• 제목/요약/키워드: 오염된 공기

검색결과 885건 처리시간 0.026초

실내공기 중 생물학적 오염물질에 관한 국내 연구 동향 (Trend in Study of Biological Pollutants in Indoor Air Quality in Korea)

  • 허은혜;원동환;문경환
    • 한국환경보건학회지
    • /
    • 제38권4호
    • /
    • pp.300-310
    • /
    • 2012
  • Objectives: Indoor air quality problems in public spaces have recently become a very important issue in South Korea, because many spend a long time every day indoors. In this study, an extensive literature review was performed on the subject of suspended bacteria and fungi in public facilities. The objective of this study was to evaluate the extent and types of suspended bacteria and fungi in indoor air in South Korea. This study will provide direction to the research in the field of indoor air. Methods: Article reviews was conducted using a search engine and the following keywords; 'bacteria', 'total suspended bacteria', 'fungi' and 'indoor air' from published articles since 2000. Results: Most of the places of measurement were schools, kindergartens, childcare centers and general hospitals. The highest concentrations of total suspended bacteria and fungi were found in schools and kindergartens. Some public facilities exceeded the standard of 800 CFU/$m^3$. There were few studies on other suspended bacteria: Gram Negative Bacteria, Staphylococcus and Klebsiella pneumoniae. Conclusions: It appears that more studies with intensive controls are needed. It was found that schools and kindergartens were most susceptible to microbial indoor air pollution. These results may be able to suggest an indoor standard for suspended bacteria and fungi in South Korea.

음이온 처리된 몇 가지 새싹채소의 생장과 세균 수 (Growth of and Bacterial Counts on Several Edible Sprouts Exposed to Spray Ionization)

  • 송민정;전유민;오명민
    • 생물환경조절학회지
    • /
    • 제24권1호
    • /
    • pp.45-50
    • /
    • 2015
  • 새싹은 영양분이 풍부한 식품이다. 하지만 생산 과정에서 종피에 있는 미생물에 의한 오염 가능성이 존재한다. 이 실험의 목적은 음이온 처리가 새싹의 생장과 살균에 미치는 효과를 구명하는 것이다. 음이온 처리는 4종류의 새싹의 생장과 살균효과에 긍정적인 효과를 보였다. 대조구에 비해 음이온 처리한 적양배추와 케일 새싹의 배축길이는 약 1.26배 증가하였으며, 상추, 적양배추, 케일 유근의 길이는 1.4~1.6배 증가하였다. 모든 새싹의 생체중은 음이온 처리했을 때 대조구에 비해 16.0~38.5% 유의적으로 증가하였다. 유근의 활력 또한 음이온 처리가 대조구에 비해 유의적으로 높은 수치를 보였다. 음이온 처리된 상추, 적양배추, 다채 새싹의 일반 세균 수는 대조구에 비해 각각 41%, 66%, 19% 감소하였으며, 배수되는 물의 세균 수 또한 감소되었다. 결국 음이온처리는 새싹의 생장을 향상시켰으며, 동시에 살균하는데도 효과적이었다.

견운모와 규조토에 대한 암모니아 기체의 흡착특성 (Adsorption characteristics of the sericite and diatomite for ammonia gas)

  • 이수승;김진수;윤창연;이종협
    • 청정기술
    • /
    • 제12권3호
    • /
    • pp.175-181
    • /
    • 2006
  • 실내 공기오염 방지를 위하여 견운모와 규조토를 건축내장재로 사용하기 위한 물리 화학적 특성을 조사 하였다. 특히 규조토의 경우 주사전자현미경(Scanning Electron Microscope: SEM)으로 표면에 분포하는 규조화석의 존재를 확인하였으며, 질소흡탈착법(Brunauer-Emmett-Teller (BET) method)을 통해 5 nm 이하의 기공이 고르게 분포하고 비교적 넓은 비표면적을 가지는 것을 알 수 있었다. 이러한 규조토와 비교하여 견운모는 기공특성이 보이지 않았으며 비표면적 역시 상대적으로 작은 것으로 나타났다. 따라서, 다공질 구조와 넓은 비표면적으로 인해 규조토가 견운모보다 상대적으로 높은 흡착특성을 가지고 있음을 예상 하였으며, 이를 실험적으로 확인 하였다. 하지만 $950^{\circ}C$이상으로 열처리한 결과 규조토는 다공질 규조화석의 연소 및 무기성분의 고온소결로 인해 더 이상 기공 구조를 보이지 않고 비표면적이 감소하였으며, 그 결과 흡착성능 또한 감소하는 경향을 보였다. 결론적으로, 열처리 하지 않은 규조토의 경우 규조화석의 존재로 인해 다공질 구조를 가지며, 넓은 비표면적에 의해 보다 높은 암모니아 흡착특성을 보여 실제로 이와 같은 유해 화합물을 효과적으로 제거할 수 있는 능력이 있음을 보였다.

  • PDF

건강위해성평가에 의한 사무실 실내공기오염물질의 관리항목 확대 (Extension Possibility of Indoor Air Standards in Office Building by Health Risk Assessment)

  • 노영만;이철민;김윤신;김석원;김치년;김현욱;조기홍;최호춘;김정만
    • 한국산업보건학회지
    • /
    • 제16권1호
    • /
    • pp.54-67
    • /
    • 2006
  • This study was performed to deduct the extension possibility of the standards establishment for $NO_2$, $O_3$, Asbestos, Radon, total volatile organic compounds (TVOC) excluded in the indoor air part of Industrial Safety Acts in Korea. The air pollutants were sampled for 30 office buildings from August to September, 2005 in the metropolitan area. The airborne concentrations of $NO_2$, $O_3$, Radon and TVOC were 0.0092 ppm, 0.0035 ppm, 0.57 pCi/L and $423{\mu}g/m^3$, respectively. The management plan and reduction methods is required in the aspect of indoor air quality(IAQ) because the emission sources of those also exist in indoor as well as outdoor even though those were not exceeded the standards of the Ministry of Environment in Korea. The standard for TVOC in the new and remodeling office has to be established based on the risk assessment when hazard index exceeded "1" in the worst case scenario. In the state of art, the management of each volatile organic compounds has a difficulty due to not enough data for toxicological reference. Therefore, it is suggested that first of all, the standard for TVOC be established and then expanded to each materials for decision-making of improvement of IAQ in office.

유류오염대수층 공기분사공정상의 미생물 제한효소다형성법 적용 평가 (Analysis of Microbial Community in the TPH-Contaminated Groundwater for Air Sparging using Terminal-Restriction Fragment Length Polymorphism)

  • 이준호;이상훈;조재창;박갑성
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.590-598
    • /
    • 2006
  • In-situ Air sparging (IAS) is a groundwater remediation technique, in which organic contaminants volatilize into air form the saturated to vadose zone. This study was carried out to evaluate the effect of sludge and soil microbial community structure on air sparging of Total Petroleum Hydrocarbons (TPH) contaminated groundwater soils. In the laboratory, diesel (10,000 mg TPH/kg) contaminated saturated soil. The Air was injected in intermittent (Q=1500 mL/min, 10 minute injection and 10 minute idle) modes. For Terminal-Restriction Fragment Length Polymorphism (T-RFLP) analysis of eubacterial communities in sludge of wastewater treatment plants and soil of experiment site, the 16S rDNA was amplified by Polymerase Chain Reaction (PCR) from the sludge and the soil. The obtained 16S rDNA fragments were digested with Msp I and separated by electrophoresis gel. We found various sequence types for experiment with sludge soil samples that were closely related to Agrococcus, Flavobacterium, Thermoanaerobacter, Flexibacter and Shewanella, etc, in the clone library. The results of the present study suggests that T-RFLP method may be applied as a useful tool for the monitoring in the TPH contaminated soil the fate of microorganisms in natural microbial community.

