Active Lamb Wave Propagation-based Structural Health Monitoring for Steel Plate (능동 램파 전파에 기초한 강판의 구조건전성 모니터링)

  • Jeong, Woon;Seo, Ju-Won;Kim, Hyeung-Yun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.421-431
    • /
    • 2009
  • This paper is the study on the verification of structural health monitoring (SHM) algorithm based on the ultrasonic guided wave. An active inspection system using Lamb wave (LW) for SHM was considered. The basic study about the application of this algorithm was performed for detecting the circular notch defect in steel plate. LW testing technique, pitch-catch method, was used for interpretation of circular notch defect with depth of 50% of plate thickness and 7 mm width. Damage characterization takes place by comparing $S_0$ mode sensor signals collected before and after the damage event. By subtracting the signals of both conditions from each other, a scatter signal is produced which can be used for damage localization. The continuous Gabor wavelet transform is used to attain the time between the arrivals of the scatter and sensor signals. A new practical damage monitoring algorithm, based on damage monitoring polygon and pitch-catch method, has been proposed and verified with good accuracy. The possible damage location can be estimated by the average on calculated location points and the damage extent by the standard deviation.

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer (자궁경부암 환자의 근접치료시 재현성 평가)

  • Kim Jong-Hwa;Son Jung-Hae;Jung Chil;Kim Mi-Hwa
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • I. Purpose Brachytherapy is the main component in treatment of patients with uterine cervical cancer. The reproducibility of applicator position in the same patient at repeated treatments was very important for accurate dose delivery. It was aimed to evaluate the change of applicator location between each high dose rate(HDR) brachytherapy insertion in the patients with uterine cervical cancer. II. Materials and Methods From January 1999 to October 2001, total 52 patients were treated with external beam radiotherapy and HDR brachytherapy (Microselectron, Nucletron). During six to seven times of brachytherapy, all patients had three treatment plans. From the orthogonal radiographs, we measured the following variables; height from upper border of pubic bone to os (HPO), distance from sacral promontory to tip of tandem (DST), distance from coccyx to os (DCO), distance from tip of right ovoid to os (DRO), distance from tip of left ovoid to os (DLO), and distance from center of the first tandem source to ovoid (DTO). To evaluate the reproducibility of applicator position, it was calculated the standard deviation of differences between three insertions for the 7 parameters in each patient. III. Results The ranges of standard deviations of interfractional differences for the variables were as follows. 1)HPO : $0{\sim}0.79cm$ 2)DST : $0{\sim}0.9cm$ 3)DCO : $0.06{\sim}0.76cm$ 4)DRO : $0{\sim}0.53cm$ 5)DLO : $0{\sim}0.45cm$ 6) DTO $0{\sim}0.36cm$ IV. Conclusions There was some change in applicator position on repeated implants in our study. But variation of the interfractional differences was minimal; in all parameters, there were less than 1 cm. We are continued to try for reducing the geometric variation between each procedure.

  • PDF

Timestamps based sequential Localization for Linear Wireless Sensor Networks (선형 무선 센서 네트워크를 위한 시각소인 기반의 순차적 거리측정 기법)

  • Park, Sangjun;Kang, Jungho;Kim, Yongchul;Kim, Young-Joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1840-1848
    • /
    • 2017
  • Linear wireless sensor networks typically construct a network topology with a high reliability through sequential 1:1 mapping among sensor nodes, so that they are used in various surveillance applications of major national infrastructures. Most existing techniques for identifying sensor nodes in those networks are using GPS, AOA, and RSSI mechanisms. However, GPS or AOA based node identification techniques affect the size or production cost of the nodes so that it is not easy to construct practical sensor networks. RSSI based techniques may have a high deviation regrading location identification according to propagation environments and equipment quality so that complexity of error correction algorithm may increase. We propose a timestamps based sequential localization algorithm that uses transmit and receive timestamps in a message between sensor nodes without using GPS, AOA, and RSSI techniques. The algorithms for distance measurement between each node are expected to measure distance within up to 1 meter in case of an crystal oscillator of 300MHz or more.

