• Title/Summary/Keyword: 열 유속

Search Result 752, Processing Time 0.027 seconds

Numerical study on the pressure drop and heat transfer enhancement in a flat-plate solar collector (평판형 태양열 집열기의 압력강하 및 열전달 성능 향상에 관한 수치해석적 연구)

  • Heo, Joo-Nyoung;Shin, Jee-Young;Lee, Dooho;Son, Young-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.316-323
    • /
    • 2013
  • The use of artificial roughness in various forms of shapes and sizes is the most common and effective way to improve the performance of a flat-plate solar collector. In the present study, numerical analysis on heat transfer and pressure drop was performed in a rectangular channel with various rib arrays. The uniform heat flux is applied to the channel from the upper side. The forms of ribs considered in this study were rib $90^{\circ}$, groove $90^{\circ}$, groove $60^{\circ}$, baffle $90^{\circ}$, baffle $60^{\circ}$, wave $90^{\circ}$ and wave $60^{\circ}$. Air is the working fluid, and the Reynolds number ranges from 3200 to 17800. Nusselt number and friction factor were investigated to predict the performance of the system with various type of ribs. The average Nusselt number and pressure drop were increased with the increase of velocity in all types of ribs. The highest heat transfer and pressure drop occurred for the baffle $90^{\circ}$, but highest performance factor considering heat transfer and pressure drop together occurred for the groove $60^{\circ}$. Therefore, heat transfer and pressure drop should be considered together when a flat plate solar collector is designed.

Study on the Thermal Characteristic Comparison of Fire.Explosion Hazard of Fugitive Dust Generated in the Manufacturing Process (제조공정상 발생하는 비산분진의 화재·폭발 위험성에 대한 열적특성 비교에 관한 연구)

  • Sun, Ko Jae
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.71-83
    • /
    • 2014
  • This study carried out an experiment in order to compare thermal characteristics after collecting dust generated in the process of disposing of waste tire, plywood flour in the process of manufacturing plywood, salicylic acid dust in the process of manufacturing functional soap, and dust in the process of manufacturing wheat powder, which has potential fire and explosion hazard. According to the results of experiment, the analysis showed that all samples subject to the experiment were in the condition where heat flux decreased and temperature decreased as the quantity of added talc was increased. This shows that decomposition rate decreased, and hazard decreased. However, in all of samples subject to the experiment, as heating rate increased, endothermic onset temperature moved to the low-temperature part, and the amount of absorbed heat was largely increased. This showed that the decomposition hazard of sample increased as heating rate increased, according to the analysis. Besides, TGA experiment results showed that thermal stability was secured because total weight loss decreased as the amount of talc was increased for all samples subject to the experiment regarding the ratio of weight loss. It is expected that the continuous research and supplementation of dust explosion mechanism in the future will contribute to the establishment of measures for the effective dust explosion prevention.

Comparative Studies of Thermal Insulation Performance of Life Vests by Numerical Analysis and Experiment (보온 재료에 따른 구명 조끼 별 단열성능의 비교 실험 및 해석)

  • Kim, Sung-Chan;Lee, Kyung-Hoon;Hwang, Se-Yun;Jang, Ho-Sang;Lee, Jang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.40 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Although the life jacket can provide the buoyance with the drowner, heat loss can make the drowned individual be subject to the hypothermia. In this study, The thermal insulation of two types life jacket including inflatable and foam type were evaluate by both experiments and numerical analysis. To estimate the thermal resistance of the jackets, experiments on the heat flux were conducted by the thermal manikin exposed to cold water. Heat flux loss on the surface of thermal manikin were measured for both foam and inflatable type life jacket. Also, finite element method is applied to a body section in order to understand the level of hypothermia of each life jacket. The segmental of human thigh is represented by a multi-layered section which considers the heat conduction within tissue, bone and fat. As a result, the thermal resistance and hypothermia time of each jackets have been compared based on the finite element analysis. It was found that the insulation ability of suggested life jackets is better than that of conventional type.

Validation of FDS for Predicting the Fire Characteristics in the Multi-Compartments of Nuclear Power Plant (Part I: Over-ventilated Fire Condition) (원자력발전소의 다중 구획에서 화재특성 예측을 위한 FDS 검증 (Part I: 과환기화재 조건))

  • Mun, Sun-Yeo;Hwang, Cheol-Hong;Park, Jong Seok;Do, Kyusik
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.31-39
    • /
    • 2013
  • The Fire Dynamics Simulator (FDS) has been applied to simulate a full-scale pool fire in well-confined and mechanically ventilated multi-compartments representative of nuclear power plant. The predictive performance of FDS was evaluated through a comparison of the numerical data with experimental data obtained by the OECD/NEA PRISME project. To identify clearly the FDS results regarding to the user-dependence in the process of FDS implementation except for the intrinsic limitation of FDS such as simple combustion model, only the over-ventilated fire condition was chosen. In particular, the importance of accurate boundary conditions (B.C.) in mechanically ventilated system were discussed in details. It was known from FDS results that the B.C. on inlet and outlet vents did significantly affect the thermal and chemical characteristics inside the compartments. Finally, it was confirmed that the FDS imposed an accurate ventilation B.C. provided qualitatively good agreement with temperatures, heat fluxes and concentrations measured inside the nuclear-type multi-compartments.

Combustion Properties of the Quercus variabilis and Zelkova serrata Dried at Room Temperature (II) (자연 건조된 굴참나무와 느티나무 목재의 연소성(II))

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.21 no.4
    • /
    • pp.469-474
    • /
    • 2010
  • Wood has an essential drawback such as high combustion ability. The purpose of this paper is to examine the combustion properties of the quercus variabilis and zelkova serrata dried at room temperature. The cone calorimeter (ISO 5660-1) was used to determine the heat release rate (HRR) and fire smoke index, as well as CO/$CO_2$ production and smoke obscuration. The total heat release (THR), $140.2\;MJ/m^2$ of the quercus variabilis under an external $50\;kW/m^2$ was high in comparison with THR $85.7\;MJ/m^2$ for the zelkova serrata. Furthermore, the quercus variabilis has high total smoke production (TSP), $3.50\;m^2$ compared with TSP $0.65\;m^2$ of zelkova serrata. Thease results depend on the bulk density of tested wood species. In addition, the CO/$CO_2$ production ratio of zelkova serrata and quercus variabilis was measured as 0.053, 0.043, respectively. