• Title/Summary/Keyword: 유입정

Search Result 612, Processing Time 0.032 seconds

Field Applicability Evaluation of Control Low Strength Materials as Utilizing Various Industrial by-Products (공동충전재로써 각종 산업부산물을 활용한 CLSM의 현장적용 가능성 평가)

  • Liao, Xiao-kai;Kim, Dong-Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.387-394
    • /
    • 2020
  • In this research, a physical property test of CLSM, which can safely and effectively utilize a great number of industrial byproducts and waste types, was used to review the applicability of GBFS, FNS, and FGB, as well as their field applicabilities as cavity fillers, and the following conclusions have been reached. first, For CLSM utilizing GBFS, FNS, and FGB, it was revealed that a proper mixing of over 30% of GBFS and FNS or within 5% of FGB is effective in improving the fluidity for field application. second, It was revealed that GF15B5 can suppress bleeding at a similar level as the base, whereas GF30B5 can do so at about 0.17% compared to the base. It was also verified that GF15, GF30, and GF45 can suppress bleeding at about 0.2%, 0.26%, and 0.3%, respectively, compared to the base. third, Both GF15B5 and GF30B5 exceeded 0.4MPa in 7day strength tests to satisfy the field application and, also, the rates of increase of their initial strengths were found to be 323% and 233% higher than the base, respectively. Meanwhile, the 7day strength test of GF, which utilizes GBFS and FNS, also reached over 0.2MPa for field application, and it was revealed that GF15, GF30, and GF45 show 160%, 237%, and 185% higher strength increase rates, respectively, compared to the base.

Comparisons of Foliar Nutrient Concentrations and Soil Nutrient Stocks Between Restoration Areas and Adjacent Red Pine Stands in Opencast Kaolinite Mines in Sancheong-gun (산청군 고령토 광산 복원지와 인접 소나무 임분의 토양양분 저장량 및 잎 양분 농도 비교)

  • Kim, Kyung Tae;Kim, Choonsig
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.2
    • /
    • pp.234-241
    • /
    • 2022
  • We performed this study to determine the foliar nutrient concentration and the nutrient stocks of restoration areas and adjacent Pinus densiflora S. et. Z. (red pine) stands in opencast kaolinite mines in Sancheong-gun, Gyeongsangnam-do, southern Korea. We chose six sites to determine foliage nutrient concentrations and the nutrient stocks of soils (0-10 cm depth). The dominant vegetation planted in restoration areas comprised Quercus acutissima Carruth., P. koraiensis S. et. Z., Festuca arundinacea Schreb., and Lespedeza cuneata G. Don. Invading vegetation in the restoration areas comprised Alnus incana (L.) Medik., Robinia pseudoacacia L., and Lespedeza spp., among others. The carbon and nitrogen stocks at 10 cm soil depth were significantly higher in the red pine stands than those in the restoration areas, whereas those of phosphorus, potassium, and magnesium were not significantly different between the two areas. However, calcium stocks were significantly higher in the restoration areas than in the red pine stands. Nitrogen concentration in foliage was higher in L. cuneata (20.28 mg N g-1) than that in F. arundinacea (5.67 mg N g-1), whereas potassium concentration was twice as high in F. arundinacea (18.8 mg K g-1) as that in L. cuneata (9.07 mg K g-1). Foliar nitrogen concentrations in invasive vegetation such as A. incana, R. pseudoacacia, and Lespedeza spp. were twice or four times higher than those of Q. acutissima and P. koraiensis. Our results indicate the development of suitable vegetation and soil amendment treatments to improve poor soil environmental conditions in restoration areas are necessary following opencast kaolinite mining.