Accuracy Analysis of 3D Position of Close-range Photogrammetry Using Direct Linear Transformation and Self-calibration Bundle Adjustment with Additional Parameters (DLT와 부가변수에 의한 광속조정법을 활용한 근접사진측량의 3차원 위치정확도 분석)

  • Kim, Hyuk Gil;Hwang, Jin Sang;Yun, Hong Sic
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.27-38
    • /
    • 2015
  • In this study, the 3D position coordinates were calculated for the targets using DLT and self-calibration bundle adjustment with additional parameters in close-range photogrammetry. And then, the accuracy of the results were analysed. For this purpose, the results of camera calibration and orientation parameters were calculated for each images by performing reference surveying using total station though the composition of experimental conditions attached numerous targets. To analyze the accuracy, 3D position coordinates were calculated for targets that has been identically selected and compared with the reference coordinates obtained from a total station. For the image coordinate measurement of the stereo images, we performed the ellipse fitting procedure for measuring the center point of the circular target. And then, the results were utilized for the image coordinate for targets. As a results from experiments, position coordinates calculated by the stereo images-based photogrammetry have resulted out the deviation of less than an average 4mm within the maximum error range of less than about 1cm. From this result, it is expected that the stereo images-based photogrammetry would be used to field of various close-range photogrammetry required for precise accuracy.

A Semantic Annotation Method for Efficient Representation of Moving Objects (이동 객체의 효과적 표현을 위한 시맨틱 어노테이션 방법)

  • Lee, Jin-Hwal;Hong, Myung-Duk;Lee, Kee-Sung;Jung, Jin-Guk;Jo, Geun-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.7
    • /
    • pp.67-76
    • /
    • 2011
  • Recently, researches for semantic annotation methods which represent and search objects included in video data, have been briskly activated since video starts to be popularized as types for interactive contents. Different location data occurs at each frame because coordinates of moving objects are changed with the course of time. Saving the location data for objects of every frame is too ineffective. Thus, it is needed to compress and represent effectively. This paper suggests two methods; the first, ontology modeling for moving objects to make users intuitively understandable for the information, the second, to reduce the amount of data for annotating moving objects by using cubic spline interpolation. To verify efficiency of the suggested method, we implemented the interactive video system and then compared with each video dataset based on sampling intervals. The result follows : when we got samples of coordinate less than every 15 frame, it showed that could save up to 80% amount of data storage; moreover, maximum of error deviation was under 31 pixels and the average was less than 4 pixels.

