A Comparison between the Decomposition of Bisphenol A and the Concentration of Hydrogen Peroxide Formed during Ozone/Catalyst Oxidation Process (오존/촉매 산화공정에서 비스페놀 A의 분해와 생성된 과산화수소의 농도 비교)

  • Choi, Jae Won;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.28 no.6
    • /
    • pp.619-625
    • /
    • 2017
  • In this study, the formation of hydroxyl radical and decomposition characteristics of bisphenol A (BPA) was investigated by quantifying hydrogen peroxide formed as a reaction by-product during the formation stage of hydroperoxyl radical. The direct oxidation reaction by ozone only decomposed BPA just like the Criegee mechanism under the condition where radical chain reactions did not occur. Non-selective oxidation reactions occurred under the conditions of pH 6.5 and 9.5 where radical chain reactions do occur, confirming indirectly the formation of hydroxyl radical. The decomposition efficiency of BPA by the added catalysts appeared in the order of $O_3$/PAC ${\geq}$ $O_3/H_2O_2$ > $O_3$/high pH > $O_3$ alone. 0.03~0.08 mM of hydrogen peroxide were continuously measured during the oxidation reactions of ozone/catalyst processes. In the case of $O_3$/high pH process, BPA was completely decomposed in 50 min of the oxidation reaction, but reaction intermediates formed by oxidation reaction were not oxidized sufficiently with 29% of the removal ratio for total organic carbon (TOC, selective oxidation reaction). In the case of $O_3/H_2O_2$ and $O_3$/PAC processes, BPA was completely decomposed in 40 min of the oxidation reaction, and reaction intermediates formed by the oxidation reaction were oxidized with 57% and 66% of removal ratios for TOC, respectively (non-selective oxidation reactions).

The Investigation of General Characteristics for Dry Deposition Velocity of $O_3$ (오존에 대한 건성침적속도의 일반적 특성 고찰)

  • 이화운;김유근;문난경
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.191-193
    • /
    • 2000
  • 오존 등 기체상 오염물질의 식물 표면에 대한 건성침적은 식물의 생물학적 활동에 피해를 줄 수 있으며(Runeckles and Chevone, 1992; Chappelka and Chevone, 1992), 건성침적 현상은 노출된 식물지표 환경의 화학적 특성을 변화시키는 작용으로 관심의 대상이 되고있다(Businger, 1986; Galbally et al., 1986; Chang et al., 1987; Wesely, 1989; Hicks et al., 1989). 이러한 기체상 오염물질의 침적현상은 대기질 관리에 있어서 오염물질의 적절한 감소계획을 산정ㆍ평가하기 위하여 지상 오염물질의 농도를 정확하게 추정하는 과정에서 필수적으로 고려되어야 하는 부분이다. (중략)

  • PDF

Characteristics of Air Quality in Seoul in Hot Season (서울지역 하절기의 대기질 특성 분석)

  • 정일록;한진석;홍유덕;김정수;조창래;마창민;이길철
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.233-234
    • /
    • 2001
  • 1997년부터 2000년 사이의 하절기(5~9월)의 평일(월~토요일)과 일요일(공휴일 포함)의 매 시간평균 미세먼지 및 오존의 농도특성을 분석하기 위하여 질소산화물(NOx), 오존(O$_3$), 미세먼지(PM10)등의 대기 오염물질을 한 시간단위로 자동측정하는 서울의 27개 측정소의 측정자료를 분석하였다. (중략)

  • PDF

Photochemical Reactions of Aromatic Hydrocarbons in Indoor and Outdoor Smog Chambers (실내/외 스모그 챔버에서 방향족계 탄화수소의 광화학 반응 비교 연구)

  • 안흥순;동종인
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.135-136
    • /
    • 2002
  • 최근 들어, 대도시 지역에서 오존(O$_3$)농도가 환경기준을 초과하는 빈도가 증가함에 따라 대기 중 광화학 대기오염현상과 그에 따른 오존 등 2차 광화학 오염물질에 대해 많은 관심이 집중되고 있다. 이러한 복잡한 대기중의 반응을 이해하고 해석하기 위하여 Smog Chamber를 이용한 대기 중 광화학 반응 연구가 진행 중에 있으며, 국내에서도 연구가 이루어지고 있다 Smog Chamber를 통해 대기 중의 광화학 반응의 세부적인 이해와 수학적 모델에 필요한 화학반응들의 변수를 제공하는 등 포괄적이고 종합적인 연구를 수행할 수 있다. (중략)