Seasonal Change Analysis of Groundwater in Nakdong Riverside Greenhouse Complex Using Groundwater Monitoring (지하수관측을 이용한 낙동강변 시설농업단지 지하수의 계절적 변화 분석)

  • Baek, Mi Kyung;Shin, Hyun Chae;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.283-283
    • /
    • 2020
  • 국가의 논의 타작물 재배 권장 정책과 농한기 수익을 위해서 동절기에도 농사가 가능한 시설농업이 발달했으며, 1990년 초부터 재배면적이 증가하여 2000년에는 10만 ha를 넘어섰고, 2018년에는 80만ha의 규모를 보이고 있다(농사로, 2019). 시설농업단지의 동절기 난방을 위한 에너지원으로 화석연료와 전기열원을 사용하고 있고, 특히 강변의 경우 지하수를 난방 열원으로 사용가능해 수막재배를 이용한 대규모 시설단지가 발달함에 따라 지하수의 이용량이 증가하고, 2015년 농업용 지하수 이용량은 연간 20억 톤에 이른다(GIMS, 2019). 난방이 필요한 동절기에 수막용수를 위한 지하수 이용량이 급증하여 계절적인 수위변화를 보이며, 특히 강변의 대규모 시설농업단지의 지하수의 부족현상이 빈번히 발생하는 실정이다(송성호, 2017). 본 연구지역은 낙동강 하구댐 설치 전만조 시 해수의 유입으로 암반지하수의 심도가 증가할수록 EC가 증가하는 특성을 보이는 곳으로, 지하수의 이용량이 급증하는 동절기에 특히 급격히 증가하여 지하수의 안정적인 수질관리를 위해 염분변화의 관리가 필요한 지역이다. 지하수의 계절적인 변화를 위해 시설농업단지내에 지하수 관측정이 설치되어 관측되고 있으며 본 연구에서는 관측정의 2013년 1월~2019년 1월까지 지하수의 EC변화를 관측하였다. 지하수의 수위(GL.m), 온도, EC를 1시간 주기로 관측하여 계적적인 변화를 분석하였고, EC의 증가가 큰 곳은 심도별로 센서(다중심도)를 설치하여 염도의 변화를 관측하였다. 지하수성분의 지질학적 기원분석을 위한 양음이온 분석을 연 1회 실시하였다. 또한 관측정의 심도별 변화를 알기 위해 동일지역에 충적, 암반 관측정을 따로 설치하고 관측하여 지표수와 지하수의 심도별 영향의 차이를 분석하였다. 동일지역의 관측결과 평균 5m이하의 수위변화를 보이나, 5m 이상의 수위변동을 보이는 관측망은 15년 14개소 17년 19개소로 증가추세를 보이며, 이는 주로 밀집된 시설하우스 단지의 수막재배를 위한 겨울철 지하수 사용량 증가가 원인인 것으로 판단된다. 본 연구지역은 강변지역에 밀집된 시설하우스단지의 동절기 수막재배를 위한 지하수 과다 사용으로 수위급감 및 수량부족현상이 반복되고 있어, 예방과 대책강구를 위해 지표수의 함양과 지하수사용량의 상관관계 분석과 자료축적 및 추가연구를 위한 장기관측이 요구된다.

  • PDF

Removal Characteristics of Residual Hydrogen Peroxide (H2O2) according to Application of Peroxone Process in O3/BAC Process (O3/BAC 공정에서 Peroxone 공정 적용에 따른 잔류 과산화수소 제거 특성)

