Abstract
Vibration responses of a centrifugal pump required dynamic analysis for seismic qualification, were calculated by using spectrum analysis, which is known to be very simple compared with time domain analysis. Modal analysis was performed and the results were utilized in the spectrum analysis. The vibration responses calculated from the spectrum analysis were more conservative than those from the time domain analysis, that is, the former can be used as safer in design process. The pump was qualified for the specified seismic service conditions as specified in IEEE 344-1987. The maximum stresses were less than allowable stress limits. Based on the analysis results, it is concluded that the pump meets all the dynamic requirements of the applicable codes, standards, and technical specification.
내진 평가에서 동적 해석이 필요한 원심펌프에 대하여, 시간 이력 해석에 비해 간편한 스펙트럼 해석을 이용하여, 진동 응답을 산출하였다. 유한요소법에 의하여 모드 해석을 하였으며, 모드 해석 결과에 입각하여 스펙트럼 해석을 수행하였다. 스펙트럼 해석에 의해 구해진 진동 응답은 시간 이력 해석의 결과보다 보수적으로 산출되어 안전하게 설계할 수 있음을 알 수 있었다. 본 연구에서의 펌프는 IEEE 344-1987에서 요구되는 조건에 따라 내진 구조 건전성이 평가 되었다. 각 부재의 최대 응력은 허용 응력이하로 산출되었으며, 펌프는 주어진 지진 입력에 대하여 요구되는 안전 조건을 구비하고 있음이 판명되었다.