• Title/Summary/Keyword: 오일 공급

Search Result 395, Processing Time 0.03 seconds

Induction of Red Discoloration in Rice var. Tongil with Certain Metabolic Inhibitors (대사저해제에 의한 "통일"벼 적고현상 유발에 관하여)

  • Beyoung-Hwa Kwack;Chan Kim
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.15
    • /
    • pp.115-121
    • /
    • 1974
  • Artificial induction of nitrogen deficiency symptoms (leaf chlorosis) with two root respiratory inhibitors(DNP and Na$_2$S) was studied and regarded to be the same characteristic to red discoloration in rice var. Tongil seedling leaves as well as adult ones. Tongil(IR 667) was shown to be more nitrogen sensitive and have more distinctive appearance of the leaf discoloration than Punggwang(a native Japonica-type varity.) Conclusions were drawn from the present data that so-called red discoloration of Tongil under the natural field conditions is brought about either by insufficient nitrogen supply in soils or certain factors which may limit at any time the root absorption of nitrogen (low temperature, toxic gases or substances, poor drainage, around roots, etc.) in soils even with ample supply of it.

  • PDF

Failure analysis of a turbo molecular pump in semiconductor equipments (반도체 장비에서 터보 분자 펌프의 파손 사례 연구)

  • Jeong, Jin-Yong;Ju, Jeong-Hun;O, Sam-Gyun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.120-120
    • /
    • 2018
  • 반도체 소자나 디스플레이 패널 제조 공정에 가장 많이 사용되는 진공 펌프인 터보 분자 펌프는 오일을 사용하지 않고, 설치 방향이 자유로우며 넓은 작동 압력 영역을 가지고 있어서 고가임에도 불구하고 점점 더 사용 영역을 넓혀 가고 있다. 상하의 두 곳에 회전축을 지지하는 베어링이 필요한데, 기계식 금속 베어링을 채용하는 경우에는 반드시 윤활유를 공급해 주어야 하고, 고온, 부식성 또는 산화성 가스의 배기 시에는 퍼지 가스로 비활성인 질소나 알곤등을 이용하여 보호를 해주어야 한다. 반면, 자기 베어링을 채택한 모델은 윤활의 걱정에서 자유로울 수 있기 때문에 채용이 늘어나고 있다. 동일극의 반발력이나 반대극의 인상력을 이용한 구조를 갖게 되는데 갑작스러운 입구 쪽 압력의 증가 시에는 자석 끼리 부딪치는 일이 발생하고 이로 인해서 로터 모듈 전체에 큰 손상을 갖게 되므로 한 곳 정도에 비상용 터치 다운 베어링을 기계식으로 윤활제 없이 설치하기도 한다. 기본적으로 자기 베어링 방식은 로터 모듈의 부상과 제어를 위해서 3축 또는 5축 제어를 하게 되는데 여기에는 전자석의 전류를 미세하게 조정하여 피드백 하는 시스템을 활용하기 때문에 외부에서의 자기장이 일정값 이상 침투하게 되면 제어 회로의 기능에 문제를 일으키게 된다. 또한 축 방향에 수직인 자기장의 강도가 높아지면 고속으로 회전하는 금속 블레이드가 자속을 자르게 되므로 표면에 와전류가 발생하여 문제가 된다. 터보 분자 펌프는 회전자와 고정자 간격이 1 mm 이내로 작아서 약간의 진동이라도 발생하면 회전자와 고정자 간에 충돌이 일어나고 이는 곧 파손으로 이어진다. 그림 1에는 파손 원인 분석을 위한 회전자 모듈의 수치 해석용 모델의 일부를 나타내었고, 그림 2에는 실제로 외부 자기장에 의한 파손이 발생한 사례의 자기 베어링 모듈의 사진을 나타내었다. 본 발표에서는 외부 자기장의 형태에 따라 제어 자기장에 미치는 영향을 CFD-ACE+(ESI corp)를 활용하여 해석하였다.

