• Title/Summary/Keyword: 원심성 펌프

Search Result 29, Processing Time 0.022 seconds

화학공장용 프로세스 펌프의 특성

  • 이동양
    • Journal of the KSME
    • /
    • v.28 no.1
    • /
    • pp.37-41
    • /
    • 1988
  • 일반적으로 화학공장에서 요구되는 프로세스 펌프는 취급하는 액의 물리적 화학적 성질 및 고 형체(solid)함량, 결정생성 여부 등을 고려 이에 충분히 견디고 유지보수가 용이하며 가격 면에 서도 저렴하고 여러 가지 운전 조건에 상응할 수 있는 호환성 있는 제품이어야 한다. 다양한 액성 및 운전조건에 적합한 펌프 선정에는 실제적인 많은 시험과 경험이 필요하다. 본 글에서는 원심펌프 선정시 보편적으로 고려되어야 할 일반사항에 대하여 기술하고자 한다.

  • PDF

Postcardiotomy Ventricular Support with Biomedicus Pump (Biomedicus pump를 이용한 개심술후 심실보조)

  • Kim, Won-Gon;Lee, Chang-Ha;Kim, Ki-Bong;Ahn, Hyuk;Rho, Ryang-Joon
    • Journal of Chest Surgery
    • /
    • v.29 no.11
    • /
    • pp.1218-1222
    • /
    • 1996
  • The reported incidence of postcardiotomy cardiogenic shock not responding to conventional therapy is still 0.1 to 0.8%. For this group of patients, more aggressive form of circulatory support must be employed. Centrifugal pumps are a ventricular assist device most commonly used on this purpose, due to low cost and easy availability. Currently, however, clinical experience of centrifugal pumps as a ventricular assist device is rarely reported in Korea. From January 1992 to January 1996, 2986 patients underwent cardiac operations on cardiopulmonary bypass at Seoul National University Hospital. Refractory postcardiotomy cardiac failure requring ventricular support with a Biomedicus centrifugal pump developed in ten of these patients. There were eight men and two women, ranged in age from nine years to 77 years with a mean of 50$\pm$20 years. The primary surgical procedures consisted of isolated coronary revascularization in four patients, combined coronary revascularization and aortic valve replacement in two, aortic dissection repair in two, pulmonary embolectomy in one, and heart transplantation in one. Of the ten patients, five had left ventricular assistance, one had right ventricular assistance, and four had biventricular assistance. Duration of ventricular assistance ranged from 24 to 175 hours, with a mean of 76$\pm$51 hours. Seven patients were weaned from ventricular assistance, and four of them discharged. The causes of death for nonsurvivors were progressive cardiac failure in two patients and multiorgan failure, intractable ventricular fibrillation, irreversible brain injury, and mechanical problem, respectively, in the other four. Survival was not predicted by time on cardiopulmonary bypass, aortic cross-clamp time, or duration of ventricular support. Major complications included bleeding(7), renal failure(6), infection(3) and neurologic complication(2). These results indicate that a centrifugal pump can provide reasonably satisfactory short-term circulatory support.

  • PDF

Optimization of impeller blade shape for high-performance and low-noise centrifugal pump (고성능 저소음 원심펌프 개발을 위한 임펠러 익형 최적설계)

  • Younguk Song;Seo-Yoon Ryu;Cheolung Cheong;Tae-hoon Kim;Junhyo Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.519-528
    • /
    • 2023
  • The aim of this study was to enhance the flow rate and noise performance of a centrifugal pump in dishwashers by designing an optimized impeller shape through numerical and experimental investigations. To evaluate the performance of the target centrifugal pump, experiment was conducted using a pump performance tester and noise experiment was carried out in a semi-anechoic chamber with microphones and a reflecting wall behind the dishwasher. Through the use of advanced computational fluid dynamics techniques, numerical simulations were performed to analyze the flow and aeroacoustics performance of our target centrifugal pump impeller. To achieve this, numerical simulations were carried out using the Reynolds-Average Navier-Stokes equations and Ffowcs-Willliams and Hawkings equations as governing equations. In order to ensure the validity of numerical methods, a thorough comparison of numerical results with experimental results. After having confirmed the reliability of the current numerical method of this study, the optimization of the target centrifugal pump impeller was conducted. An improvement in flow rate was confirmed numerically, and a manufactured proto-type of the optimized model was used for experimental investigation. Furthermore, it was observed that by applying the fan law, we could effectively reduce noise levels without reducing the flow rate.

Short-term Mechanical Circulatory Support with Centrifugal Pump in Cardiac Arrest or Cardiogenic Shock - Report of 5 cases- (심정지 혹은 심인성 쇼크에서 원심성 펌프를 이용한 단기목표의 기계적 순환 보조)

  • 양희철;성기익;뱍계현;전태국;박표원;양지혁;이영탁
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.1003-1009
    • /
    • 2004
  • Mechanical circulatory support (MCS) has been used for myocardium failure, but moreover, it may be essential for the life support in cardiac arrest or cardiogenic shock. Many commercial devices can be used effectively for the long-term support. However, there are some limitations in the aspects of the cost and technical support by production company. Short-term support with centrifugal type has been reported numerously with the purpose of bridging to heart transplantation or recovery. We successfully treated 5 patitents who were in the status of cardiogenic shock (n=3) or arrest (n=2) with the technique of extracorporeal life support system (ECLS) or left ventricular assist device (LVAD) using the centrifugal type pump. The MCS were performed emergently (n=2) under cardiac arrest caused by ischemic heart disease, and urgently (n=3) under cardiogenic shock with ischemic heart disease (n=1) or acute fulminant viral myocarditis (n=2). All patients were weaned from MCS. Complications related to the use of MCS were bleeding and acute renal failure, but there were no major complications related to femoral cannulations. Mechanical circulatory support may be essential for the life support and rescue in cardiac arrest or cardiogenic shock.

