Removal Characteristics of Residual Hydrogen Peroxide (H2O2) according to Application of Peroxone Process in O3/BAC Process  

Yeom, Hoon-Sik (Water Quality Institute, Busan Water Authority)
Son, Hee-Jong (Water Quality Institute, Busan Water Authority)
Seo, Chang-Dong (Water Quality Institute, Busan Water Authority)
Kim, Sang-Goo (Water Quality Institute, Busan Water Authority)
Ryu, Dong-Choon (Water Quality Institute, Busan Water Authority)
Publication Information
Abstract
Advanced Oxidation Processes (AOP) have been interested for removing micropollutants in water. Most of water treatment plants (WTPs) located along the lower part of Nakdong River have adopted the $O_3/BAC$ process and have interesting in peroxone process a kind of AOP. This study evaluated the removal characteristics of residual hydrogen peroxide ($H_2O_2$) combining with the biofiltration process in the next BAC process when the hydrogen peroxide is applied for the WTP operating $O_3/BAC$ process. In the experiment, changing the temperature and the concentration of $H_2O_2$ of influent, the biofiltration process showed rapidly dropped the biodegradability when the $H_2O_2$ concentration was increased and lowered water temperature while BAC process maintained relatively stable efficiency. The influent fixed at $20^{\circ}C$ and the concentration of $H_2O_2$ at 300 mg/L was continuously input for 78 hours. Most of the $H_2O_2$ in the influent did not remove at the biofiltration process controlled 5 to 15 minutes EBCT condition after 24~71 hours operating time while BAC process controlled 5 to 15 minutes EBCT showed 38~91% removal efficiency condition after 78 hours operating time. Besides, after 78 hours continuously input experiment, the biomass and activity of attached bacterial on the biofilter and BAC were $6.0{\times}10^4CFU/g$, $0.54mg{\cdot}C/m^3{\cdot}hr$ and $0.4{\times}10^8CFU/g$, $1.42mg{\cdot}C/m^3{\cdot}hr$ respectively. These biomass and activity values were decreased 99% and 72% in biofilter and 68% and 53% in BAC compared with initial condition. The biodegradation rate constant ($k_{bio}$) and half-life ($t_{1/2}$) in BAC were decreased from $1.173min^{-1}$ to $0.183min^{-1}$ and 0.591 min to 3.787 min respectively according to increasing the $H_2O_2$ concentration from 10 mg/L to 300 mg/L at $5^{\circ}C$ water temperature and the $k_{bio}$ and $t_{1/2}$ were $1.510min^{-1}$ to $0.498min^{-1}$ and 0.459 min to 1.392 min at $25^{\circ}C$ water temperature. By increasing the water temperature from $5^{\circ}C$ to $15^{\circ}C$ or $25^{\circ}C$, the $k_{bio}$ were increased 1.1~2.1 times and 1.3~4.4 times. If a water treatment plant operating $O_3/BAC$ process is considering the hydrogen peroxide for the peroxone process, post BAC could effectively decrease the residual $H_2O_2$, moreover, in case of spilling the $H_2O_2$ into the water process line, these spilled $H_2O_2$ concentration can be able to decrease by increasing the EBCT at the BAC process.
Keywords
Peroxone Process; Ozone/BAC Process; Residual Hydrogen Peroxide; Attached Bacteria; Biodegradation;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Seo, I. S., Son, H. J., Choi, Y. I., Ahn, W. S. and Park, C. G., "Removal characteristics of nitrogeneous organic chlorination disinfection by-products by activated carbon and biofiltration," J. Kor. Soc. Environ. Eng., 29(2), 184-191(2007).