  • PDF

A Study on the Mushrooms Cultivation Using Ozon (오존을 이용한 버섯재배에 관한 연구(1))

  • Chang, Hyun-You;Byun, Jae-Myun;Nho, Moon-Gee;Park, Soon-Ae
    • Journal of Agricultural Extension & Community Development
    • /
    • v.7 no.1
    • /
    • pp.181-191
    • /
    • 2000
  • This experiment was conducted to find out the effects of mushroom cultivation on ozone susceptibility. The mushroom media in cultivation became softening well without bad Knell when it was soaked for 120 hours. The mushroom media softening on cultivating of oyster mushroom was good and fast when the concentration of gas condition ozone is high. The concentration of gas condition ozone must control at less than 0.02 ppm at the innoculation room, 0.03 ppm at the incubating room, must not use at the sprouting mom, less than 0.02 ppm at the growing room respectively. Also at the growing room, it removes the smell of mushroom, so has a protective effects of coming into mushroom fees and disease. When the concentration of 0.02 ppm liquid condition ozone was sprinkled, it was very useful in disease protection If it was input, the storage period of mushroom fruiting body was prolonged.

  • PDF

Removal Properties of Methylene Blue in Catalytic Ozonation (촉매오존화에 의한 메틸렌 블루 제거특성)

  • Chung, Jae-Woo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.3
    • /
    • pp.5-12
    • /
    • 2017
  • Effects of operating parameters such as activated carbon dose, gaseous $O_3$ concentration and pH on the properties of methylene blue(MB) degradation in a catalytic ozonation were investigated through a series of batch experiments. Activated carbon catalyzed the self-decomposition of ozone, generating $OH{\cdot}$, thus promoting MB degradation. Thus the increase of activated carbon dose enhanced the MB and TOC removal. The higher gaseous ozone concentration injected, the promoted MB and TOC removal obtained through the enhanced mass transfer. The MB removal was not significantly affected by the variation of aqueous pH. Catalytic ozonation can be considered as an efficient alternative in treating refractory pollutants in textile wastewater with faster and higher dye and TOC removal compared with ozonation and adsorption.

Characteristics of indoor air quality in the overground and underground railway stations (지상과 지하역사의 실내공기질 특성과 외기영향 평가)

  • Namgung, Hyeong-Kyu;Song, Ji-Han;Kim, Soo-Yeon;Kim, Hee-Man;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.17-25
    • /
    • 2016
  • In this study, the air quality of underground and overground railway stations was evaluated focusing on the degree of influence of the outside air quality. The measured components were particulate matter ($PM_{10}$), carbon dioxide ($CO_2$), carbon monoxide (CO), nitrogen dioxide ($NO_2$), formaldehyde (HCHO), ozone ($O_3$), total airborne bacteria (TAB), total volatile organic carbon (TVOC), and Radon (Rn), which are included in the maintenance standards and recommended standards of the Indoor Air Quality Management Act. Also, the indoor/outdoor concentration ratios of $PM_{10}$, $NO_2$, and $O_3$ were calculated to estimate the influence of the outdoor air quality. The concentrations of $PM_{10}$ HCHO, TVOC, $NO_2$, and Rn in the underground stations were found to be higher than those in the overground stations. These results indicate that the (present) generation of contaminants are caused by the indoor source of the underground station. The ozone concentration of the overground stations was higher than that of the underground stations, which indicates that the outdoor ozone concentration influenced that of the overground stations directly. Thus, methods of improving the IAQ should take into consideration the types of contamination.

Ozone Oxidation of PAHs in the Presence of Soil (I): Ozonation of Soil Slurry Phase (Ozone에 의한 PAHs 오염토양 복원 연구(I): 토양슬러리상 오존 산화)

  • Lim, Hyung-Nam;Kim, Ji-Yeon;Choi, Heechul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.5
    • /
    • pp.869-877
    • /
    • 2000
  • A mechanism of ozonation of simulated soil slurry contaminated by phenanthrene and benzo[a]pyrene has been studied under various conditions. The effects of soil media(BS, S, GB), radical scavenger, ozone input ratio(0.17~0.73mg/min), bicarbonate ion, and humic acid were investigated, BS showed the highest removal efficiency in media tested. The generation of OH-radical via the catalytic decomposition of ozone on active sites of the natural sand was confirmed by OH-radical scavenger experiments. The enhanced removal efficiency by OH-radical was indirectly quantified to be about 22%. As initial concentration of humic acid(as sodium salt) was increased, pseudo first-order rate constant ($k_o$) of phenanthrene was decreased from $1.37{\times}10^{-2}s^{-1}$ to $0.53{\times}10^{-2}s^{-1}$. The amount of ozone required to oxidize 80% of the initial mass of phenanthrene(10mg/kg) and benzo[a]pyrene(10mg/kg) was 67.2mg/kg-soil and 48.0mg/kg-soil, respectively.

  • PDF

Uncertainties of SO2 Vertical Column Density Retrieval from Ground-based Hyper-spectral UV Sensor Based on Direct Sun Measurement Geometry (지상관측 기반 태양 직달광 관측장비의 초분광 자외센서로부터 이산화황 연직칼럼농도의 불확실성 분석 연구)

  • Kang, Hyeongwoo;Park, Junsung;Yang, Jiwon;Choi, Wonei;Kim, Daewon;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.2
    • /
    • pp.289-298
    • /
    • 2019
  • In this present study, the effects of Signal to Noise Ratio (SNR), Full Width Half Maximum (FWHM), Aerosol Optical Depth (AOD), $O_3$ Vertical Column Density ($O_3$ VCD), and Solar Zenith Angle (SZA) on the accuracy of sulfur dioxide Vertical Column Density ($SO_2$ VCD) retrieval have been quantified using the Differential Optical Absorption Spectroscopy (DOAS) method with the ground-based direct-sun synthetic radiances. The synthetic radiances produced based on the Beer-Lambert-Bouguer law without consideration of the diffuse effect. In the SNR condition of 650 (1300) with FWHM = 0.6 nm, AOD = 0.2, $O_3$ VCD = 300 DU, and $SZA=30^{\circ}$, the Absolute Percentage Difference (APD) between the true $SO_2$ VCD values and those retrieved ranges from 80% (28%) to 16% (5%) for the $SO_2$ VCD of $8.1{\times}10^{15}$ and $2.7{\times}10^{16}molecules\;cm^{-2}$, respectively. For an FWHM of 0.2 nm (1.0 nm) with the $SO_2$ VCD values equal to or greater than $2.7{\times}10^{16}molecules\;cm^{-2}$, the APD ranges from 6.4% (29%) to 6.2% (10%). Additionally, when FWHM, SZA, AOD, and $O_3$ VCD values increase, APDs tend to be large. On the other hand, SNR values increase, APDs are found to decrease. Eventually, it is revealed that the effects of FWHM and SZA on $SO_2$ VCD retrieval accuracy are larger than those of $O_3$ VCD and AOD. The SZA effects on the reduction of $SO_2$ VCD retrieval accuracy is found to be dominant over the that of FWHM for the condition of $SO_2$ VCD larger than $2.7{\times}10^{16}molecules\;cm^{-2}$.

Characteristics of Electrical Properties, Ozone Generation and Decomposition of Volatile Organic Compounds by Nonthermal Plasma Reactor Packed with SBT Ferroelectric (SBT 강유전체 충전층 저온 플라즈마 반응기의 전기적 특성, 오존생성 및 휘발성유기화합물의 분해)

  • Eo, Joon;Kim, Il Won;Park, Jin Do;Lee, Joo Young;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.249-254
    • /
    • 2011
  • A nonthermal plasma reactor in conjunction with a tubular type with a ferroelectric (high-dielectric ceramic) pellet layer was designed and constructed. $SrBiTaO_9$ (SBT) pellets with 2.0 mm in diameter were held within the tube arrangement by two metal mesh electrodes (20 mm separation) connected to a high-voltage AC power supply. The dielectric constant of SBT pellets was 150 at room temperature and 500 at curie temperature ($335^{\circ}C$). The generation rate of ozone in the plasma reactor almost linearly increased with increasing applied voltage. In the case of the plasma reactor packed with SBT pellets the generation rate of ozone sharply increased at the applied voltage more than 20 kV. The ozone generation rate at the negative corona discharge was higher than that of the positive corona discharge. However, the destruction efficiency of toluene and methylene chloride was not increased in proportion to ozone concentration.