• Title/Summary/Keyword: 온도 강하

Search Result 352, Processing Time 0.029 seconds

Study on improvement of on-state voltage drop characteristics According to Variation of JFET region of IGBT structure (IGBT 구조의 JFET영역 변화에 따른 온-상태 전압강하 특성 향상을 위한 연구)

  • Ahn, Byoung-Sup;Kang, Ey-Goo
    • Journal of IKEEE
    • /
    • v.22 no.2
    • /
    • pp.339-343
    • /
    • 2018
  • Power semiconductors are semiconductors capable of controlling power over 1W and are mainly used as switches. This power semiconductor device has been developed with the goal of reducing power consumption and high breakdown voltage. This research was analyzed electrical characteristics of IGBT(Insulated Gate Biopolar Transistor) according to diffusion length of JFET region. The Diffusion length of JFET region was controlled by temperature and time using T-CAD simulator. As a result of experiments, we could obtain 1.14V low on state voltage drop by fixing 1440V breakdown voltage.

파일롯 투과증발장치에서 투과액의 상전이외 체류액의 온도강하에 관한 연구

  • 송규민;홍원희
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.90-91
    • /
    • 1996
  • 투과증발은 일반 막공정과 달리 투과물의 상전이와 이로 인한 체류액의 온도강하가 존재하기 때문에 열전달현상을 간과할 수 없다. 즉 막을 통한 열전달이 다른 막공정에 비해 현저하게 차이가 난다는 것이다. 이러한 현상은 모듈의 길이가 짧거나 모듈을 항온조에 담가 수행하는 실험실 규모의 투과증발조업에서는 거의 발견되지 않는다. 그러나 투과증발장치가 커져 모듈의 항온유지가 블가능하고 사용되는 막도 상업화되어 투과속도가 비교적 큰 것을 사용하는 파일롯 규모의 실험에서는 쉽게 나타나는 현상이다. Rautenbach등이 셀룰로오즈 아세테이트 막을 이용한 물의 투과증발 실험에서 막간 온도강하가 5~12 K정도 일어났음을 보고한 바 있었다. 이때 온도강하는 조업조건에 따라 달라졌으며 유속이 낮을 수록 증가함을 보였다. 본 연구에서는 투과증발이 일어나는 모듈내에서 열전달현상을 열공급비를 정의하여 해석하였으며, 상전이 현상이 막분리효율에 끼치는 영향을 설명하였다.

  • PDF

A study on the temperature drop rate for a military product test & evaluation in the mountains (군수품 환경시험을 위한 남한 산악 지역 고도에 따른 온도강하율 산출 연구)

  • Kim, Youngrae;Yun, Jae-Hyeong;Na, Jae-Hyun;Kim, Jang-Eun;Kim, Si-Ok;Kim, DongGil;Hong, YeonWoong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.5
    • /
    • pp.1145-1152
    • /
    • 2017
  • Environmental tests are used to verify an equipment that can withstand the rigors of harsh environments. In general, military products have lots of experiences with extreme environment compared to commercial products. Therefore, the military products used in mountains require a tailoring process about temperature drop for the environmental test. The International Organization for Standardization publishes that the coefficient of temperature drop is $-6.5^{\circ}C/1000m$ from all around the world. However, there is no the criteria in the South Korea. In this paper, we calculate the coefficient of temperature drop. Also, an equation used as a tailoring process for a low temperature test of the products has been suggested.

Non-isothermal Effect on the Flow Behavior of Polymer Melts in a Coextrusion Die (고분자의 Coextrusion에서 유동에 대한 비등온 효과)

  • 정인재
    • The Korean Journal of Rheology
    • /
    • v.6 no.2
    • /
    • pp.129-138
    • /
    • 1994
  • 공압출되는 sheet die에서 고분자 물질의 비등온 유동유동을 수치모사하였다. 유변학 적 식으로 power-law model을 사용하였고, 격자생성법을 이용한 유한차분법을 사용하였다. 수치계산을 통해 수축채널에서의 온도 분포를 구해보고 점도가 채널에서의 온도 분포를 구 해 보고 점도가 채널에서의 압력강하 및 신장속도에 미치는 영향을 알아보았다. 압력강하는 외부 유체의 점도 및 heat dissipation의 영향을 크게 받았다. 신장속도는 외부 유체의 점도 가 증가함에 따라 커진 반면 내부 유체의 점도가 증가함에 따라 커진반면, 내부 유체의 점 도증가에 따라 감소하였고, heat dissipation에 의해 증가하였다.