서울지역 지하철역의 공기 중 오염인자의 노선별 분포 특성 (Distribution Characteristics between Line and Line for Indoor Air Pollutant Factors at Subway Stations in Seoul Area)

  • 김민영;라승훈;신도철;한규문;최금숙;정일현
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.134-144
    • /
    • 1998
  • A comprehensive air quality monitoring was carried out to investigate the criteria concentration of air pollutant in indoor of subway stations of Seoul City. The samples were collected twice per year (the first and the second half of the year) at each sampling point from February to September in 1997. Sampling point of subway stations was ticket office and platform. The measurement of indoor air pollutants such as sulfur dioxide(SO$_2$), nitrogen dioxide(NO$_2$), carbon monoxide(CO), carbon dioxide(CO$_2$), total suspended particulate(TSP) was performed to determine the indoor air quality. Heavy metals(Pb, Cd, Cu, Cr, As, Hg) were also measured together with those air pollutants. The annual average concentration of CO$_2$ and TSP in subway stations were relatively high while those of heavy metals were within 10% of environmental recommended standard concentration in all stations. As results of regression analysis between line and line of air factors, the concentrations of CO, CO$_2$, TSP, Pb, Cd, Cr and Cu were highly correlated, but those of $SO_2, NO_2$ and Hg were not correlated. As results of regression analysis between ticket office and platform, the concentrations of heavy metals such as Cr and Cu were highly correlated. Results of oneway analysis of variance between the first and the second half of the year air factors also indicated that CO, CO$_2$, Cd, Cu, Hg were significant($\alpha$=0.01), respectively. The average contration of total suspended particulate(TSP) in subway line No. 1 was shown high concentration(200 $\mu g/m^3\cdot$ day) level.

  • PDF

석탄화력발전소 보일러 연소계통의 모델개발에 관한 연구 (A Stduy on Model Development of Boiler Combustion System on Coal Fired Power Plant)

  • 문채주;김용구;정환주
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.65-73
    • /
    • 2004
  • 석탄화력발전소의 보일러계통은 구성기기 사이에 수많은 상호관계를 갖는 대규모, 비선형 계통이다. 이러한 복잡한 계통의 해석에서 동특성 모의는 대규모 상호관계를 지속적으로 추적하는 강력한 방법으로 인식되고 있다. 보일러계통은 공기/가스 시스템과 물/증기 시스템으로 구성된다. 보일러의 오염물질 배출에 관한 최근 환경규제의 강화와 보일러의 물성치에 대한 설게 검증 요건 때문에 상업용 프로그램이 보일러 계통의 해석에 사용된다. 이 논문에서는 모의 도구로써 EPRI(미국전기연구소)에서 개발한 MMS를 사용하여 모델개발을 논의하였다. MMS에서 사용하여 개발된 모델은 한국표준석탄화력발전소의 보일러 연소계통에 대한 설계 및 현장데이터를 시험하였다. 개발된 모델은 정상상태 및 천이상태 조건에서 ${\pm}$5% 이내로 연소계통이 잘 응답하는 것으로 결과에서 보여준다. 이 논문에서 연소계통의 해석에 대한 개발된 모델은 일반적일고, 어떤 형식의 석탄호력발전소에도 적용이 가능하다.

메탄올 연료형 SOFC/GT 하이브리드시스템의 성능 평가 (Performance Analysis of Methanol Fueled Marine Solid Oxide Fuel Cell and Gas Turbine Hybrid Power System)

  • 오세진;임태우;김종수;길병래;박상균;김만응;이경진;오진숙;김명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권8호
    • /
    • pp.1040-1049
    • /
    • 2010
  • GHG 및 대기오염물질 배출 규제는 고효율 및 친환경에 적합한 새로운 선박용 동력장치의 필요성을 제기하고 있다. 최근 이와 같은 문제들을 근본적으로 해결하기 위한 지속가능한 방법으로서 연료전지를 선박의 동력발생장치로 도입하고자 하는 검토가 진행되고 있다. 본 논문은 액체연료인 메탄올을 기반으로 한 고체산화물형 연료전지/가스터빈 하이브리드시스템의 성능을 평가한 것으로 스택의 작동온도, 전류밀도, 가스터빈 압력비, 공기예열기 온도효율, TIT(turbine inlet temperature)의 영향을 시뮬레이션으로 검토하고 그 결과를 기체연료인 메탄의 경우와 비교하고 있다.