  • PDF

Optimal Feeding Rates of Subadult Korean Rockfish Sebastes schlegeli Fed a Commercial Diet at Different Water Temperatures (저수온, 적수온, 고수온에서 미성어기 조피볼락(Sebastes schlegeli)의 배합사료 적정 공급률)

  • Kim, Min-Gi;Lee, Cho-Rong;Kim, You-Jeong;Oh, Dae-Han;Lee, Bong-Joo;Kim, Sung-Sam;Lee, Kyeong-Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.3
    • /
    • pp.322-328
    • /
    • 2015
  • Three feeding trials were conducted to investigate the optimal feeding rates of subadult Korean rockfish Sebastes schlegeli at low, optimal and high water temperatures. In Exp-I, triplicate groups of fish (248 g) were fed a commercial diet (CD) with five different feeding rates of 0.1%, 0.2%, 0.4%, 0.6% and 0.8% body weight per day for 10 weeks at the low temperature ($11.6-15.2^{\circ}C$). In Exp-II, fish (129 g) were fed the same CD with five different feeding rates of 0.4%, 0.8%, 1.2%, 1.6% and 2.0% body weight per day for 10 weeks at the optimal temperature ($16.0-18.8^{\circ}C$). In Exp-III, fish (85.7 g) were fed the same CD with five different feeding rates of 0.4%, 0.8%, 1.2%, 1.6% and 2.0% body weight per day for 12 weeks at the high temperature ($21.0-28.5^{\circ}C$). The optimal feeding rates in the low, optimal, and high water temperatures were estimated to be 0.56%, 0.93% and 1.17% body weight per day, respectively, for subadult Korean rockfish.

Ceramic Membrane Application for the Bayer Process of Aluminium hydroxide Production (수산화알루미늄 제조 Bayer 공정에서 Ceramic membrane 여과 실용화 공정 개발)

  • 김정학;이성오;구자경;남승하;이시철
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.146-148
    • /
    • 2003
  • Bayer 공정은 가성소다를 이용하여 보오크사이트로부터 수산화알루미늄을 추출하는 공정이다. 그러나 보오크사이트 추출 후 1차 침전공정에서 반응한 보오크사이트 잔사는 침전시킴으로써 깨끗한 공정액을 분리하는 데 이때 침전되지 못한 다량의 분산성 고형물이 공정액 중에 존재하게 되는데 이를 분산성 보오크사이트(레드머드) 미립자라하며 보통 80-100mg/$\ell$의 농도를 나타낸다. 그러므로 이를 제거하기 위해 다음 공정인 입상여과필터 공정을 사용하는데 이때 필터링 효율증대를 위해 보조제로써 다량의 소석회(Ca(OH)$_2$)를 투여하여 공정액 중의 고형물을 농도를 8-100mg/$\ell$에서 5mg/$\ell$로 낮추는 공정을 사용하고 있다. 특히 국내 수산화알루미능 제조회사일 KC(주)의 경우 소석회 사용량이 일 10톤, 년간 약 3,600톤을 사용함으로써 소석회의 사용량에 따라 같은 량의 슬러지가 발생되게 된다. 따라서 여과후 발생되는 슬러지의 처리비용 문제(연간 9천만원)와 소석회의 미립자에 의한 공정액의 2차 오염과 제품 품질 저하(quality claim) 및 소석회 사용량에 따른 연간 원료비(연간 3억원) 등의 상당한 문제점을 나타내고 있는 실정이다. 아울러 최근 고품위 수산화알루미늄의 공급 요구에 따라 여과시 정제기준이 점차 낮아져 이제는 1mg/$\ell$ 이하를 유지하여야 하는 근본적인 문제에 봉착해있는 실정이다. 그러므로 본 연구에서는 소석회를 사용하는 입상여과법을 대체하기 위한 신공정개발을 추진하였으며, 그동안 카트리지여과법 등의 다양한 실험 결과로부터 최근 필터 보조제를 첨가하지 않는 물리적 여과방법인 세라믹 막 여과법의 적용 가능성을 확인하고 친환경공정인 세라믹 막 여과 실용화 공정 기술을 개발하였다. 세라믹 막 여과 법은 여과 보조제를 사용하지 않으므로 2차적인 슬러지 발생등의 환경문제를 발생하지 않으며, 공정액에 첨가제를 투입하지 않으므로 순환형 친환경공정으로 각광받을 수 있다. 본 연구에서는 고온, 고농도의 NaOH 수용액의 처리에 적합한 막소재와 발생될 수 있는 제반 문제점 등을 파악하였고, 장기간의 실험을 거쳐 최적 투과 압력(Trans membrane pressue), 세정 조건 및 주기, 막재질에 있어서 보강하여야 할 Point, 최적 운전 조건들을 토출해 내었고, 향후 실제 Plant에 적용할 계획이다.