  • Yeom, Hoon-Sik;Son, Hee-Jong;Seo, Chang-Dong;Kim, Sang-Goo;Ryu, Dong-Choon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.889-896
    • /
    • 2013
  • Advanced Oxidation Processes (AOP) have been interested for removing micropollutants in water. Most of water treatment plants (WTPs) located along the lower part of Nakdong River have adopted the $O_3/BAC$ process and have interesting in peroxone process a kind of AOP. This study evaluated the removal characteristics of residual hydrogen peroxide ($H_2O_2$) combining with the biofiltration process in the next BAC process when the hydrogen peroxide is applied for the WTP operating $O_3/BAC$ process. In the experiment, changing the temperature and the concentration of $H_2O_2$ of influent, the biofiltration process showed rapidly dropped the biodegradability when the $H_2O_2$ concentration was increased and lowered water temperature while BAC process maintained relatively stable efficiency. The influent fixed at $20^{\circ}C$ and the concentration of $H_2O_2$ at 300 mg/L was continuously input for 78 hours. Most of the $H_2O_2$ in the influent did not remove at the biofiltration process controlled 5 to 15 minutes EBCT condition after 24~71 hours operating time while BAC process controlled 5 to 15 minutes EBCT showed 38~91% removal efficiency condition after 78 hours operating time. Besides, after 78 hours continuously input experiment, the biomass and activity of attached bacterial on the biofilter and BAC were $6.0{\times}10^4CFU/g$, $0.54mg{\cdot}C/m^3{\cdot}hr$ and $0.4{\times}10^8CFU/g$, $1.42mg{\cdot}C/m^3{\cdot}hr$ respectively. These biomass and activity values were decreased 99% and 72% in biofilter and 68% and 53% in BAC compared with initial condition. The biodegradation rate constant ($k_{bio}$) and half-life ($t_{1/2}$) in BAC were decreased from $1.173min^{-1}$ to $0.183min^{-1}$ and 0.591 min to 3.787 min respectively according to increasing the $H_2O_2$ concentration from 10 mg/L to 300 mg/L at $5^{\circ}C$ water temperature and the $k_{bio}$ and $t_{1/2}$ were $1.510min^{-1}$ to $0.498min^{-1}$ and 0.459 min to 1.392 min at $25^{\circ}C$ water temperature. By increasing the water temperature from $5^{\circ}C$ to $15^{\circ}C$ or $25^{\circ}C$, the $k_{bio}$ were increased 1.1~2.1 times and 1.3~4.4 times. If a water treatment plant operating $O_3/BAC$ process is considering the hydrogen peroxide for the peroxone process, post BAC could effectively decrease the residual $H_2O_2$, moreover, in case of spilling the $H_2O_2$ into the water process line, these spilled $H_2O_2$ concentration can be able to decrease by increasing the EBCT at the BAC process.

A Study on the Seawater Filtration Characteristics of Single and Dual-filter Layer Well by Field Test (현장실증시험에 의한 단일 및 이중필터층 우물의 해수 여과 특성 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.51-68
    • /
    • 2019
  • This study performs to evaluate adaptability of seashore filtering type seawater-intake which adapts dua1 filter well alternative for direct seawater-intake. This study varies filter condition of seashore free surface aquifer which is composed of sand layer then installs real size dual filter well and single filter well to evaluate water permeability and proper pumping amount according to filter condition. According to result of step aquifer test, it is analysed that 110.3% synergy effect of water permeability coefficient is happened compare to single filter since dual filter well has better improvement. dual filter has higher water permeability coefficient compare to same pumping amount, this means dual filter has more improved water permeability than single filter. According to analysis result of continuous aquifer test, it is evaluated that dual filter well (SD1200) has higher water permeability than single filter well (SS800) by analysis of water permeability coefficient using monitoring well and gauging well, it is also analysed dual filter has 110.7% synergy effect of water permeability coefficient. As a evaluation result of pumping amount according to analysis of water level dropping rate, it is analysed that dual filter well increased 122.8% pumping amount compare to single filter well when water level dropping is 2.0 m. As a result of calculating proper pumping amount using water level dropping rate, it is analysed that dual filter well shows 136.0% higher pumping amount compare to single filter well. It is evaluated that proper pumping amount has 122.8~160% improvement compare to single filter, pumping amount improvement rate is 139.6% compare to averaged single filter. In other words, about 40% water intake efficiency can be improved by just installation of dual filter compare to normal well. Proper pumping amount of dual filter well using inflection point is 2843.3 L/min and it is evaluated that daily seawater intake amount is about $4,100m^3/day$ (${\fallingdotseq}4094.3m^3/day$) in one hole of dual filter well. Since it is possible to intake plenty of water in one hole, higher adaptability is anticipated. In case of intaking seawater using dual filter well, no worries regarding damages on facilities caused by natural disaster such as severe weather or typhoon, improvement of pollution is anticipated due to seashore sand layer acts like filter. Therefore, It can be alternative of environmental issue for existing seawater intake technique, can save maintenance expenses related to installation fee or damages and has excellent adaptability in economic aspect. The result of this study will be utilized as a basic data of site demonstration test for adaptation of riverside filtered water of upcoming dual filter well and this study is also anticipated to present standard of well design and construction related to riverside filter and seashore filter technique.

