• Title/Summary/Keyword: 유온

Search Result 14, Processing Time 0.025 seconds

A Study on the Refining Performance Improvement of Marine Sludge Fuel Oil(I) (for the temperature and pressure effects in metal filtering element) (선박 슬러지유의 정유성능 향상에 관한 연구(I)(금속여과망의 유압력 및 유온의 영향에 대해서))

  • 한원희;하만식;이진열
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.9 no.1
    • /
    • pp.89-94
    • /
    • 2003
  • As ship's fuel oil recently becomes viscous and the amount of sludge increases, many researches and studies are underway to process the sludge onboard the ship and to recycle it as a fuel for ship's boiler. Of many researches, especially ultrasonic emulsifier to break the particle of sludge into fine pieces is recognized as a most possible recycling device. In this regards, the author investigates the property change of sludge's temperature and pressure at the early stage of the study of ultrasonic emulsifier. This study can be used as a useful dora to determine the proper temperature and pressure to inject the processed sludge in the boiler injector and the results can also be comparable dora with the experimental data by ultrasonic emulsifier. In addition, the results will be a fundamental data to study the filtering efficiency of the sludge particle broken by temperature and pressure. It is expected that this study ultimately play a role to prevent marine oil pollution as the sludge is recycled onboard the ship and used as a fuel for boiler.

  • PDF

Transformer Temperature forecast method using Top Oil Temperature Rising & Current (최상부 유온 상승과 전류를 이용한 변압기 온도 예측 방법)

  • Ko, Dong-Wook;Kim, Kwang-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1689-1690
    • /
    • 2008
  • In this paper, The method of a temperature rasing forecast is suggested and simulated. The data used in this simulations exists in the KD Power and it was obtain by real transformer. The method of temperature forecast is based on a top oil temperature rising modeling which is proposed by the IEEE journal. We propose modifications of a modeling that accurately predicts a future transformer temperature. This Method is verified by simulations.

  • PDF

A study on the effect of surfactants on the streaming electrification of insulating oil (절연유의 유동대전에 미치는 계면활성제의 영향에 관한 연구)

  • 임헌찬;박재윤;김진식;김진식;이덕출
    • Electrical & Electronic Materials
    • /
    • v.5 no.1
    • /
    • pp.81-88
    • /
    • 1992
  • 본 연구는 고체-액체 계면에서 액체가 유동할때 발생되는 대전에 미치는 계면 활성제의 영향에 대하여 분석한 것이다. 유동전류는 유속의 증가에 따라 선형적으로 증가하고 유온의 증가에 따라 약 46[.deg.C] 이하에서는 증가하고 그 이상에서는 감소한다. 계면활성제의 종도가 증가함에 따라 유동전류는 감소하고 계면활성제의 한 분자내 산소 원자의 수가 많을수록 유동전류의 감소효과가 크게 됨을 제시할 수 있다. 계면활성제가 첨가된 절연유의 전도전류는 온도에 따라 무첨가보다 다소 큰 경향이 있으나 첨가량에는 현저한 차이가 없다.

  • PDF

Overload Criterion of Mineral-Oil-immersed Distribution Transformers Rated 100kVA and Less Using the Characteristics of Top-Oil Temperature Rising (최상부 유온 상승 특성을 이용한 100kVA 이하 유입식 배전용 변압기의 과부하 판정 기준)

  • Yun, Sang-Yun;Kim, Jae-Chul;Park, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.11
    • /
    • pp.559-567
    • /
    • 2002
  • This paper presents the general recommendations for the overload criterions of mineral-oil-immersed distribution transformers rated 100kVA and less. For this purpose, we analyze the characteristics of top-oil temperature rising for mineral-oil-immersed power distribution transformer rated 100kVA and less, manufactured in Korea, In order to analyze the characteristics of top-oil temperature rising due to the distribution transformer loading, we performed experiments at KERI (Korea Electrical Research Institute) from December 2000 to May 2001. The restraint of ambient temperatures for the experiment results is solved using the results of foreign standards. Finally, we present the overload criterions of distribution transformer for summer and winter season, respectively.

A Diagnostic Technique for Distribution Transformers using Top Oil Temperature (최상부 유온을 이용한 배전용 변압기의 진단 기법)

  • Choe, Do-Hyeok;Yun, Yong-Han;Min, Gyeong-Rae;Kim, Jae-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.5
    • /
    • pp.242-251
    • /
    • 2000
  • In this paper, we argued the possibility of the diagnostic technique for distribution transformers using the top oil temperature rising above the ambient temperature. The proposed diagnostic technique used the reference top oil temperature rising at rated current. We determined the emergency value of the transformer using the limitation of the top oil temperature rising and calculated the loss of life. The top oil temperature rises because of the load currents. In this point, the proposed diagnostic technique was explained. The proposed system measures the load current, top oil temperature and ambient temperature. With the diagnostic device, we tested the top oil temperature rising of t재 transformers. Then the loss of life was calculated by the top oil temperature.