  • PDF

Production of Bioplastics from Activated Sludge in a Mixed Culture (혼합배양계에서 활성오니를 이용한 생분해성플라스틱 생산 연구)

  • Cho, Jae-Kyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.3
    • /
    • pp.119-126
    • /
    • 2001
  • A process for the production of bioplastics from wastewater with an open microbial culture was developed and evaluated. The process consists of a selection reactor to select bacteria in feast/famine regime and an accumulation reactor to produce PHA using selected bacteria. Polyhydroxyalkanoate(PHAs) accumulating bacteria could be efficiently grown in a sequencing batch reactor(SBR) without any growth limitation. For the high production of PHA limitation such as oxygen and nutrients seemed to be needed. Accumulation experiments were performed to evaluate the level of accumulation of PHA. Limited aeration had no effect, but nutrients limitation showed high accumulation. Bacteria which were selected in the SBR could accumulate PHA till 60% of cellular dry weight in accumulation experiments under nitrogen limitation. PHA accumulation rate decreased with increasing PHA content in the cells. Clearly, PHA accumulation rate has a strong correlation with the PHA content of the cells.

  • PDF

Comparison of Quality and Cell Enlargement of 'Nero' Black Chokeberry Fruits According to Different Soil Water Conditions (토양수분 조건에 따른 블랙쵸크베리 'Nero' 과실의 품질 및 세포 발달 비교)

  • Won, Jungyeon;Shin, Hyunsuk;Oh, Youngjae;Han, Hyeondae;Kim, Keumsun;Oh, Sewon;Kim, Daeil
    • Korean Journal of Plant Resources
    • /
    • v.30 no.1
    • /
    • pp.88-95
    • /
    • 2017
  • Effects of different soil water conditions on fruit characteristics were investigated in 5-year-old 'Nero' black chokeberry trees (Aronia melanocarpa). Three kinds of drought stresses, including low water deficit, severe water deficit, and very severe water deficit, due to decline of soil water decreased the fruit quality of weight of 10 berries, soluble solid content, and anthocyanin, compared with the control (consistent water supply) during the harvest period. After longer drought stress, supply of soil water could induce berry cracking because cell size of epidermis of fruits contracted, whereas cell size of sub-epidermis and flesh expanded. Thus periodic water supply using water supply facility is needed for yield and quality of 'Nero' black chokeberry fruits.

An Experimental Study on Material Property of Parking Zone Flooring Occupancy Surface Finishing Used to Environment-friendly.High-liquidity Ceramic Resin Mortar (친환경.고유동 세라믹 수지 모르타르를 이용한 주차장 바닥용 표면 마감의 재료적 특성에 관한 실험적 연구)

  • Lee, Sun-Gyu;Moon, You-Seok;Lee, Hyung-Jun;Lee, Wan-Hwi;Oh, Sang-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.829-832
    • /
    • 2008
  • Since the early 1980s, the building is dramatically higher increases. Therefore, the shortage of parking spaces as a social problem has been pointed out. The parking lot utilization of underground space is increasing by like this problem solving countermeasure. However, Most of the organic material is used for construction in the parking lot on the floor. The existing parking zone flooring occupancy surface finishing is harmful gases and environmental hormones cause of the worker. The study on the safety of the worker consider using environment-friendly?high-liquidity ceramic resin mortar materials to evaluate the characteristics and physical properties.