Remediation for Gasoline Contaminated Soils with SVE (soil vapor extraction) Including a Post-treatment System of Extraction Gases (배출가스의 후처리 공정을 포함한 토양증기추출법을 이용한 가솔린 오염 토양 복원)

  • 이민희;강현민;이병헌;빈정인
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.2
    • /
    • pp.28-40
    • /
    • 2004
  • Box experiments were performed to evaluate the removal efficiency of SVE (soil vapor extraction) for gasoline in soil. An activated carbon sorption tower and a biofilter were operated as post-treatment processes to remove VOCs extracted from extraction wells of SVE. An acrylic resin box (65 cm${\times}$20 cm${\times}$30 cm) was used to make artificial soil layers and two injection wells and one extraction well were built for SVE process in the box. Gases from extraction wells flew into the activated carbon sorption tower or the biofilter. Gasoline concentrations of VOCs emitted from the extraction well were compared with those after post treatments. More than 92% of initial gasoline mass in soil were removed by SVE within few days, suggesting that SVE is very available to remove VOCs from contaminated soils. To treat VOCs from extraction wells of SVE, an activated carbon sorption tower and a biofilter were attached to SVE process and their gasoline removal efficiencies were measured. These post treatment systems lowered gasoline concentrations to below 1.0 ppm within few days. Average remediation efficiency was 98% of gasoline for the activated carbon sorption tower and 84.1% for the biofilter. The maximum removal capacity of a biofilter was 10.7 g/L/hr, which was ten times higher than general biofilter removal capacity. Results from the study suggest that the activated carbon sorption tower and the biofilter would be available for the post treatment process to remove VOCs generated from SVE process.

The Study on the Relationship between Land Use and Groundwater Quality in the Rapidly Urbanized Area (도시화가 빠르게 진행된 지역의 토지이용과 지하수 수질과의 관계에 대한 연구)

  • An, Jung-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.1
    • /
    • pp.97-108
    • /
    • 2002
  • The use of land at the time of investigation of groundwater quality in the rapidly urbanized Bu-chon city is classified into 5 categories based on the change process of land use. The difference in groundwater quality according to the land use and its usage period is tested by non-parametric statistical procedures. The seven constituents of water quality with the highly frequent detection in the area for this study are used for the statistical test. The shallow groundwater quality within the areas of the same land use at the time of investigation varies significantly according to the period of land usage. The concentration of KMnO$_4$consumed and hardness is significantly higher in the old residential area (of more than 20 years old) than in the younger one (of less than 10 years old). The quality of the shallow groundwater is also significantly different among the three categories with the similar period of land usage (of more than 15 years old). The concentration of No$_3$-N, hardness and total solid is significantly higher in the residential area than in the agricultural one (namely, the area used as paddy fields 2 to 5 years ago). The median concentration of these constituents is 2.2 to 3.8 times higher in the residential area than in the agricultural one. The concentration of NO$_3$-N, KMnO$_4$, consumed and Cl is significantly higher in the industrial area than in the agricultural one. The median concentration of these constituents is 5.5 to 18 times higher in the industrial area than in the agricultural one. The concentration of KMnO$_4$consumed is significantly higher in the industrial area than in the residential area. The median concentration of these constituents is 12 times higher in the industrial area than in the residential one. The spatial distribution of shallow groundwater quality in the rapidly urbanized area is closely related to the period of land usage as well as the land use, which is presumed to be attributed to the difference in the concentration and leakage rate of the contaminants leaking from damaged sewer into shallow groundwater.

Relationship Between Standardized Precipitation Index and Groundwater Levels: A Proposal for Establishment of Drought Index Wells (표준강수지수와 지하수위의 상관성 평가 및 가뭄관측정 설치 방안 고찰)

  • Kim Gyoo-Bum;Yun Han-Heum;Kim Dae-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.3
    • /
    • pp.31-42
    • /
    • 2006
  • Drought indices, such as PDSI (palmer Drought Severity Index), SWSI (Surface Water Supply Index) and SPI (Standardized Precipitation Index), have been developed to assess and forecast an intensity of drought. To find the applicability of groundwater level data to a drought assessment, a correlation analysis between SPI and groundwater levels was conducted for each time series at a drought season in 2001. The comparative results between SPI and groundwater levels of shallow wells of three national groundwater monitoring stations, Chungju Gageum, Yangpyung Gaegun, and Yeongju Munjeong, show that these two factors are highly correlated. In case of SPI with a duration of 1 month, cross-correlation coefficients between two factors are 0.843 at Chungju Gageum, 0.825 at Yangpyung Gaegun, and 0.737 at Yeongju Munjeong. The time lag between peak values of two factors is nearly zero in case of SPI with a duration of 1 month, which means that groundwater level fluctuation is similar to SPI values. Moreover, in case of SPI with a duration of 3 month, it is found that groundwater level can be a leading indicator to predict the SPI values I week later. Some of the national groundwater monitoring stations can be designated as DIW (Drought Index Well) based on the detailed survey of site characteristics and also new DIWs need to be drilled to assess and forecast the drought in this country.

