Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF

A Study on Image Acquisition of Gamma Camera using Simulation LUT and MLPE (시뮬레이션 순람표와 최대우도함수를 이용한 감마카메라의 영상 획득 연구)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.409-414
    • /
    • 2021
  • In order to acquire an image from a gamma camera, linearity correction must be performed. To this end, digital coordinates are acquired by using a linearity map to accurately specify the location where the scintillator and gamma rays interact. In this study, a method for acquiring undistorted images and digital coordinates was developed using a lookup table and maximum likelihood position estimation without using a linearity map. The proposed method was verified by configuring a small gamma camera through DETECT2000 simulation. A gamma camera was constructed using a GAGG scintillator and a SiPM optical sensor, and a gamma-ray interaction was generated at the center of the scintillator, and a lookup table was prepared using the ratio of the signals obtained from the SiPM. Through the prepared lookup table and the maximum likelihood position estimation, the position of the signal obtained by the gamma-ray interaction was acquired as digital coordinates to compose an image. As a result, the linearity was maintained compared to the generally acquired image, the accuracy of the location where the gamma-ray interaction was generated was excellent, and the distance between the locations was uniform. Since the lookup table obtained through simulation is created using the ratio of the signal, it can be directly used in the experiment, and the position of the signal can be conveniently obtained with digital coordinates with corrected linearity without creating a linearity map.

Modeling the Effect of Consideration Set-Based Reference Price: Empirical Bayes & Latent Class Approach (고려상품군을 반영한 준거가격효과의 모형화: Empirical Bayes & Latent Class Approach)

  • Chang, Kwangpil
    • Asia Marketing Journal
    • /
    • v.8 no.1
    • /
    • pp.1-17
    • /
    • 2006
  • A couple of previous studies have warned against the use of homogeneous choice models in assessing the effect of reference price since unaccounted for response heterogeneity may result in spurious reference price effects(Chang, Siddarth and Weinberg 1999; Bell and Lattin 2000). According to Meyer and Kahn(1991), not accounting for consideration set heterogeneity may also bias the effect parameters in the choice model. Therefore, failure to account for these two sources of bias, in fact, have cast doubt on the empirical support for reference price effects in general. In view of aforementioned potential sources of bias, the author investigates the robustness of loss aversion effect in the reference-dependent model after accounting for heterogeneity in response as well as consideration set. The proposed model defines individual household's consideration set based on the posterior distribution of preference obtained from the Empirical Bayes approach. In addition, the same posterior distribution is used to form household-specific reference prices. Response heterogeneity correction is carried out via the Latent Class approach. The proposed model outperforms the Reference-Dependent model that includes the reference price measure most often employed in the previous studies. This implies that as a way of simplifying decision task, consumers restrict their consideration set to a subset of available brands not only in making a brand choice but also in forming reference prices.

  • PDF

Correction for SPECT image distortion by non-circular detection orbits (비원형 궤도에서의 검출에 의한 SPECT 영상 왜곡 보정)

  • Lee, Nam-Yong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.156-162
    • /
    • 2007
  • The parallel beam SPECT system acquires projection data by using collimators in conjunction with photon detectors. The projection data of the parallel beam SPECT system is, however, blurred by the point response function of the collimator that is used to define the range of directions where photons can be detected. By increasing the number of parallel holes per unit area in collimator, one can reduce such blurring effect. This approach also, however, has the blurring problem if the distance between the object and the collimator becomes large. In this paper we consider correction methods for artifacts caused by non-circular orbit of parallel beam SPECT with many parallel holes per detector cell. To do so, we model the relationship between the object and its projection data as a linear system, and propose an iterative reconstruction method including artifacts correction. We compute the projector and the backprojector, which are required in iterative method, as a sum of convolutions with distance-dependent point response functions instead of matrix form, where those functions are analytically computed from a single function. By doing so, we dramatically reduce the computation time and memory required for the generation of the projector and the backprojector. We conducted several simulation studies to compare the performance of the proposed method with that of conventional Fourier method. The result shows that the proposed method outperforms Fourier methods objectively and subjectively.