  • PDF

Characteristics of Cryogenic Cascade Refrigeration Cycle for Liquefaction of Natural Gas with the Pressure Drop of Heat Exchanger (LNG 열교환기의 압력강하에 따른 천연가스 액화용 초저온 캐스케이드 냉동사이클 특성)

  • Yoon, Jung-In;Choi, Kwang-Hwan;Son, Chang-Hyo;Kwag, Jin-Woo;Baek, Seung-Moon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.756-761
    • /
    • 2012
  • Natural gas is converted in to LNG by chilling and liquefying the gas to the temperature of $-162^{\circ}C$, when liquefied, the volume of natural gas is reduced to 1/600 of its standard volume. This gives LNG the advantage in transportation. In this study, the effects of the pressure drop of refrigerant and natural gas in the LNG heat exchanger of cryogenic cascade refrigeration cycle were investigated and then the design criteria for the pressure drop of refrigerant and natural gas of the LNG heat exchanger were proposed. The pressure drop of the cascade liquefaction cycle was investigated and simulated using HYSYS software. The simulation results showed that the pressure drop in the LNG heat exchanger is set to 50 kPa considering the increase in the compressor work and COP of cryogenic cascade liquefaction cycle.

Modeling of Medium Temperature Drops of the Elevated-bench Hydroponics for Strawberry Cultivation during Low Temperature Season (저온기 딸기 고설 수경재배시 온실기온에 따른 배지내 온도강하 모델 개발)

  • Park, Jae-Wan;Ha, Yu-Shin;Kim, Ki-Dong;Park, Dae-Heum;Lee, Ki-Myung;Jun, Ha-Joon;Kwon, Soon-Gu;Choi, Won-Sik;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • A study on modeling of medium temperature drops of the elevated-bench hydroponic system for strawberry cultivation during low temperature season was conducted. Four different conditions were used for the experiment. These consisted of two kinds of bed types (plant, V), four kinds of medium (rice, perlite, rice hulls80% and peatmoss20%, perlite80% and peatmoss20%), two kinds of mulched bed (mulched, non mulched) and four kinds of greenhouse air temperature (l.5, 3.2, 5.0, $6.7^{\circ}C$), and the results were summarized as follows: Temperature drop of medium in the V-bed was slower than that in the plant bed, showing better insulation effect of V-bed. Temperature drop of medium with mulching on the top of the bed was slower than the case without mulching, as a result, the beneficial effect of temperature drop was appeared in mulched bed. Linear regression of the temperature descent rate and the temperature difference between medium and air showed significant correlation. The regression equation for the Pearlite80% and Peatmoss20% in the V-bed was f(x) = -0.2656 + 0.1345x at the $R^2$ of 0.9269. Using the model, the temperature drop during night can be predicted for the various media at the different depths.

Investigation about the Decrease Efficiency of Thermal Discharge Temperature at Mixing Basin of Power Plant using 3-D CFD (3차원 수치모의에 의한 발전소 배수로 혼합지에서의 온배수 수온저감 효과에 대한 고찰)

  • Park, Byong-Jun;Lee, Sang-Hwa;Park, Ji-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.593-593
    • /
    • 2012
  • 본 연구는 화력 및 원자력 발전소로 취입된 냉각수(circulating and essential service water)가 복수기로부터 온배수 형태의 개수로 흐름으로 표층배수 될 경우 수온을 저감시키기 위해 주입하는 희석수(by-pass cooling water)와의 혼합효과의 효율성을 증대시키고, 불리한 수리현상을 야기하지 않으며, 경제적인 배수로 구조물을 고찰하기 위한 목적으로 시도되었다. 배수로 구조물 내 온배수와 희석수가 혼합되는 구간을 혼합지(mixing basin)라 하는데, 본 과업에서는 ${\bigcirc}{\bigcirc}$발전소의 배수로 구간 중 혼합지를 대상으로 FLOW-3D$^{(R)}$를 이용한 3차원 수치모형을 구축하고, 총 9개에 해당하는 각 대안별 현상을 분석하고 비교하였다. 각 대안들의 차이점은 배수로에 설치되는 보조구조물들의 형상과 배열 등이며, 복수기로부터 나오는 배출수의 수온은 $42^{\circ}C$, 희석수는 $35^{\circ}C$이고, 본 과업의 주요 관심대상 물리량은 유속과 온도이다. 배수로에 아무런 보조 구조물이 없는 형태인 기본 계획안을 검토한 결과, 평균 $3.31^{\circ}C$의 수온강하가 이루어졌으나, 우안 쪽으로 강한 흐름이 발생하여 수온의 좌우편차가 $4.61^{\circ}C$ 가량 발생하는 것으로 나타났다. 기본 계획안의 검토결과를 보완하기 위한 대안으로 연직 흐름의 소산을 위해 고안된 잠형 소파블록(baffle block) 설치안은 평균 $3.06^{\circ}C$의 수온강하가 이루어지고 $4.44^{\circ}C$의 수온 좌우편차가 발생했다. 지그재그(zigzag) 형태의 흐름을 만들어 혼합효과를 올리기 위한 미로형 수제(labyrinth groin) 설치안은 평균 $5.33^{\circ}C$의 수온강하가 이루어지고, $1.43^{\circ}C$의 수온 좌우편차를 보여줘 검토했던 대안들 중 가장 좋은 결과를 보여주었다. V자 배열 소파블럭(deformed block) 설치안은 연직 및 수평방향의 소산을 기대했으나 평균 $3.00^{\circ}C$의 수온 강하와 $4.41^{\circ}C$의 수온 좌우편차를 나타냈다. 벤츄리(Venturi) 형태의 흐름을 발생시키기 위한 병목형(bottleneck) 수로안은 평균 $3.18^{\circ}C$의 수온강하와 $3.94^{\circ}C$의 수온 좌우편차, 흐름의 소산과 흐름방향을 변화시키기 위한 와형 수제(swirl groin) 설치안은 평균 $2.24^{\circ}C$의 수온강하와 $1.48^{\circ}C$의 수온좌우편차, 우안 흐름을 지연시키기 위한 물방석(water cushion) 수로안은 평균 $3.03^{\circ}C$의 수온강하와 $4.50^{\circ}C$의 수온 좌우편차, 우안의 흐름을 좌안으로 보내기 위한 분사형(injector) 수로안은 평균 $3.13^{\circ}C$의 수온강하와 $4.45^{\circ}C$의 수온 좌우편차, 우안의 흐름을 막기 위한 외팔형 수제(cantilever groin) 설치안은 평균 $3.11^{\circ}C$의 수온강하와 $3.02^{\circ}C$의 수온 좌우편차가 발생하는 것으로 나타났다.

