Analysis of the Effect of Bio-Retention Cells to Improve Water Cycle and Water Quality in Urban Streams (도시하천의 물순환 및 수질 개선을 위한 생태저류지의 효과분석)

  • Kim, Kyungmin;Choi, Jeonghyeon;Kim, Suhyeon;Kang, Lim-Seok;Shin, Hyunsuk;Kim, Sangdan
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.224-235
    • /
    • 2019
  • Rapid urbanization poses three major problems in urban streams. The first problem is the reduction of soil wetting from rainfall as the impervious area increases. Decrease in soil wetting causes serious distortion in the water cycle of urban streams. The second problem is the increase of non-point sources pollutants by urban land use, and the third problem is the combined sewer overflows in the old city center. Increased non-point sources pollutants and combined sewer overflows are associated with water cycle distortion, which increases water pollution in urban streams. In this study, EPA SWMM was constructed for the Busan Oncheon-stream watershed in order to suggest solutions for these three problems, and the bio-retention cells installation project was planned by benchmarking the actual projects in New York City. Water cycle improvement and reduction of non-point sources pollutants and combined sewer overflows for each project scenario were analyzed together with required budgets.

Water Level and Quality Variations of CO2-rich Groundwater and Its Surrounding Geology in the Chungju Angseong Spa Area, South Korea: Considerations on Its Sustainability (충주 앙성지역 탄산천의 수위/수질 변동과 주변 지질 특성: 탄산천의 지속가능성에 대한 고찰)

  • Moon, Sang-Ho;Kee, Weon-Seo;Ko, Kyung-Seok;Lee, Cholwoo;Choi, Hanna;Koh, Dong-Chan
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.477-495
    • /
    • 2022
  • This study examined the sustainability of CO2-rich water by analyzing the water level and water quality change pattern with the amount of its use in Angseong area, Chungju. The origin and supply of CO2 component were discussed in consideration of 87Sr/86Sr ratio, occurrence of CO2-rich fluid inclusions in nearby W-Mo deposits and other surrounding geological characteristics. According to the data from 1986 to 2017, the depth of the water level of CO2-rich water was significantly lowered in the late period (2009-2015) than in the early period (1986-1992) of the development of hot spa wells, and the optimal yields for pumping tests also showed a tendency to gradual decrease. Concentrations of CO2 component also decreased continuously in the later stages compared to the early stages of development, but it has been stable since 2012. It is inferred that the geological environment related to forming W-Mo quartz vein deposits (0.5×1.5×several km) around the study area are largely involved in the origin and supply of CO2 component, and the supply of CO2 component is not infinitely supplied from deep current magma activity. Rather, since it is finitely supplied from a restricted subsurface region formed in the past geological period, it is necessary to efficiently control its use in order to maintain the sustainability of CO2-rich water in the study area.

Thermal Effluent Effects of Domestic Sewage and Industrial Wastewater on the Water Quality of Three Small Streams (Eung, Chiljang and Buso) during the Winter Season, Korea (동계 저온기의 소하천 수질에 미치는 하·폐수의 온배수 영향)

  • Soon-Jin, Hwang;Jeon, Gyeonghye;Eum, Hyun Soo;Kim, Nan-Young;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.2
    • /
    • pp.238-253
    • /
    • 2017
  • The sewage and wastewater (SAW) are a well-known major source of eutrophication and greentide in freshwaters and also a potential source of thermal pollution; however, there were few approaches to thermal effluent of SAW in Korea. This study was performed to understand the behavioral dynamics of the thermal effluents and their effects on the water quality of the connected streams during winter season, considering domestic sewage, industrial wastewater and hot spring wastewater from December 2015 to February 2016. Sampling stations were selected the upstream, the outlet of SAW, and the downstream in each connected stream, and the water temperature change was monitored toward the downstream from the discharging point of SAW. The temperature effect and its range of SAW on the stream were dependent not only on the effluent temperature and quantity but also on the local air temperature, water temperature and stream discharge. The SAW effects on the stream water temperature were observed with temperature increase by $2.1{\sim}5.8^{\circ}C$ in the range of 1.0 to 5.5 km downstream. Temperature effect was the greatest in the hot spring wastewater despite of small amount of effluent. The SAW was not only related to temperature but also to the increase of organic matter and nutrients in the connected stream. The industrial wastewater effluent was discharged with high concentration of nitrogen, while the hot spring wastewater was high in both phosphorus and nitrogen. The difference between these cases was due to with and without chemical T-P treatment in the industrial and the hot spring wastewater, respectively. The chlorophyll-a content of the attached algae was high at the outlet of SAW and the downstream reach, mostly in eutrophic level. These ecological results were presumably due to the high water temperature and phosphorus concentration in the stream brought by the thermal effluents of SAW. These results suggest that high temperature of the SAW needs to be emphasized when evaluating its effects on the stream water quality (water temperature, fertility) through a systematized spatial and temporal investigation.