Evaluation of the Seismic Integrity of a Centrifugal Pump using Response Spectrum Analysis (응답 스펙트럼 해석을 이용한 원심펌프의 내진 건전성 평가)

  • Choi, Myung-Jin;Yoo, Ji-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.44-50
    • /
    • 2010
  • Vibration responses of a centrifugal pump required dynamic analysis for seismic qualification, were calculated by using spectrum analysis, which is known to be very simple compared with time domain analysis. Modal analysis was performed and the results were utilized in the spectrum analysis. The vibration responses calculated from the spectrum analysis were more conservative than those from the time domain analysis, that is, the former can be used as safer in design process. The pump was qualified for the specified seismic service conditions as specified in IEEE 344-1987. The maximum stresses were less than allowable stress limits. Based on the analysis results, it is concluded that the pump meets all the dynamic requirements of the applicable codes, standards, and technical specification.

IV. 원심펌프 회전축계의 불평형응답에 미치는 유체력의 영향

  • 양보석;최원호
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1986.06a
    • /
    • pp.26-29
    • /
    • 1986
  • 회전축계의 강제진동으로 가장 전형적이고 공업상 중요한 것은 넓은 의미로서 불평형 진동이다. 불평형은 회전체의 제작상 피할 수 없으며 진동이 전혀 문제가 되지 않는 정도로 제작하는 것은 경제적인 면에서도 불가능하다. 지금까지 미끄럼 베어링으로 지지된 회전축계의 불평형 응답 특성에 대하여는 여러 연구자에 의해 연구가 진행되고 있다. 수중에서 운전되는 펌프는 물의 감쇠작용 때문에 축진동 문제는 적다고 생각되어 펌프의 축진동에 관한 보고는 별로 없다. Black은 펌프의 축진동을 연구하여, 시일부분이 축진동 응답에 큰 영향을 미치는 것을 보였다. 그러나 시일형상에 따른 유체력 평가가 충분히 구명되지 않았기 때문에 환상 시일부분의 틈새,폭경비 및 압력차 등이 펌프진동에 어느 정도 영향을 미치는가가 충분히 검토 되어 있지않다. 이에 저자는 펌프용 시일의 유체력에 의한 진동 특성에 관한 일련의 연구를 진행하여 각종 시일의 유체력을 해석하였고, 이 유체력이 회전축계의 안정성에 미치는 영향을 검토하였으며 범용 안정성해석 프로그램을 개발하였다.

  • PDF

Investigation on the Strength and Vibration Safety of the Liquid Rocket Turbopump Turbine (액체로켓 터보펌프 구동터빈의 구조 강도 및 진동 안전성에 관한 연구)

  • Jeon,Seong-Min;Kim,Jin-Han;Lee,Dae-Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.8
    • /
    • pp.77-84
    • /
    • 2003
  • Structural analyses of a turbine bladed-disk for a liquid rocket turbopump are peformed to investigate the safety level of strength and vibration at design point. Due to the high rotational speed of the turbopump, effects of centrifugal forces are carefully considered in the structural analysis. Thermal load caused by extreme temperature distribution is also considered as an external force applied to turbine bladed-disk. A three dimensional finite element method (FEM) is used for cyclic symmetry structural analyses with the MSC/NASTRAN DMAP Alter. Interblade phase angles are considered to investigate structural dynamic characteristics as a function of rotational speed. Through the numerical analysis, effects of centrifugal and thermal loads on the turbine bladed-disk are examined.

Development of Drainage Pump for Rescue Sinking Ship (침수선박 구조를 위한 대용량 배수펌프 개발)

  • Kim, Kyeong-Soo;Jung, Kang-Hyun;Kim, Hae-Young;Kim, Nam-Hun;Cho, Je-Hyoung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.248-254
    • /
    • 2015
  • There has been no previous study on technology development of large capacity drainage pump for rescue sinking ship in the country. The agricultural drainage pump was widely used for rescue sinking ship but this pump has several problems such as efficiency, low displacement and malfunction in winter. Therefore, this paper proposes to solve the problems for swiftly rescue sinking ship and develops the drainage pump system that has $20m^3/min$ mass flow rate specification at suction head 8 m. The centrifugal pump type the most commonly used in the field of naval architecture and ocean engineering was selected and designed based on the requirement specification. The blade design of impeller was derived from the Stepanoff coefficient and requirement specification and used computational fluid dynamics to review the target mass flow rate according to the impeller RPM at design operating conditions. We also performed structure analysis of the impeller to find structurally vulnerable points for the pump in service and completed the theoretical design of drainage pump system.