• Title/Summary/Keyword: 원심입력

Search Result 30, Processing Time 0.021 seconds

2D Numerical Simulation of a Dynamic Centrifuge Test for a Pile-Supported Structure (2차원 수치해석을 이용한 말뚝 지지구조물의 동적 원심모형실험 거동 모사)

  • Chanh, Pham Viet;Tran, Nghiem Xuan;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.8
    • /
    • pp.15-26
    • /
    • 2018
  • Recently, as the seismic performance based design methods have been introduced, dynamic numerical analyses need to be performed to evaluate the actual performance of structures under earthquakes. The verification of the numerical modeling is the most important for the performance based design. Therefore, 2-dimensional numerical analyses were performed to simulate the seismic behavior of a pile-supported structure, to provide the proper numerical modeling and to determine of input parameters. A dynamic centrifuge test of a pile group in dry loose sand was simulated to verify the applicability of the numerical model. The numerical modeling was carefully made to reflect the actual condition of the centrifuge test including dynamic soil properties, soil-pile interaction, boundary condition, the modeling of the group pile and structure and so on. The predicted behavior of the numerical analyses successfully simulated the acceleration variation in ground, the moment and displacement of the pile, and the displacement and acceleration of the structure. Therefore, the adopted numerical modeling and the input parameters can be used to evaluate the seismic performance of pile groups.

Model Order Reduction for Piezoelectric-Structural Systems with Coriolis Effect (코리올리 효과를 가진 압전-구조계의 모델차수축소법)

  • Han, Jeong-Sam
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.713-716
    • /
    • 2010
  • 본 논문에서는 코리올리 효과를 가진 압전-구조 시스템의 주파수응답 해석을 효율적으로 수행하기 위한 크리로프 부공간 모델차수축소법을 제안하였다. 이 방법은 초기 유한요소모델과 축소모델의 전달함수의 계수인 모멘트를 일치시키는 방법을 이용하는 축소기법으로 이미 대형 유한요소모델의 주파수응답 해석에 효과적으로 이용되고 있다. 예제로 고려된 압전형 미소 각속도계의 해석에는 압전구동 하중과 구조체의 회전에 따른 원심력이 동시에 입력하중으로 고려되는 다중입력의 경우이므로 변환행렬 V의 생성시, block Arnoldi 과정을 이용하여 두 하중의 효과를 축소모델에 함께 고려한다. 본 문제에 제안된 축소기법을 이용한 결과, 축소모델을 이용하여 원래 시스템의 관심영역의 주파수응답을 작은 차수의 모델로도 정확하게 계산할 수 있음을 확인하였다. 본 논문에서 제안된 방법을 이용하면 다양한 가진조건과 각속도 입력 하에서의 주파수응답을 정확하고 더욱 효율적으로 계산할 수 있을 것이다.

  • PDF

Effects of Stiffness of Face Supporting Zone on Face Slab Behaviors of CFRD (CFRD 차수벽지지죤 강성이 콘크리트차수벽 거동에 미치는 영향)

  • Ha, Ik Soo;Seo, Min Woo;Kim, Hyoung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5C
    • /
    • pp.351-358
    • /
    • 2006
  • The purpose of this study is to recommend the simulation method and procedure of behaviors of CFRD(Concrete Faced Rockfill Dam) concrete face slab with impoundment by centrifuge tests, to examine the effects of the flexural rigidity of the concrete face slab on the face slab deformation from the centrifuge tests, and to evaluate the effects of the stiffness of face supporting zone on the displacement and moment of face slab by numerical analysis which is verified by the centrifuge tests. In this study, the centrifuge tests on the two model dams with the concrete face slab of different flexural rigidity were carried out. Also, the centrifuge tests were simulated by numerical analysis of which input material properties were obtained by the triaxial tests on the model materials. The validity of numerical analysis was evaluated by comparison between the results of centrifuge tests and numerical simulation. The deformation pattern of the concrete face slab was examined with the various stiffness of the face supporting zone by numerical analysis. From the results of centrifuge tests, the effects of face slab thickness on the deformation of face slab were negligible. From the results of centrifuge tests and numerical analysis, it was found that the amplitude of the maximum displacement of face slab and the position where the maximum displacement was mobilized with impoundment were affected by the stiffness of face supporting zone rather than the flexural rigidity of concrete face slab.