Origin and Hydrochemical Characteristics of Natural Carbonated Water at Seoqwipo, Jeju Island (제주도 서귀포지역 천연탄산수의 기원과 수리화학특성)

  • Jeong, Chan Ho;Lee, Yong Cheon;Lee, Yu Jin;Choi, Hyeon Young;Koh, Gi Won;Moon, Duk Chul;Jung, Cha Youn;Jo, Si Beom
    • The Journal of Engineering Geology
    • /
    • v.26 no.4
    • /
    • pp.515-529
    • /
    • 2016
  • In this study, geochemical composition, CFCs (Chlorofluorocarbons), ${\delta}^{18}O$, ${\delta}D$, ${\delta}^{13}C$ isotopes and noble gases isotopes (He, Ne) were analyzed to determine their recharge age, source of $CO_2$ gas and noble gases of carbonated hot spring water and carbonated-water samples collected in the Seoqwipo of the Jeju. The pH of the carbonated waters ranges from 6.21 to 6.84, and the high electrical conductivity range ($1,928{\sim}4,720{\mu}S/cm$). Their chemical composition is classified as $Mg(Ca,\;Na)-HCO_3$ and $Na(Ca,\;Mg)-HCO_3$ types. As a result of the calculation of groundwater age using CFCs concentrations as an environmental tracer, the carbonated water and groundwater were estimated to be about 47.5~57.2 years and about 30.3~49.5 years, respectively. The ${\delta}^{13}C$ values of carbonated water range from -1.77 to -7.27‰, and are plotted on thr deep-seated field or the mixing field of the deep-seated and inorganic origin. Noble gases isotopic ($^3He/^4He$, $^4He/^{20}Ne$) ratio shows that helium gas of carbonated hot waters comes from deep-seated magma origin.

Evaluation of Coastal Urban Flood Warning Alarm Rule Using Real Hydrologic Monitoring Observation (실 수문관측을 통한 해안도시홍수 경보발령기준안 검정)

  • Shin, Hyun-Suk;Kang, Doo-Kee;Kim, Hong-Tae;Song, Young-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.336-340
    • /
    • 2007
  • 국내 산업 및 기능적 측면에서 중추역할을 수행하고 있는 부산 울산 인천 등 전체 도시의 40%를 이루고 있는 해안도시들이 하천범람과 같은 홍수피해, 해일피해 등에 대한 체계적인 대비가 전무한 실정으로서 본 연구는 모형화 기법을 이용하여 해안도시홍수 경보발령 기준안을 도출하고 이를 실 수문관측 자료를 이용한 검정을 통해 경보발령 기준안의 문제점을 파악하여 그 개선방향을 제시하였다. 대상유역은 대표적 해안도시하천의 특성을 지니고 있는 부산시 온천천유역으로 강우-수위 관측 모니터링 시스템을 구축, 운영을 통해 10분 간격 강우 및 수위 자료를 구축하였으며, 수위 자료는 수위 유량 관계곡선을 이용하여 유량으로 환산하였다. 미계측 상태에서의 수리 수문 모형화를 통해 도출된 경보발령기준안에 대한 평가 및 문제점 도출을 위해 본 연구는 유역내 실시간 수문관측을 통해 얻은 강우 및 유출 특성 자료를 이용하였다. 대상 유역내 경보발령 지점인 세병교 지점의 20분 누가기준 경보발령 기준우량은 한계수위 $H_{c1},\;H_{c2},\;H_{c4}$인 경우 각각 4mm, 5mm, 6mm로서 20개월 동안 이러한 기준을 이용하여 관측된 강우사상 중 경보발령 기준안의 평가가 가능한 26개의 강우사상을 분류할 수 있었다. 그 결과 약 60%의 강우사상(case_1)이 성공한 경보발령 기준우량 임을 관측할 수 있었으며 이러한 발생강우에 대해 $20{\sim}150$분의 대피여유시간을 확보할 수 있었다. 그러나. 경보발령에 실패한 40%의 강우사상은 발생 강우의 총강우량이 대체적으로 적은 경우 및 지속기간 동안 경보발령기준에 준하는 강우를 발생하였으나 수위에 영향이 미비하여 한계수위에 도달하지 못한 경우(case_2), 20분 누가강우는 기준에 도달하지 않았으나 강우 지속시간이 길어 이미 선행강우로 인해 경보발령 이전에 한계수위를 넘어서는 경우(case_3)로서 분석되었다. 이러한 실패한 경보발령의 경우에 대한 원인분석 결과, 기존의 모형화를 통해 고려되지 못하였던 해안도시 홍수의 특성 중 총강우량에 대한 고려, 선행강우 여부 및 강우 지속시간, 지속시간 내 강우집중도 그리고 선정지점 내 조위의 영향과 유역내 합류식 하수관거 시스템의 영향 등 자연유역과는 다른 다소 복잡한 요소를 고려한 해안도시홍수 경보발령 기준에 대한 개선이 필요함을 확인할 수 있었다.