INDEPENDENT JAW를 이용한 인접한 HALF BEAM 조사야 경계에서 조작방법과 조작자에 따른 선량오차의 경향

  • 서정민;박용철;주상규
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.126-129
    • /
    • 2001
  • I. 목적 : Half beam을 이용하여 인접한 조사면 치료시, 경계부위에서 발생할 수 있는 Jaw Position에 의한 기하학적 오차는 정확한 선량전달에 문제를 일으킨다. 이에 본 저자는 QA용 필름을 이용하여 조사면 setting 방법과 조작자간의 오차를 분석하고 이를 최소화할 수 있는 방법을 찾고자 한다. II. 대상 및 방법 : 본 실험은 6MV선(CL2100C, Varian, USA)을 대상으로 하였으며, 폴리스틸렌팬톰($25{\times}25cm2$)을 SSD 100 cm으로 고정한 후, 측정용 필름(X-omat V2, Kodak, USA)을 5 cm 깊이에 위치 시켜 조사면의 중심에서 경계를 이루는 비대칭 조사면 ($0/7.5{\times}15,7.5/0{\times}15 cm$)을 쌍으로 조사하였다. 조사된 필름은 자동현상기를 이용하여 현상한 후 농도계(Densitometer, Multidata, USA)를 이용하여 중심축상에서의 농도분포를 측정하여 인접한 조사면에서의 오차를 분석하였다. 조작방법과 조작자간의 오차를 분석하기 위하여 5명의 방사선사를 대상으로 auto및 manual set-up을 실시하였고 각 방법의 평균 오차를 분석하기 위해 5회 반복하였다. III. 결과 : 필름 농도곡선을 이용하여 두 조사면이 만나는 경계에서의 오차를 분석한 결과, remote console set-up의 경우 주변 조사면에 비해 $-0.16{\pm}3.44\%$, pendant방식에서는 $+5.04{\pm}4.37\%$로 나타났고, 조작자간의 유의성이 관찰되었다. IV. 결론 : 비대칭 조사면을 이용한 근접 조사면의 치료시 pendant 방식보다 remote console 방식에서 오차가 적 게 나타나므로 Auto set-up 기능의 이용은 치료시에 조사면 경계에서의 선량 오차를 최소한으로 줄이는데 도움이 될 것으로 생각된다. 또한 manual 방식으로 set-up 시 오차의 편차가 크게 나타나므로 치료시에 세심한 주의가 필요할 것으로 사료된다.

  • PDF

Simulation Study of the Phosphoric Acid Fuel Cell Stack (인산형 연료전지 스택의 전산모사)

  • Choi, Sungwoo;Lee, Kab soo;Kim, Hwayong
    • Clean Technology
    • /
    • v.7 no.4
    • /
    • pp.243-250
    • /
    • 2001
  • The fuel cell has been continuously studied as environment-compatible alternative energy technology. Lately the basic techniques about stacking and widening are considered to be important for practical use. Although phosphoric acid fuel cell (PAFC) is the most progressed one in the fuel cell technologies, few studies about temperature profile of the stack which can be the basic data for the fuel cell design have been reported yet. In this study, the temperature profile of PAFC stack was simulated. The temperature profiles of stack were obtained at various operating conditions, and when stack is operated the proper position to measure the temperature could be predicted. Also we can propose more effective cooling design. The standard deviation of the temperature profile of the proposed design was is about 50% smaller.

  • PDF

Calibration Technique of Liquid Density Measurement using Magnetostriction Technology (자기 변형 기술을 이용한 액체 밀도 측정의 보정 기술)

  • Seo, Moogyo;Hong, Youngho;Choi, Inseoup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.178-184
    • /
    • 2014
  • In this study, we develop liquid density sensor by measuring of balanced position between gravity and bouyancy, corresponding to liquid density, using distance measuring by magnetostriction technology. For improvement of accuracy of liquid density sensor system. And we derive the related equation between liquid density and moving distance of density sensor, and make the calibration method for liquid density sensor by magnetostriction technology. Using fabricated liquid density sensing system and derived equation, have measured the density of several liquids. And compare it to measuring results using Oscillating U-tube type high accuracy density meter, having 0.000001 g/cc resolution. The deviation of results between two density measuring systems was less than 0.001 g/cc.

A goodness - of - fit test for the exponential distribution with unknown parameters (모수가 미지인 상황에서의 지수분포성 적합도 검정방법)

  • 김부용
    • The Korean Journal of Applied Statistics
    • /
    • v.4 no.2
    • /
    • pp.157-170
    • /
    • 1991
  • This article is concerned with the goodness - of - fit test for exponentiality when both the scale and location parameters are unknown. A test procedure based on the $L_1$-norm of discrepancy between the cumulative distribution function and the empirical distribution function is proposed, and the critical values of the test statistic are obtained by Monte Carlo simulations. Also the null distributions of the proposed test statistic are presented for small sample sizes. The power of tests under certain alternative distributions is investigated to compare the proposed test statistic with the well-known EDF test statistics. Our Monte Carlo power studies reveal that the proposed test statistic has good power properties, for moderate-to-large sample sizes, in comparison to other statistics although it is a conservative test.