Evaluation of the Numerical Liquefaction Model Behavior with Drainage Condition (배수조건에 따른 액상화 수치모델의 거동평가)

  • Lee, Jin-Sun;Kim, Seong-Nam;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.11
    • /
    • pp.63-74
    • /
    • 2019
  • Numerical liquefaction model and response history analysis procedure are verified based on dynamic centrifuge test results. The test was a part of the Liquefaction Experiments Analysis Project (LEAP). The model ground was formed inside of rigid box by using the submerged Ottawa F65 sand with a relative density of 55% and 5° of surface inclination. A tapered sinusoidal wave with a frequency of 1 Hz was applied to the base of the model box. Numerical analyses were performed by two dimensional finite difference method in prototype scale. The soil is modeled to show hysteretic behavior before shear failure, and Mohr-Coulomb model is applied for shear failure criterion. Byrne's liquefaction model was applied to track the changes in pore pressure due to cyclic loading after static equilibrium. In order to find an appropriate flow condition for the liquefaction analysis, numerical analyses were performed both in drained and undrained condition. The numerical analyses performed under the undrained condition showed good agreement with the centrifuge test results.

The Design Review for Lubrication System of an Internal Combustion Engine (내연기관 윤활시스템의 설계검증)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.26 no.3
    • /
    • pp.175-183
    • /
    • 2010
  • It is not too much to say that, at the beginning of engine development, the most important areas for a good engine concept design is the lubrication system design. So, between right after finishing concept design and before procuring the engine, it is necessary to carry out the system lubrication analysis for the initially designed lubrication system and the related lubricating parts. Therefore, in this paper, it is to describe the results of a design review carried out the numerical net work analysis on the engine bearings and the lubrication system of an initially designed 2.0 L DOHC engine.

Evaluation of the Seismic Integrity of a Centrifugal Pump using Response Spectrum Analysis (응답 스펙트럼 해석을 이용한 원심펌프의 내진 건전성 평가)

  • Choi, Myung-Jin;Yoo, Ji-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.44-50
    • /
    • 2010
  • Vibration responses of a centrifugal pump required dynamic analysis for seismic qualification, were calculated by using spectrum analysis, which is known to be very simple compared with time domain analysis. Modal analysis was performed and the results were utilized in the spectrum analysis. The vibration responses calculated from the spectrum analysis were more conservative than those from the time domain analysis, that is, the former can be used as safer in design process. The pump was qualified for the specified seismic service conditions as specified in IEEE 344-1987. The maximum stresses were less than allowable stress limits. Based on the analysis results, it is concluded that the pump meets all the dynamic requirements of the applicable codes, standards, and technical specification.

Evaluation of Rocking Behaviors During Earthquake for the Shallow Foundation System on the Weathered Soil Using Dynamic Centrifuge Test (동적 원심모형실험을 이용한 풍화토 지반에 놓인 얕은기초 시스템의 지진 시 회전 거동 특성 평가)

  • Ha, Jeong-Gon;Jo, Seong-Bae;Park, Heon-Joon;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.6
    • /
    • pp.5-16
    • /
    • 2017
  • Rocking behavior of shallow foundation during the earthquake can reduce the seismic load of the superstructure. The dynamic centrifuge tests were performed to investigate the availability of using rocking behavior for the weathered soil condition. The centrifuge test model was composed of the weathered soil, shallow foundation and single degree of freedom structure. And the accelerations of soil, foundation and structure, and the foundation settlement were measured during the earthquake. From the test result, the seismic load of the structure for the strong earthquake input was reduced by the rocking behavior with foundation uplift and the maximum foundation settlement was less than 0.5% of the foundation width. This shows the potential that the rocking foundation concept can be used in the economical seismic design of foundation for the weathered soil in the future with additional research and verification.