  • PDF

Implementation on the Urine Analysis System using Color Correction and Chromaticity Coordinates Transform Methods (색 보정 및 색 좌표 변환 기법을 이용한 요분석 시스템의 구현)

  • 김기련;예수영;손정만;김철한;정도운;이승진;장용훈;전계록
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • A transformation methode of the chromaticity coordinates was proposed to calibrate the measured data obtained by a urine analysis system which implemented in our previous study. Generally. the reacted color of a reagent strip by urine analysis system often exhibit the color distortions due to nonlinear characteristics of the various devices that is the optic module mechanism. hardware, and surround circumstance. A color correction method for minimizing the color distortion play a few role in maintaining high accuracy and reproduction of the urine analysis system. In this work, we used the compensation method such as the shading correction, the characteristic curve extraction of RGB color by means of third order spline interpolation, and linear transformation using a reference color. In addition, 1931 CIE XYZ color space was used to compensate the color of the measured data by a standard reference system as colorimeter. A compensation matrix was obtained so that the output values of the urine analysis system is nearly equal to that of a standard reference system for identical color sample. Color correction obtained by a urine analysis system which implemented in our previous study exhibited a good color accuracy when it was compared with the reference data. Observed result from an experiments on ten items or a urinalysis strip that color difference or between two urine analysis system was 1.28.

A System for Concurrent TMS-fMRI and Evaluation of Imaging Effects (동시 뇌경두개자기자극-기능자기공명영상 시행을 위한 홀더 제작과 시뮬레이션 및 영상 데이터 평가)

  • Kim, Jae-Chang;Kyeong, Sunghyon;Lee, Jong Doo;Park, Hae-Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.169-180
    • /
    • 2013
  • Purpose : The purpose of this study was to setup a concuurent transcranial magnetic stimulation (TMS)-functional MRI (fMRI) system for understanding causality of the functional brain network. Materials and Methods: We manufactured a TMS coil holder using nonmagnetic polyether ether ketone (PEEK). We simulated magnetic field distributions in the MR scanner according to TMS coil positions and angles. To minimize image distortions caused by TMS application, we controlled fMRI acquisition and TMS sequences to trigger TMS during inter-volume intervals. Results: Simulation showed that the magnetic field below the center of the coil was dramatically decreased with distance. Through the MR phantom study, we confirmed that TMS application around inter-volume acquisition time = 100 miliseconds reduced imaging distortion. Finally, the applicability of the concurrent TMS-fMRI was tested in preliminary studies with a healthy subject conducting a motor task within TMS-fMRI and passive motor movement induced by TMS in fMRI. Conclusion: In this study, we confirmed that the developed system allows use of TMS inside an fMRI system, which would contribute to the research of brain activation changes and causality in brain connectivity.

Development of the Railway Abrasion Measurement System using Camera Model and Perspective Transformation (카메라 모델과 투시 변환에 의한 레일 마모도 측정 시스템 개발)

  • Ahn, Sung-Hyuk;Kang, Dong-Eun;Moon, Hyoung-Deuk;Park, So-Yeon;Kim, Man-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1069-1077
    • /
    • 2008
  • The railway abrasion measurement system have to satisfy two conditions to increase the measurement accuracy as follows. The laser region which is projected on the rail have to be extracted without the geometrical distortion. The mapping of the acquired laser region data on the rail profile have to be processed exactly. But, the conventional railway abrasion measurement system is deeply effected by the foreign substance( dust, rainwater, and so on ) on the railway or the sensitive response characteristic of the laser to the external measurement circumstance, and then the measurement errors arise from above factors. When the laser region is projected on the rail extracts from the acquired image, the interference of the light with the same frequency as the laser system occurs the serious problems. In the process of the mapping between the railway profile and the extracted laser region, the measurement accuracy is very highly effected by the geometrical distortion and the abnormal variation. In this Paper, we propose the novel method to increase the accuracy of the railway abrasion measurement dramatically. we designed and manufactured the high precision and fast image processing board with DSP Core and FPGA to measure the railway abrasion. The image processing board has the capability that the image of 1024X1280 from camera can be processed with the speed of 480 frame/sec. And, we apply the image processing algorithm base on the wavelet to extract the laser region is projected on the rail exactly. Finally, we developed high precision railway abrasion measurement system with the error range less than +/-0.5mm by which 2D image data is covered 3D data and mapped on the rail profile using the camera model and the perspective transform.