  • PDF

Theory of self-cultivation for the Unity of Heaven and Man, Mind and Nature in the Doctrine of the Mean (『중용(中庸)』의 천인심성합일(天人心性合一) 수양론(修養論))

  • Seo, Eun-Sook
    • (The)Study of the Eastern Classic
    • /
    • no.35
    • /
    • pp.243-274
    • /
    • 2009
  • This paper attempts to explore the theory of self-cultivation(修養論) for the Unity of Heaven and Man, Mind and Nature(天人心性合一) in the Doctrine of the Mean(中庸). In the unity of heaven and Man, the meaning of the way of Heaven are doctrine of the Mean, sincerity, Nature, Sage, five ways forward, mind of the way, and the meaning of the way of man are thinking to be Cheng(誠之), secularity, the way, education, three methods of excelling, the way of man. The way of Heaven(天道) is the principle of the Universe and give the original Nature to Mankind. The way of Man(人道) is what man should do to accomplish the way of Heaven, and in that process, the unity of Heaven and Man accomplished. The unity of the mand and nature explained by the concept of mind's equilibrium-harmony. When the emotion arise rightly by rectifying mind, the mind unify with the original nature. After the unity of Heaven and Man and the unity of mind and nature, the whole world can governed by nine guidelines(九經) on the base of self-cultivation. There are several methods to get the unity of Heaven and Man and the unity of mind and nature. These are represented by the preserving mind and extending knowledge. In that methods, right timing by watchful when alone, loyalty-sympathetic understanding, selecting Goodness and holding on to it firmly, and fulfilling the mind's equilibrium-harmony

Thermal and Uplift Histories of the Jurassic Granite Batholith in Southern Jeonju: Fission-track Thermochronological Analyses (전주 남부지역 쥬라기 화강암질 저반체의 지열사와 융기사: 피션트랙 열연대학적 해석)

  • Shin, Seong-Cheon
    • Economic and Environmental Geology
    • /
    • v.49 no.5
    • /
    • pp.389-410
    • /
    • 2016
  • Wide ranges of fission-track (FT) ages were obtained from the Jurassic granite batholith in Jeonju-Gimje-Jeongeup area, southwestern Okcheon Belt: sphene=158~70 Ma; zircon=127~71 Ma; apatite=72~46 Ma. Thermochronological analyses based on undisturbed primary cooling and reset or partially-reduced FT ages, and some track-length data reveal complicated thermal histories of the granite. The overall cooling of the batholith is characterized by a relatively rapid earlier-cooling (${\sim}20^{\circ}/Ma$) to $300^{\circ}C$ isotherm since its crystallization and a very slow later-cooling ($2.0{\sim}1.5^{\circ}/Ma$) through the $300^{\circ}C-200^{\circ}C-100^{\circ}C$ isotherms to the present surface temperature. It is indicated that the large part of Jurassic granitic body experienced different level of elevated temperatures at least above $170^{\circ}C$ (maximum>$330^{\circ}C$) by a series of igneous activities in late Cretaceous. Consistent FT zircon ages from duplicate measurements for two sites of later igneous bodies define their formation ages: e.g., quartz porphyry=$73{\pm}3Ma$; diorite=$73{\pm}2Ma$; rhyolite=$72{\pm}3Ma$; feldspar porphyry=$78{\pm}4Ma$ (total weighted average=$73{\pm}3Ma$). Intrusions of these later igneous bodies and pegmatitic dyke swarms might play important roles in later thermal rise over the study area including hot-spring districts (e.g., Hwasim, Jukrim, Mogyokri, Hoebong etc.). On the basis of an assumption that the latercooling of granite batholith was essentially controlled by the denudation of overlying crust, the uplift since early Cretaceous was very slow with a mean rate of ~0.05 mm/year (i.e., ~50 m/Ma). Estimates of total uplifts since 100 Ma, 70 Ma and 40 Ma to present-day are ~5 km, ~3.5 km and ~2 km, respectively. The consistent values of total uplifts from different locations may suggest a regional plateau uplift with a uniform rate over the whole granitic body.

Effects of Thermal Wastewater Effluent and Hydrogen Ion Potential (pH) on Water Quality and Periphyton Biomass in a Small Stream (Buso) of Pocheon Area, Korea (포천지역 계류 (부소천)의 수질과 부착조류 생물량에 온배수와 수소이온농도 (pH) 영향)

  • Jeon, Gyeonghye;Eum, Hyun Soo;Jung, Jinho;Hwang, Soon-Jin;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.1
    • /
    • pp.96-115
    • /
    • 2017
  • Understanding effects of thermal pollution and acidification has long been a concern of aquatic ecologists, but it remains largely unknown in Korea. This study was performed to elucidate the effects of thermal wastewater effluent (TWE) and acid rain on water quality and attached algae in a small mountain stream, the Buso Stream, a tributary located in the Hantan River basin. A total of five study sites were selected in the upstream area including the inflowing point of hot-spring wastewater (HSW), one upstream site (BSU), and three sites below thermal effluent merged into the stream (1 m, 10 m and 300 m for BSD1, BSD2, and BSD3, respectively). Field surveys and laboratory analyses were carried out every month from December 2015 to September 2016. Water temperature ranged $1.7{\sim}28.8^{\circ}C$ with a mean of $15.0^{\circ}C$ among all sites. Due to the effect of thermal effluent, water temperature at HSW site was sustained at high level during the study period from $17.5^{\circ}C$ (January) to $28.8^{\circ}C$ (September) with a mean of $24.2{\pm}3.7^{\circ}C$, which was significantly higher than other sites. Thermal wastewater effluent also brought in high concentration of nutrients(N, P). The effect of TWE was particularly apparent during dry season and low temperature period (December~March). Temperature effect of TWE did not last toward downstream, while nutrient effect seemed to maintain in longer distance. pH ranged 5.1~8.4 with a mean of 6.9 among all sites during the study period. The pH decrease was attributed to seasonal acid rain and snow fall, and their effects was identified by acidophilic diatoms dominated mainly by Eunotia pectinalis and Tabellaria flocculosa during March and August. These findings indicated that water quality and periphyton assemblages in the upstream region of Buso Stream were affected by thermal pollution, eutrophication, and acidification, and their confounding effects were seasonally variable.

Variations of Temperature, Chemical Component and Helium Gas of Geothermal Water by Earthquake Events in Pohang Area (포항 지열수의 지진에 의한 수온, 화학성분 및 헬륨가스의 변화)

  • Lee, Yong Cheon;Jeong, Chan Ho;Lee, Yu Jin;Kim, Young-Seog;Kang, Tae-Seob
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.647-658
    • /
    • 2021
  • In this study, the change of temperature, chemical composition, and helium gas of thermal water in Pohang area was observed from January 2018 to June 2019 in order to interpret the relationship with earthquake events. During observation period earthquakes above M 2.0 within 100 km in a radius from a geothermal well occurred 58 including two earthquake events with a magnitude of 3.0~3.9 and two earthquake events with a magnitude of 4.0~4.9. We introduce a q-factor and earthquake effectiveness (ε) to express the influence of each earthquake as magnitude and distance factors. The geothermal well of 715 m deep was developed in the Bulguksa biotite granite, and the water temperature was observed in the variation from 51.8 to 56.3℃ during monitoring period. At M 4.1 and M 4.6 earthquake events, the increase of geothermal water temperature (𝜟T 2.6~4.5℃) was recorded, and slight change in specific ionic components such as SO4 and Cl, and of chemical types on the Piper diagram were observed. In the 3He/4He vs 4He/20Ne diagram, the original mixing ratio of helium isotope before and after the magnitude 4.1 earthquake was slightly changed from 83.0% to 83.2% of crust-origin 4He, and the from 16.3% to 16.7% of mantle-origin 3He. Hot-cold water mixing ratio before and after earthquakes by using the quartz and chalcedony solubility curves of the silica-enthalpy mixing model was calculated to interpret the temperature change of geothermal water. The model calculation shows the increase of 6.93~7.72% and 1.65~4.94% of hot water ratio at E1 and E2 earthquakes, respectively. Conclusively, the magnitude of earthquake for observable change in the temperature and helium isotope of thermal water is of 4.1 or higher and q-factor value of 30.0 or higher in the study site.