  • PDF

Investigation on Temperature Drop during Pressurant Discharging from Pressurant Tank of Liquid Rocket Propulsion System (II) (액체로켓추진시스템의 가압제 탱크에서 가압제 토출시 온도강하율에 대한 연구(II))

  • Chung, Yong-Gahp;Kim, Yong-Wook;Kim, Yoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.3
    • /
    • pp.279-284
    • /
    • 2008
  • Propellant pressurization system in liquid rocket propulsion system plays a role in supplying pressurant gas at a controlled pressure into the ullage space of propellant tanks. The most important design parameter for such propellant pressurization system is the temperature of pressurant gas fed from pressurant tank, which is placed inside of cryogenic propellant tank. Such pressurant is gaseous state, of which density is very sensitive to the temperature of pressurant. Previous investigation dealt with thermal correlation of pressurant and external fluid at room temperature. This study investigates the temperature variation of cryogenic pressurant (GHe) at the time when the pressurant is coming out of pressurant tank, which is submerged in a liquid oxygen, experimentally as well as numerically.

Investigation on Temperature Drop during Pressurant Discharging from Pressurant Tank of Liquid Rocket Propulsion System (II) (액체로켓추진시스템의 가압제 탱크에서 가압제 토출 시 온도강하율에 대한 연구 (II))

  • Chung, Yong-Gahp;Kwon, Oh-Sung;Cho, Nam-Kyung;Han, Sang-Yeop;Cho, In-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.58-64
    • /
    • 2007
  • Propellant pressurization system in liquid rocket propulsion system plays a role supplying pressurant gas at a controlled pressure into the ullage space of propellant tanks. The most important design parameter for such propellant pressurization system is the temperature of pressurant gas fed from pressurant tank, which is placed inside of cryogenic propellant tank. Such pressurant is gaseous state, of which density is very sensitive to the temperature of pressurant. Previous investigation dealt with thermal correlation of pressurant and external fluid at room temperature. This study investigates the temperature variation of cryogenic pressurant (GHe) at the time when the pressurant is coming out of pressurant tank, which is submerged in a liquid oxygen, experimentally as well as numerically.

  • PDF

Cooling Characteristics of HEV Battery with Different Lay-Outs (HEV 배터리의 Lay-Out 변화에 의한 냉각 특성)

  • Jeong, Ju-Hoon;Lee, Dong-Ryul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.743-747
    • /
    • 2012
  • 본 논문에서는 HEV배터리의 Lay-Out 변화의 형상 및 개수와 위치 변화에 따른 냉각 특성에 관하여 연구 하였다. Lay-Out의 형상과 위치 변화에 따른 온도, 압력, 속도를 분석 하였고, 1가지 기본 형상을 기준으로 2가지 형상 변화를 통하여 온도, 압력, 속도를 비교해 보았다. 사각형의 입, 출구의 위치의 개수 추가 했을 때 온도강하가 일어나는 것을 알 수 있었으며, 입구 형상을 원으로 하고 위치변화와 개수를 변화 하였을 때 사각형의 입구 보다 더 좋은 온도강하의 결과를 도출해 낼 수 있었다.

  • PDF