  • PDF

Characteristics Experiment of Domestic Developed Hydraulic Axial Piston Motor (개발한 국산화 유압 액셜피스톤모터의 특성실험)

  • Yum, Man-Oh;Lee, Sang-Yun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.70-76
    • /
    • 2007
  • The purpose of this study is to analyze the characteristics of a domestic developed hydraulic axial piston motor. An experimental apparatus was constructed and the output torque, the input oil pressure, the input flow rate, the speed of motor and oil temperature were measured. They were measured under both no load and load conditions. The results are as follows; 1. Motion of motor became steady state conditions after 5 seconds. 2. Output torque of motor was proportional to input oil pressure under both load and unload. 3. Speed of motor decreased with increasing load. 4. Oil temperature was almost constant. The results of this study will offer the basic data in designing and operating hydraulic axial piston motors.

The Influence of Velocity and Temperature on Streaming Charging Tendeny of Insulting Oil (절연유의 유속과 유온이 유동대전에 미치는 영향)

  • Kim, Myung-Nyung;Kang, Seong-Hwa;Lim, Kee-Joe;Kang, Dou-Yol;Kim, Bong-Heup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.70-73
    • /
    • 1988
  • Influence of Velocity and Temperature on Streaming Electrification of Insulating Oil is investigated by injection method. Leakage current is increased slightly with increasing temperature in the temperature range 20 to $80^{\circ}C$ at low flow rate, however, it show a peak in the temperature 40 to $60^{\circ}C$ at high flow rate. Leakage current is also increased linearly with increasing flow rate in the flow rate range 1 - 31/min but thereafter, it is increased abruptly with increasing flow rate.

  • PDF

A study on the effect of solid materials on the streaming electrification of insulating oil (절연유의 유동대전에 미치는 고체재질의 영향에 관한 연구)

  • 김용운;임헌찬;김영일;김영봉;이덕출
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.236-242
    • /
    • 1994
  • In this paper, the streaming electrification characteristics of insulating oil were examined when the oil is contacted with solid materials in a circulating system. The streaming current($I_s$) increases with increasing oil velocity and temperature, and electrification properties depend on species of metal materials. $I_s$ in the gauze-contained electrification apparatus increases with increasing oil temperature below the temperature of 43[>$^{\circ}C$], but decreases above 43[>$^{\circ}C$]. On the other hand, $I_s$ is positive electrificated for the pipe of Fe, Cu, while it is negative electrificated for Sus. When insulating oil flows through a car fuel filter, $I_s$ increases linearly with increasing oil temperature.

  • PDF

Analysis of Surplus Flow in a Hydraulic System Applied to a Self-propelled Spinach Harvester (자주식 시금치 수확장치에 적용된 유압시스템의 잉여유량 분석)

  • Noh, Dae Kyung;Lee, Dong Won;Lee, Jong Su;Jang, Joo Sup
    • Journal of Drive and Control
    • /
    • v.19 no.1
    • /
    • pp.26-33
    • /
    • 2022
  • This study dealt with a self-propelled spinach harvester, which is capable of carrying out sequential harvesting work. This study aimed to find the cause of the harvester's occasional performance deterioration, which occurs in the process of simplifying the hydraulic circuit, using a multi-domain analysis model. The study was carried out in the following manner. First, a hydraulic system analysis model, which combines linear motion, rotary motion, hydrodynamic behavior, and an electrical signal, was developed through SimulationX software, specialized in multi-domain analysis. Second, a scenario for single behavior and coupled behavior was set out on an actuator basis. Third, the flow rate of the hydraulic system, which is not required for the movement of the actuator, was quantitatively analyzed. The results showed that a change in oil temperature was the cause of the harvester's occasional performance deterioration. And the higher the oil temperature, the more serious the performance deterioration, especially as the number of actuators operated simultaneously was small.

An Experimental Study on the Thermal Characteristics of Direct Contact Liquid-Ice Heat Exchanger (직접접촉식 액-빙 열교환기의 전열특성에 관한 실험적 연구)

  • Lee, Chae-Moon;Park, Jung-Won;Kim, Dong-Hun
    • Solar Energy
    • /
    • v.16 no.2
    • /
    • pp.65-77
    • /
    • 1996
  • The operating thermal chracteristics of direct contact liquid-ice heat exchanger was experimentally investigated. In this paper, The effects of Ice Packing Factor(IPF), the inlet temperature and the flow rate of Heat Transfer Fluid(HTF) were stuided in the liquid-ice heat exchanger. Thermal stratification in liquid-ice heat exchanger was established clearly and faster at the higher inlet temperature and flow rate of HTF. At the end of melting of the lower flow rate is cleared the thermal stratification in liquid-ice heat exchanger. The temperature stratification is long with higher value of IPF of liquid-ice heat exchanger. The mean temperature of liquid-ice storage was changed rapidly with increasing flow rate and inlet temperature of HTF. The gradiant of ratio of total energy to latent energy was found higher with increasing inlet temperature and flow rate.

  • PDF