  • PDF

Exploring the Factors Influencing on the Accuracy of Self-Reported Responses in Affective Assessment of Science (과학과 자기보고식 정의적 영역 평가의 정확성에 영향을 주는 요소 탐색)

  • Chung, Sue-Im;Shin, Donghee
    • Journal of The Korean Association For Science Education
    • /
    • v.39 no.3
    • /
    • pp.363-377
    • /
    • 2019
  • This study reveals the aspects of subjectivity in the test results in a science-specific aspect when assessing science-related affective characteristic through self-report items. The science-specific response was defined as the response that appear due to student's recognition of nature or characteristics of science when his or her concepts or perceptions about science were attempted to measure. We have searched for cases where science-specific responses especially interfere with the measurement objective or accurate self-reports. The results of the error due to the science-specific factors were derived from the quantitative data of 649 students in the 1st and 2nd grade of high school and the qualitative data of 44 students interviewed. The perspective of science and the characteristics of science that students internalize from everyday life and science learning experiences interact with the items that form the test tool. As a result, it was found that there were obstacles to accurate self-report in three aspects: characteristics of science, personal science experience, and science in tool. In terms of the characteristic of science in relation to the essential aspect of science, students respond to items regardless of the measuring constructs, because of their views and perceived characteristics of science based on subjective recognition. The personal science experience factor representing the learner side consists of student's science motivation, interaction with science experience, and perception of science and life. Finally, from the instrumental point of view, science in tool leads to terminological confusion due to the uncertainty of science concepts and results in a distance from accurate self-report eventually. Implications from the results of the study are as follows: review of inclusion of science-specific factors, precaution to clarify the concept of measurement, check of science specificity factors at the development stage, and efforts to cross the boundaries between everyday science and school science.

A Study on the Digital Video Frame Obfuscation Method for Intellectual Property Protection (저작권 보호를 위한 디지털 비디오 화면 모호화 기법에 관한 연구)

  • Boo, Hee-Hyung;Kim, Sung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • In this paper, we propose the digital video frame obfuscation method for intellectual property protection using the DC component of the intra frame and the motion vector of the inter frame at digital video encoding. The proposed method considers characteristics of the HVS (human visual system) which is sensitive at the low frequency and the middle frequency. This method makes the signal distorted as operating XOR between authentication signal and the DC coefficient of the intra frame including main information and the sign of the motion vector including edge motion, so that the video is normally displayed only when suitable authentication signal is applied.

표면효과에 의한 Si 나노와이어의 전류 전압 특성

  • Park, Seong-Ju;Go, Jae-U;Lee, Seon-Hong;Baek, In-Bok;Lee, Seong-Jae;Jang, Mun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.409-409
    • /
    • 2012
  • 최근 나노크기의 미세구조 가공기술이 발달함에 따라 다양한 응용을 위한 나노소재/구조가 활발히 연구 되고 있다[1]. 그 중에서 실리콘 나노선은 태양전지, 메모리, 트랜지스터 그리고 광 공진기에 쓰일 수 있는 소재로서 기존의 실리콘 가공기술을 바로 사용할 수 있을 뿐 아니라[2], 비용 면에서 탁월한 잇점이 있기 때문에 주목 받고 있는 소재이다. 실리콘 나노선의 물리적 특성을 연구하기 위한 많은 연구가 진행되었지만, 매우 작은 크기와 높은 표면적-부피비율로 인해 생긴 독특한 특징을 완전히 이해하기에는 아직 부족한 점이 많다. 실리콘 나노선의 전류-전압특성에 영향을 미치는 요소는 도핑농도, 표면상태, 채널의 크기 등으로 다양한데, 이번 연구에서는 실리콘 나노선의 표면환경이 공기와 물 두 종류로 매질에 접하고 있을 경우에 대하여 각각 전류-전압을 측정하였다. 물이 공기와 다른 점은 크게 두 가지로 볼 수 있다. 첫째로 물의 경우에는 물에 용해된 수소이온과의 화학반응을 통하여 실리콘 표면전하가 유도되며 pH 값에 민감하게 변화한다. 둘째로 물의 유전율은 공기의 80배로서 표면부근에서의 전기장분포가 많이 왜곡된다. 이를 위하여 SOI를 기반으로 채널길이 $5{\mu}s$, 두께 40 nm, 너비 100 nm인 실리콘 나노선을 일반적인 반도체공정을 사용하여 제작하였다. 나노선의 전기적 특성 실험은 Semiconductor Parameter Analyzer (Agilent, 4155C)를 사용하여 전류-전압특성을 표면 상태를 변화시키면서 측정하였다. 실험을 통해 실리콘 나노선은 물과 공기 두 가지 표면환경에 따라 전류-전압특성이 확연히 변화하는 것을 볼 수 있었다. 동일한 전압 바이어스에서 표면에 물이 있을 때가 공기 있을 때 보다 훨씬 증가한 전류를 얻을 수 있었고(3V에서 약 2배), 비선형적인 전류-전압특성이 나타남을 관찰하였다. 본 발표에서는 이러한 실험결과를 표면에서의 전하와 정전기적인 효과로서 정성적으로 설명하고, 전산모사결과와 비교분석 하고자 한다.

  • PDF