Foundation-soil-foundation Interaction of Shallow Foundations Using Geo Centrifuge: Experimental Approach (원심모형실험을 이용한 얕은 기초의 기초-지반-기초 상호작용: 실험적 접근)

  • Ngo, Linh Van;Kim, Jae-Min;Lim, Jaesung;Lee, Changho
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.1
    • /
    • pp.25-35
    • /
    • 2018
  • Geocentrifuge tests are performed to investigate the structure-soil-structure interaction of shallow foundations that have various sizes. The soil specimen is prepared by using the air-pluviation, and the dynamic responses of the foundation are monitored with separation distances between the two foundations and the embedment. During the centrifugal test, the measured ground acceleration shows a tendency to increase with the increase of the input seismic amplitude, and maximum acceleration is measured at the surface due to the ground amplification. As the separation distance between the two foundations decreases, the ratio of the response spectral acceleration (RRS) increases and the period at the peak RRS decreases due to the structure-soil-structure interaction (SSSI). The RRS of the two foundations tends to decrease when the foundations are buried in the ground at the same separation distance.

Improvement in flow and noise performance of backward centrifugal fan by redesigning airfoil geometry (익형 형상 재설계를 통한 후향익 원심팬의 유동 및 소음성능 개선)

  • Jung, Minseung;Choi, Jinho;Ryu, Seo-Yoon;Cheong, Cheolung;Kim, Tae-hoon;Koo, Junhyo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.555-565
    • /
    • 2021
  • The goal of this study is to improve flow and noise performances of existing backward-curved blade centrifugal fan system used for circulating cold air in a refrigerator freezer by optimally designing airfoil shape. The unique characteristics of the system is to drive cold airflow with two volute tongues in combination with duct system in a back side of a refrigerator without scroll housing generally used in a typical centrifugal fan system. First, flow and noise performances of existing fan system were evaluated experimentally. A P-Q curve was obtained using a fan performance tester in the flow experiment, and noise spectrum was measured in an anechoic chamber in the noise experiment. Then, flow characteristics were numerically analyzed by solving the three-dimensional unsteady Navier-Stokes equations and noise analysis was performed by solving the Ffowcs Williams and Hawkins equation with input from the flow simulation results. The validity of numerical results was confirmed by comparing them with the measured ones. Based on the verified numerical method, blade inlet and outlet angles were optimized for maximum flow rate using the two-factor central composite design of the response surface method. Finally, the flow and noise performances of a prototype manufactured with the optimum design were experimentally evaluated, which showed the improvement in flow and noise performance.

Numerical Simulation of Dynamic Soil-pile Interaction for Dry Condition Observed in Centrifuge Test (원심모형실험에서 관측된 건조 지반-말뚝 동적 상호작용의 수치 모델링)

  • Kown, Sun-Yong;Kim, Seok-Jung;Yoo, Min-Taek
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.4
    • /
    • pp.5-14
    • /
    • 2016
  • Numerical simulation of dynamic soil-pile-structure interaction embedded in a dry sand was carried out. 3D model of the dynamic centrifuge model tests was formulated in a time domain to consider nonlinear behavior of soil using the finite difference method program, FLAC3D. As a modeling methodology, Mohr-Coulomb criteria was adopted as soil constitutive model. Soil nonlinearity was considered by adopting the hysteretic damping model, and an interface model which can simulate separation and slip between soil and pile was adopted. Simplified continuum modeling (Kim et al., 2012) was used as boundary condition to reduce analysis time. Calibration process for numerical modeling results and test results was performed through the parametric study. Verification process was then performed by comparing numerical modeling results with another test results. Based on the calibration and validation procedure, it is identified that proposed modeling method can properly simulate dynamic behavior of soil-pile system in dry condition.