  • PDF

Development of Reliability Contribution Function of Power System including Wind Turbine Generators combined with Battery Energy Storage System (풍력발전기와 BESS를 결합한 전력계통의 공급신뢰도 기여함수)

  • Oh, Ungjin;Lee, Yeonchan;Choi, Jaeseok;Yoon, Yongbeum;Chang, Byunghoon;Cha, Jun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.371-381
    • /
    • 2016
  • This paper presents a study on reliability assessment and new contribution function development of power system including Wind Turbine Generator(WTG) combined with Battery Energy Storage System(BESS). This paper develops and proposes new reliability contribution function of BESS installed at wind farms. The methodology of reliability assessment, using Monte Carlo Simulation(MCS) method to simulate sample state duration, is proposed in detail. Forced Outage Rate(FOR) considered probabilistic approach for conventional generators is modelled in this paper. The penetration of large wind power can make risk to power system adequacy, quality and stability. Although the fluctuation of wind power, BESS installed at wind farms may smooth the wind power fluctuation. Using small size system as similar as Jeju island power system, a case study of reliability evaluation and new proposed contribution function of power system containing WTG combined with BESS is demonstrated in this paper, which would contributes to BESS reliability contribution and assessment tools of actual power system in future.

Design and Test of Thermal Control and Fire Safety System for Space Launch Vehicle (발사체 열제어/화재안전 시스템 설계 및 시험)

  • Ko, Ju Yong;Oh, Taek Hyun;Lee, Joon-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1006-1010
    • /
    • 2017
  • This paper describes the design and test of the thermal control and fire safety system for thermal control and the fire/explosion prevention of inside the compartment during the preparation and operation of the space launch vehicle at the launch pad. The system considered here is for the test launch vehicle which is being developed as part of the development of the Korean Space launch vehicle-II. This system applies the high pressure system based on the heritage of Naro launch vehicle. The selection of thermal control and fire safety system from high pressure and low pressure system is done in consideration of the characteristics of the launch pad gas supply system and the characteristics of launch vehicle, and the system configuration is also changed accordingly. As a result, it has been confirmed that the developed system satisfies the initial design conditions through the test. Moreover the system will be applied to the development of the Korean launch vehicle in the future.

  • PDF

Conversion Function and Relationship of Loss of Load Expectation Indices on Two Kinds of Load Duration Curve (두 종류의 부하곡선에 관한 공급지장시간기대치(LOLE)의 상호 변환관계성)

  • Lee, Yeonchan;Oh, Ungjin;Choi, Jaeseok;Cha, Junmin;Choi, Hongseok;Jeon, Donghun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.475-485
    • /
    • 2017
  • This paper develops a conversion function and method transforming from daily peak load curve used $LOLE_D$ [days/year] to hourly load curve used $LOLE_H$[hours/year]and describes relationship between $LOLE_D$ [days/year] and $LOLE_H$ [hours/year]. The indices can not only be transformed just arithmetically but also have different characteristics physically because of using their different load curves. The conversion function is formulated as variables of capacity and forced outage rate of generator, hourly load daily load factor and daily peak load yearly load factor, etc. Therefore, the conversion function (${\gamma}={\varphi}$(.)) can not be simple. In this study, therefore, the function is formulated as linear times of separated two functions. One is an exponential formed conversion function of daily load factor. Another is formulated with an exponential typed conversion function of daily peak load yearly load factor. Futhermore, this paper presents algorithm and flow chart for transforming from $LOLE_D$[days/year] to $LOLE_H$[hours/year]. The proposed conversion function is applied to sample system and actual KPS(Korea Power System) in 2015. The exponent coefficients of the conversion functions are assessed using proposed method. Finally, assessment errors using conversion function for case studies of sample system and actual system are evaluated to certify the firstly proposed method.