2 Ibrahim, M. and Schlegel, H. G., "Oxygen supply to bacterial suspensions of high cell densities by hydrogen peroxide," Biotechnol. Bioengr., 22(9), 1877-1894(1980).   DOI   ScienceOn
3 Bandala, E. R., Pelaez, M. A., Garcia-Lopez, J., Salgado, M. J. and Moeller, G., "Photocatalytic decolourisation of synthetic and real textile wastewater containing benzidine-based azo dyes," Chem. Eng. Proc., 47, 169-176(2008).   DOI   ScienceOn
4 Nakayama, S., Esaki, K., Namba, K., Taniguchi, N. and Tabata, N., "Improved ozonation in aqueous systems," Ozone Sci. Eng., 1(2), 119-131(1979).   DOI   ScienceOn
5 Esplugas, S., Bila, D. M., Krause, L. G. T. and Dezotti, M., "Ozonation and advanced oxidation technologies to remove endocrine disrupting chemicals (EDCs) and pharmaceuticals and personal care products (PPCPs) in water effluents," J. Hazard. Mater., 149, 631-642(2007).   DOI   ScienceOn
6 Klavarioti, M., Mantzavinos, D. and Kassinos, D., "Removal of residual pharmaceuticals from aqueous system by advanced oxidation processes," Environ. Int., 35, 402-417(2009).   DOI   ScienceOn
7 Son, H. J., Kim, S. G., Yeom, H. S. and Choi, J. T., "Evaluation of applicability and economical efficiency of peroxone process for removal of micropollutants in drinking water treatment," J. Kor. Environ. Sci. Intl., 22(7), 905-913(2013).   과학기술학회마을   DOI   ScienceOn
8 Brunet, R., Bourbigot, M. M. and Dore, M., "Oxidation of organic compounds through the combination ozone-hydrogen peroxide, Ozone Sci. Eng., 6(3), 163-183(1984).   DOI   ScienceOn
9 Duguet, J. P., Brodard, E., Dussert, B. and Mallevialle, J., "Improvement in the effectiveness of ozonation of drinking water through the use of hydrogen peroxide," Ozone Sci. Eng., 7, 241-258(1985).   DOI   ScienceOn
10 Glaze, W. H., Kang, J. W. and Chapin, D. H., "The chemistry of water treatment processes involving ozone. hydrogen peroxide and ultraviolet radiation," Ozone Sci. Eng., 9(4), 335-352(1987).   DOI
11 Roche, P., Volk, C., Carbonnier, F. and Paillard, H., "Water oxidation by ozone/hydrogen peroxide using the 'Ozotest' or 'Peroxotest' methods," Ozone Sci. Eng., 16(2) 135-155(1994).   DOI
12 Bader, H., Sturzenegger, V. and Hoigne, J., "Photometric method for the determination of low concentrations of hydrogen peroxide by the peroxidase catalyzed oxidation of N,Ndiethyl-p-phenyl-enediamine (DPD)," Water Res., 22(9), 1109-1115(1988).   DOI   ScienceOn
13 Lin, A. Y. C., Yu, T. H. and Lin, C. F., "Pharmaceutical contamination in residual, industrial, and agricultural waste streams: risk to aqueous environments in Taiwan," Chemosphere, 74, 131-141(2008).   DOI   ScienceOn
14 Son, H. J., Choi, Y. I., Bae, S. D. and Jung, C. W., "Removal of 1,4-dioxane in ozone and activated carbon process," J. Kor. Soc. Environ. Eng., 28(12), 1280-1286(2006).   과학기술학회마을
15 Ferguson, D. W., McGuire, M. J., Koch, B., Wolfe, R. L. and Aieta, E. M., "Comparing peroxone and ozone for controlling taste and odor compounds, disinfection by-products, and microorganisms," J. AWWA, 82(4), 181-191(1990).
16 Fuhrman, J. A. and Azam, F., "Thymidine incorporation as a measure of heterotrophic bacterio-plankton production in marine surface waters: evaluation and field results," Mar. Biol., 66, 109-120(1982).   DOI
17 Son, H. J., Jung, C. W. and Kim, S. H., "Removal of bisphenol- A using rotating photocatalytic oxidation drum reactor (RPODR)," Environ. Eng. Res., 13(4), 197-202(2008).   과학기술학회마을   DOI   ScienceOn
18 Son, H. J., Park, H. K., Lee, S. A., Jung, E. Y. and Jung, C. W., "The characteristics of microbial community for biological activated carbon in water treatment plant," J. Kor. Soc. Environ. Eng., 27(12), 1311-1320(2005).   과학기술학회마을
19 Marhaba, T. F. and Bengraine, K., "Review of strategies for minimizing bromate formation resulting from drinking water ozonation," Clean Technol. Environ. Policy, 5, 101-112(2003).   DOI   ScienceOn
20 Son, H. J., Yeom, H. S. and Bin, J. H., "Peroxone ($O_3/H_2O_2$) process in drinking water treatment," J. Kor. Soc. Environ. Eng., 32(3), 296-308(2010).   과학기술학회마을
21 APHA, AWWA, WEF, "Heterotrophic plate count," Standard Methods for the Examination of Water and Wastewater, Eaton, A. D., Clesceri, L. S. and Greenberg, A. E. (Eds), APHA, AWWA, WEF, Washington DC, 19th ED, pp. 9-31-9-35(1995).
22 Parsons, T. R., Maita, Y. and Lalli, C. M., A Manual of Chemical and Biological Methods for Seawater Analysis, Pergamon, New York(1984).
23 Bell, R. T., Ahlgren, G. M. and Ahlgren, I., "Estimating bacterioplankton production by the [$^3H$]thymidine incorporation in a eutrophic Swedish Lake," Appl. Environ. Microbiol., 45, 1709-1721(1983).
24 Baldry, M. G. C., "The bactericidal, fungicidal and sporicidal properties of hydrogen peroxide and peracetic acid," J. Appl. Bacteriol., 54(3), 417-423(1983).   DOI
25 Bae, S. D., Son, H. J. and Jung, C. W., "Removal characteristics of chloral hydrate by activated carbon and biofiltration," J. Kor. Soc. Environ. Eng., 30(2), 218-224(2008).