• Title/Summary/Keyword: 온도좌굴

Search Result 56, Processing Time 0.021 seconds

A Study on the Capacity of H-Shape Columns at Elevated Temperatures (온도상승에 따른 H-형강 기둥의 내력에 관한 연구)

  • Koo, Bon-Youl;Jang, Myung-Woong;Kang, Moon-Myung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.1 s.11
    • /
    • pp.87-95
    • /
    • 2004
  • This paper shows the study on the capacity of H-shape column at elevated temperature in fire. The main parameters are temperatures, slenderness ratios and load ratios. The physical properties of steel material at elevated temperatures are according to EC3 Part 1.2. The critical temperature of local buckling at elevated temperatures are lower when the yield strength of the material is higher, and when the ratios of width-thickness of plates are larger. The evaluation capacity of uniformly heated steel cloumns were considered to axial forces, moments of strong axis and weak axis to the LRFD.

  • PDF

The Effects of Welding Length on the Angular Distortion (용접 각변형에 미치는 용접길이의 영향)

  • 박정웅;강재완;정우현
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.232-233
    • /
    • 2004
  • 강구조물 제작 시 용접프로세스에 의해 용접부 근방에 불균일한 온도분포가 발생하여 용접변형이 발생된다. 이러한 용접변형은 좌굴강도와 피로강도를 저하시킬 뿐 아니라 구조물의 크기와 형상을 변화시켜 이를 교정하거나 수정하기 위해 추가작업을 실시해야함으로 생산성을 저하시키는 주요한 요인이 되고 있다. (중략)

  • PDF

Thermal Buckling of Thick Laminated Composite Plates under Uniform Temperature Distribution (균일분포 온도하의 두꺼운 복합 재료 적층판의 열적 좌굴 해석)

  • Lee, Young-Shin;Lee, Yeol-Wha;Yang, Myung-Seog;Park, Bock-Sun;Lee, Jong-Soo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1686-1699
    • /
    • 1993
  • In this paper, the thermal buckling of thick composite angle-ply laminates subject to uniform temperature distribution is studied. For the plates of 4-edges simply supported condition and those of 4-edges clamped condition, the critical buckling temperatue is derived, using tile finite element method based on the shear deformation theory. The effects of lamination angle, layer number, laminate thickness, plate aspect ratio and boundary constraints upon the critical buckling temperature are presented.

Sensitivity of Track Components on the Linear Thermal Buckling (선형온도좌굴에 대한 궤도 구성요소의 민감도)

  • 임남형;강영종;성익현
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.207-212
    • /
    • 2002
  • The actual buckling of the railroad track structure is suspected to be a complex interaction between the vertical, lateral and torsional modes. To make the analysis tractable, however, most studies restrict themselves to either the vertical or the horizontal plane. Based on a comprehensive and realistic three-dimensional track model developed in the previous study, three dimensional buckling analysis of CWR track subjected to temperature load was performed. Using the study on buckling temperature and mode, sensitivity of track components such as tie spacing, ballast resistance, stiffness of pad-fastening system and rail size were investigated.

  • PDF

Investigation on the Temperature Characteristics of CWR for the Climate Change (기후변화에 대비한 장대레일 온도특성 연구)

  • Choi, Jin-Yu;Lee, Gyu-Sei;Bae, Hyun-Ung;Park, Beom-Ho;Lim, Nam-Hyoung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.2
    • /
    • pp.179-185
    • /
    • 2010
  • In order to secure safety for the buckling and fracture of continuous welded rail and improve the efficiency of maintenance work, it is very important that grasp the characteristics of rail temperature. Recently, the maximum air temperature in summer season rises gradually and the minimum air temperature in winter season is decreasing gradually due to the climate change. Therefore, these phenomenon influences in the change amount of yearly rail temperature and can cause change of laying and maintenance temperature. In this study, actual measurement of rail temperature including climatic factors is carried out by constructing the temperature and climate measurement system as realistic as possible. Through the intensive investigation of actual data, it is founded that the existing prediction formulas for rail temperature may be used only in certain climatic conditions (certain combination of climatic factors). It may be more reasonable that the rail temperature considering actual climatic factors in site is predicted on probabilistic approach.