친구구역 활용에 관한 특별법의 성립과 운용에 관한 연구 (A Study on the Establishment and Operation of the Special Law on Waterfront Area)

  • 박성제;류시생
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2011년도 학술발표회
    • /
    • pp.112-112
    • /
    • 2011
  • 2010년 12월 8일 국회 본회의에서 "친수구역 활용에 관한 특별법"(이하 친수법)이 통과되었다. 친수법은 국가하천의 양안 2km 이내의 지역을 엄격한 기준에 의해 친수구역으로 지정하여 체계적으로 개발하도록 제도화하였다. 또한 특히 사업시행자를 공기업 및 지방자치단체 등 공공기관으로 제한하고 개발이익도 하천정비에 재투입하여 개발이익이 사유화되거나 이윤추구의 장이 되지 않도록 하는 법적 토대를 마련하고 있다. 우리나라의 하천은 지난 수십 년간 개발일변도 정책으로 하천 본래의 모습을 찾기 어렵다. 인구의 도시집중, 지속적인 개발, 하천에 대한 기대치 증가 등으로 앞으로도 하천 자체의 자정능력에 의한 회복은 기대하기가 쉽지 않다. 4대강 살리기 사업(이하 4대강사업)은 국내 하천의 이러한 절실한 현실이 고려되었다고 한다. 그런데 4대강사업으로 조성되는 수변지역을 그대로 방치하면 무분별한 난개발과 토지투기의 장으로 전락할 가능성이 크다. 또한 수변구역 주변의 넓은 토지는 이미 농경지화되어 있어 비료, 제초제 등 비점오염원의 하천유입으로 수질을 지속적으로 위협하고 있다. 이러한 제반 여건들이 친수법 제정의 주요한 동기가 되었다고 한다. 그러나 친수법의 제정에는 수많은 우여곡절이 포함되어 있다. 친수법은 법안이 발의된 이래 법안의 취지를 둘러싸고 향후 법 실행과 관련된 논의가 첨예하게 대립하여왔다. 본 연구는 이미 제기된 특별법의 문제점에 대하여 법적인 관점에서 짚어보고, 그에 따른 개선방안을 모색해 보고자 한다. 친수법의 제정을 위하여 꼭 특별법이라는 입법과정을 거쳐야 했는지 그리고 친수법이 상정하고 있는 사업의 성격 및 내용에 대한 법적인 타당성을 살펴보고자 한다. 또한 친수법 제4장에서 규정하고 있는 하천관리기금을 법률 구성의 입장에서 어떻게 파악할 수 있는지에 관한 점도 고찰하였다. 즉, 친수법이 구상하고 있는 [특별법의 제정${\rightarrow}$친수구역 개발에 의한 수익 창출${\rightarrow}$하천기금의 조성${\rightarrow}$건전한 하천관리]의 구도가 법적으로 어느 정도 균형과 조화를 이룰 수 있는지 고찰하였다.

  • PDF

주택 실내 공기중 오염물질 농도의 동절기와 하절기 비교 분석 (A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and Summer)

  • 남기철;이영한;최봉석
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.125-131
    • /
    • 2017
  • Purpose: The study is to measure concentrations of indoor air pollutants in housing and to analyze the characteristics of pollutants in housing indoor-air between summer and winter comparatively. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in winter which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. The characteristics of HCHO, TVOC, $CO_2$ concentration in winter were analyzed and then the concentrations in winter were analyzed the concentrations in summer being preceding research comparatively. Result: Average concentration of TVOC in winter was 2.7 times more than that of TVOC in summer, average concentration of HCHO in winter was about 2.0 times more than that of HCHO in summer. Average concentration of $CO_2$ in the morning at living room in winter was 1.3 times more than that of $CO_2$ in summer. Average concentration of $CO_2$ in the morning at master bedroom in winter was 1.1 times more than that of $CO_2$ in summer. Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close or over to 1,000ppm being criteria of the Ministry of Environment.