A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks (저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구)

  • Noh, Yoorae;Kim, Sang-Hyo;Choi, Sung-Uk;Park, Joonhong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.63-75
    • /
    • 2016
  • For safe water supply, residual chlorine has to be maintained in tap-water above a certain level from drinking water treatment plants to the final tap-water end-point. However, according to the current literature, approximately 30-60% of residual chlorine is being lost during the whole water supply pathways. The losses of residual chlorine may have been attributed to the current tendency for water supply managers to reduce chlorine dosage in drinking water treatment plants, aqueous phase decomposition of residual chlorine in supply pipes, accelerated chlorine decomposition at a high temperature during summer, leakage or losses of residual chlorine from old water supply pipes, and disappearances of residual chlorine in water storage tanks. Because of these, it is difficult to rule out the possibility that residual chlorine concentrations become lower than a regulatory level. In addition, it is concerned that the regulatory satisfaction of residual chlorine in water storage tanks can not always be guaranteed by using the current design method in which only storage capacity and/or hydraulic retention time are simply used as design factors, without considering other physico-chemical processes involved in chlorine disappearances in water storage tank. To circumvent the limitations of the current design method, mathematical models for aqueous chlorine decomposition, sorption of chlorine into wall surface, and mass-transfer into air-phase via evaporation were selected from literature, and residual chlorine reduction behavior in water storage tanks was numerically simulated. The model simulation revealed that the major factors influencing residual chlorine disappearances in water storage tanks are the water quality (organic pollutant concentration) of tap-water entering into a storage tank, the hydraulic dispersion developed by inflow of tap-water into a water storage tank, and sorption capacity onto the wall of a water storage tank. The findings from his work provide useful information in developing novel design and technology for minimizing residual chlorine disappearances in water storage tanks.

Planktic Foraminiferal Assemblages of Core Sediments from the Korea Strait and Paleoceanographic Changes (대한해협 코아 퇴적물의 부유성 유공충 군집 특성과 고해양 환경 변화)

  • Kang, So-Ra;Lim, D.I.;Rho, K.C.;Jung, H.S.;Choi, J.Y.;Yoo, H.S.
    • Journal of the Korean earth science society
    • /
    • v.27 no.4
    • /
    • pp.464-474
    • /
    • 2006
  • The paleoceanography since 14 ka was reconstructed based on the planktic foraminiferal assemblages of core sediments from the outer shelf of the Korea Strait. Planktic foraminifera in the core sediments can be divided into four assemblages: A, B, C, and D. Assemblage A consists mainly of Globigerinoides ruber group and Globigerinoides conglobatus with low abundance (less than 10%), indicating the tropical-subtropical water mass. Assemblage B is composed of Pulleniatina obliquiloculata and Neogloboquadrina dutertrei, the indicator of Kuroshio Current, and shows the aspect of the inflow of the Tsushima Current into the Korea Strait. Assemblage C yields polar-subpolar species, mainly Neogloboquadrina incompta and N. pachyderma. It decreases upward of the core. Assemblage D contains coastal water species such as Globigerina bulloides and G. quinqueloba. It is abundant in the lower to middle region of the core. From the analysis of distributions of each assemblage and the result of age datings in the core, it is suggested that the Korea Strait played a role of channelling the East China Sea and the East Sea after the LGM (ca. 14 ka). During this time, the coastal water, affected by fresh waters originated from the river systems of China and/ or the Korean Peninsula, flourished around the Korea Strait and theses coastal water might entered to the East Sea. Around 8.5 ka, the effect of the Tsushima Current started to strengthen in this region, and the present current system seems to be formed at about $7{\sim}6ka$.