conducted. The results are as followed under the in-vitro experimental limits; 1. The retention of the Temp-bond mixed with petroleum jelly decreased as the convergence angle increased, and the retention was weakest among the cements. 2. The retention of ZPC decreased as convergence angle increased. When convergence angle was 5 degrees, ZPC showed stronger retention than Premier implant cement. 3. Premier implant cement had the weakest retention when the convergence angle was 5 degrees but when the convergence angle was 10 degrees, it had the strongest retention. As the angle increased more than 10 degrees, the retention decreased. 4. Premier implant cement showed bigger marginal gap when the convergence angle was 5 degrees than 10 degrees under the experimental condition.

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture