• Title/Summary/Keyword: 온도 보상

Search Result 417, Processing Time 0.03 seconds

Labor Market Performance of the Science and Engineering Graduates and Its Recent Changes in Korea (과학기술 인력의 노동시장 성과 및 근래의 변화)

  • Ryoo, Jaewoo
    • Journal of Labour Economics
    • /
    • v.27 no.1
    • /
    • pp.107-134
    • /
    • 2004
  • This paper attempts to find out the economic roots of the increasing tendency not to choose the science and engineering (S&E) fields in the colleges. The analysis shows that the relative economic position of the S&E graduates measured in terms of employment quality is not significantly different from that of the non-S&E graduates. But the S&E graduates earn relatively low wage and self-employment income. Furthermore, the relative income of the top 5% bracket of the S&E graduates has been declining in the recent five years. The paper concludes that low relative income of the average S&E graduates as well as the increasingly lower relative income of the most able S&E personnel, coupled with the increasing compensating differential required for the S&E jobs, is the main reason for the 'avoidance' phenomenon of the S&E fields.

  • PDF

The Design of the Amplitude and Phase Control Circuit for the Error Sensor Loop in Feedforward Linearizer System (Feedforward 선형화기 시스템의 오차 추출 루프를 위한 크기와 위상 제어 회로의 설계)

  • Nam, Sang-Dae;Park, Ung-Hui;Jang, Ik-Su;Yun, Sang-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.2
    • /
    • pp.91-97
    • /
    • 2000
  • Tn this paper, a novel control circuit applicable to the error sensor loop block in the feedforward linearizer system is proposed. The proposed control circuit is applied to the error sensor loop block, where in the 11dB power range, it operates stably, and makes main carrier signals to be eliminated more than 40dB below 3$\^$rd/ order IM level. In the operating point, the amplitude control error is 0.05∼0.12dB, and the phase control error is smaller than 0.02。. It is verified theoretically as well as experimentally that the control circuit can precisely compensate the variation of nonlinear characteristics in a high power amplifier, due to the variations of input power, operating temperature, humidity and the other system environments.

  • PDF

A 13-Gbps Low-swing Low-power Near-ground Signaling Transceiver (13-Gbps 저스윙 저전력 니어-그라운드 시그널링 트랜시버)

  • Ku, Jahyun;Bae, Bongho;Kim, Jongsun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.49-58
    • /
    • 2014
  • A low-swing differential near-ground signaling (NGS) transceiver for low-power high-speed mobile I/O interface is presented. The proposed transmitter adopts an on-chip regulated programmable-swing voltage-mode driver and a pre-driver with asymmetric rising/falling time. The proposed receiver utilizes a new multiple gain-path differential amplifier with feed-forward capacitors that boost high-frequency gain. Also, the receiver incorporates a new adaptive bias generator to compensate the input common-mode variation due to the variable output swing of the transmitter and to minimize the current mismatch of the receiver's input stage amplifier. The use of the new simple and effective impedance matching techniques applied in the transmitter and receiver results in good signal integrity and high power efficiency. The proposed transceiver designed in a 65-nm CMOS technology achieves a data rate of 13 Gbps/channel and 0.3 pJ/bit (= 0.3 mW/Gbps) high power efficiency over a 10 cm FR4 printed circuit board.

Fabrication and Characteristics of Photoconductive Amorphous Silicon Film for Facsimile (팩시밀리용 비정질 실리콘 광도전막의 제작 및 특성)

  • Kim, Jeong-Seob;Oh, Sang-Kwang;Kim, Ki-Wan;Lee, Wu-Il
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.6
    • /
    • pp.48-56
    • /
    • 1989
  • Contact-type linear image sensors for facsimile have been fabricated by means of rf glow discharge decomposition method of silane. The dependence of their electrical and optical properties on rf power, $SiH_4$ flow rate, ambient gas pressure, $H_2SiH_4$ ratio and substrate temperature are described. The a-Si:H monolayer demonstriated photosensitivity of 0.85 and $I_{ph}/I_d$ ratio of 100 unger 100 lux illumination. However, this monolayer has relatively high dark current due to carrier injection from both electrodes, resulting in low $I_{ph}/I_{dd}$ ratio. To suppress the dark current we have fabricated $SiO_2/i-a-Si:H/p-a-Si:H:B$ multilayer film with blocking structure. The photocurrent of this multilayer sensor with 6 V bias became saturated ar about 20nA under 10 lux illumination, while the dark current was less than 0.2 nA. Moreover, the spectral sensitivity of the multilayer film was enhanced for short wavelength visible region, compared with that of the a-Si:H monolayer. These results show that the fabricated photocon-ductive film can be used as the linear image sensor of the facsimile.

  • PDF

Temperature Dependency of Non-dispersive Infrared Carbon Dioxide Gas Sensor by using Infrared Sensor for Compensation (보상용 적외선 센서를 사용한 비분산 적외선 이산화탄소 센서의 온도특성)

  • Yi, SeungHwan
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.124-130
    • /
    • 2016
  • NDIR $CO_2$ gas sensor was built with ASIC implemented thermopile sensor which included temperature sensor and unique elliptical waveguide structures in this paper. The temperature dependency of dual infrared sensor module ($CO_2$ and reference IR sensors) has been characterized and its output voltage characteristics according to the temperature and gas concentration were proposed for the first time. NDIR $CO_2$ gas and reference IR sensors showed linear output voltages according to the variation of ambient temperatures from 243 K to 333 K and their slopes were 14.2 mV/K and 8.8 mV/K, respectively. The output voltages of temperature sensor also presented a linear dependency according to the ambient temperature and could be described with V(T)=-3.191+0.0148T(V). The output voltage ratio between $CO_2$ and reference IR sensors revealed irrelevant to the changes of ambient temperatures and gave a constant value around 1.6255 with standard deviation 0.008 at 0 ppm. The output voltage of $CO_2$ gas sensor at zero ppm $CO_2$ gas consisted of two components; one is caused by the HPB (half pass-band) of IR filter and the other is attributed to the part of $CO_2$ absorption wavelength. The characteristics of output voltages of $CO_2$ gas sensor could be accurately modeled with three parameters which are dependent upon the ambient temperatures and represented small average error less than 1.5% with 5% standard deviation.

Long-term Durability Characteristics of Fly ash Concrete Containing Lightly Burnt MgO Powder (저온 소성한 MgO 분말을 함유한 플라이애시 콘크리트의 장기재령에서의 내구특성)

  • Jang, Bong-Seok;Choi, Seul-Woo;Lee, Kwang-Myong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.909-916
    • /
    • 2013
  • Concrete containing lightly burnt MgO has long term expansibility. It also could compensate for the thermal shrinkage of mass concrete, because the hydration of MgO proceeds at a slow pace to long-term age. Thus, lightly burnt MgO has been applied to the construction of mass concrete such as dams. Recently, the expansion characteristics of MgO concrete with fly ash that could be applied to mass concrete for the reduction of hydration heat have been studied and however, limited studies on its durability. This study investigates the long-term durability characteristics of fly ash concrete with lightly burnt MgO. The durability tests on carbonation, freezing-thawing, diffusion of chloride, and resistance to sulfate attack were carried out for MgO concrete with curing for 360 days in submerged condition with different temperature of 20 and $50^{\circ}C$. The results reveal that MgO concrete shows a greater resistance of carbonation, diffusion of chloride, and resistance to sulfate attack. On the other hand the resistance of freezing-thawing was little influenced by MgO powder.

Fast Handoff through Minimizing L2 Delay in Next Generation Mobile System (차세대 이동통신 시스템에서 L2 지연 감소를 통한 빠른 핸드오프)

  • Choi Hye-Eun;Kim Namgi;Yoon Hyunsoo
    • The KIPS Transactions:PartC
    • /
    • v.11C no.7 s.96
    • /
    • pp.1023-1032
    • /
    • 2004
  • It is generally known that handoff delay degrades the QoS by packet drop, packet delay and jitter. Moreover. handoff highly effects on QoS in beyond 3G system because not only micro cells for achieving high capacity and fast moving nodes induce the frequent handoff but also hard handoff must be carried out in OFDM system. Therefore, study on a handoff algorithm for guaranteeing QoS is required. Related works on handoff for beyond 3G system mainly focused on reducing the L3 handoff delay or packet loss. That is, these schemes try to compensate L2 delay rather directly eliminate it. However, remained 1.2 delay degrades QoS, especially delay-sensitive realtime traffic. Therefore, we proposed the seamless handoff algorithmwhich can minimize the L2 handoff delay.

A Study on the Corrosion Inhibitor Test Method in Acqueous Solutions (부식억제제의 부식억제능 측정법에 대한 연구)

  • 원덕수;김영근;이성민;고영태;박용수
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.45-45
    • /
    • 1999
  • 일반 구조용 탄소강은 수용액 중에 노출될 때 부식에 의한 손상을 받기 쉽다. 부식의 양지를 위한 방법으로 사용 매체 중에 부식억제제를 첨가하여 탄소강의 부식속도를 낮추는 방법은 흔히 사용되는 방법이다. 부식억제제는 부식억제의 원리에 따라 양극부식억제제, 음극부식억제제 그리 고 이들의 혼합부삭억 세제 둥 여러 종류가 목적에 따라 사용되고 있다. 일반적으로 부식억제제의 성능 평가에는 무게감량볍, 표면분석법, 분극거동측정, 부석전위, 선 형분극법에 의한 부식속도 측정 등 다양한 방법이 시도되고 있다. 이 중에서 전기화학적 평가볍 은 부삭억제제의 작용 기구 규명 등을 위하여 많이 사용되고 있다. 한편 제품의 개발 단계에서 실질적인 평가법으로 갈리 사용하고 있는 방법은 무게 감량법인데 이 방법은 전면부식에 의한 금 속 손실량을 측정하여 부식억제능을 측정하는 방법이다. 그러냐 실제로 부삭억제제가 사용되고 있는 환경에서의 부식양상을 판찰하여보면 전면부식에 의한 손상보다는 국부부식에 의한 손상이 보다 치명적언 경우를 종종 목격할 수 있다. 이러한 관점에서 가존의 무게감량법은 한계가 있다. 따라서 본 연구에서는 이러한 국부부식을 보다 효과적으로 평가하기 위해 새로운 시험법을 도 입 상용 부식억제제의 종류별로 비교하였다. 부식억제제로는 수용액 중의 부식억제제로 널리 사용되고 있는 Nalco 39L과 본 연구실에서 SK해미칼과 공동 개발한 GH-110 등에 대하여 MCA(Multiple Crevice Assembly)를 이용 틈부식 저항성을 평가하였다. 또한 박막화된 전기저항형 부석속도 측정 센서를 틈부식 형태의 부식측정 에 적용하는 연구를 행하였다. 시험에 사용한 재갚는 천연가스의 감압 온도보상용으로 운전하는 가스히터의 주 구성 재료인 저탄소강을 사용하였으며 열화된 부식억제제 용액으로 사용기간이 서로 다른 수용액들에 대하여 평가 방법을 적용하여 비교하였다 다양한 부식억 제 제 수용액을 비교한 결과 MCA(Multiple Crevice Assembly)를 이용한 틈부식 억제능 시험은 실제 현장 사험 결과와 어느 정도 일치하는 결과를 보였다. 새로운 틈부식 저항성 측정법으로 시도한 철박막을 이용 틈부식 측정법은 육안 검사를 실시하지 않고도 틈부식의 전행 여부를 확인할 수 있는 가능성을 확인하였다.

  • PDF

Realization of a 7.7~8.5GHz 10 W Solid-State Power Amplifier (7.7~8.5 GHz 10 W 반도체 전력 증폭기의 구현에 관한 연구)

  • 박효달;김용구
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.12
    • /
    • pp.2489-2497
    • /
    • 1994
  • This paper presents the development of a 10 W solid-state hybrid power amplifier(SSPA). operating over $7.7\sim8.5GHz$. The fabrication and measurement of this amplifier are performed with 3 sections, such as the front one for high gain, the middle one for driving, and high power one, to minimize the risk of failure and to increase the easiness of development. and then the final amplifier is realized by connecting 3 sections above mentioned, DC bias circuit, and temperature compensation circuit on one housing. Total small signal gain obtained is about $45\pm1dB$, the input and output return losses are 25 and 27 dB respectively. The output power measured at 1 dB gain compression point for 3 frequencies at 7.7, 8.1, and 8.5 GHz are $39.8\sim40.4dBm$, which is about 10 W. and the 3rd-order harmonic powers of 2 tones test are 13.34 dBc at output power 37.5 dBm. These obtained results satisfies the initially required specification. and the realized SSPA can be installed as a subsystem of the microwave transponder for telecommunication.

  • PDF

Development of a Direct-Connected Supersonic Combustor Test Facility (직결형 초음속 연소기 시험 설비 개발)

  • Yang, Inyoung;Lee, Kyung-jae;Lee, Yang-ji;Kim, Hyung-Mo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.290-293
    • /
    • 2017
  • A direct-connected, continuous type combustion test facility was developed to test a supersonic combustor model used in scramjet engines. The facility requirements were determined by assuming the flight speed of Mach 5, yielding the combustor inlet flow speed of Mach 2. Also the cross-section of the supersonic combustor under test was assumed as $32mm{\times}70mm$. As a result, the facility was designed to have the flow total pressure of 548 kPaA, total temperature of 1,320 K, and flow rate of 0.776 kg/s. The facility consists of a turbo type air compressor, electric air heater, vitiation air heater and a two dimensional facility nozzle to accelerate the flow to Mach 2. Also, an oxygen supply system was added to compensate the vitiation. The exhaust de-pressurization system is not added. Designed pressure, temperature, and flow rate were verified through the test operation of the facility.

  • PDF