Analysis of stress and distortion that develop during accelerated cooling of plate (가속냉각시 강판에 발생하는 응력 및 변형에 대한 연구)

  • 김호영;김창영;주웅용;장래웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.952-958
    • /
    • 1988
  • To analyze the nonflatness and residual stress in accelerated cooled plate, a numerical analysis model has been developed. Two factors, i.e. temperature and phase transformation, are considered in calculating the stress distribution that develops during cooling. The plastic strain and plate-buckling, which are often shown in accelerated cooled plate, were determined from this stress. Mean temperature in through thickness direction and temperature difference in width direction are considered in the model to simplify the calculation. The temperature and stress distribution changes caused by phase transformation are involved in terms of the effective specific heat and the effective thermal expansion coefficient. With the model, accelerated cooling of 10mm(t) $^{*}$3000mm(w) plate was simulated. The condition of accelerated cooling was .deg. C/sec from just after hot rolling to 500.deg. C. The initial temperature-difference ratio, .DELTA.Tr, in width direction is an important factor in evaluating the stress distribution. When .DELTA.Tr is 0.08, buckling occurs during cooling and 7kgf/m $m^{2}$ of residual stress develops at the edge of plate. To secure the flatness, .DELTA.Tr should be less than 0.07. Small scaled cooling test was conducted to verify the exactness of the model and the results proved the usefulness of this numerical analysis model.l.

Temperature and Loading-Rate Dependence on the Mechanical Behavior of Carbon Nanotubes (탄소나노튜브의 역학적 거동에 관한 온도와 하중부하속도의 의존성)

  • Jeong Byeong-Woo;Lim Jang-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.7 s.250
    • /
    • pp.809-815
    • /
    • 2006
  • The temperature and loading-rate dependence on the mechanical behavior of single-walled carbon nanotubes under axial compression and torsion is examined with classical molecular dynamics simulation. The critical buckling is found to depend on the temperature and loading-rate. The yielding under torsion is also found to depend on the temperature and loading-rate. But it is shown that the compression and torsional stiffness are independent of the varied temperatures and loading-rates.

Parametric Study on Thermal Buckling of CWR Tracks (장대레일궤도의 온도좌굴에 영향을 미치는 매개변수 연구)

  • 최동호;김호배
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.295-302
    • /
    • 2001
  • The lateral stability of curved continuous welded rail (CWR) is studied fur buckling prevention. This study includes the influences of vehicle induced loads on the thermal buckling behavior of straight and curved CWR tracks. quasi-static loads model is assumed to determine the uplift region, which occurs due to the vertical track deformation induced by wheel loads of vehicle. Parametric numerical analyses are performed to calculate the upper and lower critical buckling temperatures of CWR tracks. The parameters include track lateral resistance, track curvature, longitudinal stiffness, tie-ballast friction coefficient, axle load, truck center spacing, and the ratio of lateral to vertical vehicle load. This study provides a guideline for the improvement or stability for dynamic buckling in on tracks.

  • PDF

An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection (내화피복 종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구)

  • Kim, Hae-Soo;Lee, Chy-Hyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.523-532
    • /
    • 2010
  • Concrete-filled square steel tube (CFT) columns have inherently high fire resistance and load-bearing capacity. Nevertheless, it is sometimes necessary to improve their fire resistance using external fire protection. This paper presents the experimental results of the temperature distribution of CFT columns with fire protection. A fire load test was carried out by exposing small-scale specimens to heat in an electric furnace that was especially built for testing loaded columns. The temperature distribution of CFT columns under constant axial loads was determined, as were its significant parameters, such as the types of fire protection and thickness, the thickness of the square CFT, and the fire duration times. The results of this study showed the temperature distribution of each specimen of the electric furnace and the temperature distribution properties of concrete and steel. In addition, the axial displacement and local buckling behavior of CFT columns based on temperature changes was observed.

The Characteristics of Rail Temperature for Track Maintenance (궤도 관리를 위한 레일 온도의 특성)

  • 구봉근;서사범
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.1
    • /
    • pp.19-26
    • /
    • 2000
  • The rail temperature is important to preserve the joint gap for standard length of rail and to determine the installation temperature which has direct influence on the rail buckling and failure in welded part for continuous welded rail(CWR), Therefore, we have measured and investigated various characteristics of rail temperature for each kind of rail. As the results of this, the correlation between the atmosphere temperature and the rail temperature which is commonly used by Korean Railway should be reconsidered. Also, the daily highest '||'&'||' lowest rail temperature was occurred when each temperature is higher and when it's lower. For the light rail, the rail temperature by the sun-light increases quickly and decreases late. But the time where the highest temperature is attained is same. There are some differences between the shade and sunny place about 3.0∼4.0$\^{C}$. The temperature of rail web is almost close to the conversion rail temperature for rail expansion. The wind of 1 m/s has an influence on the rail temperature around 5$\^{C}$.

  • PDF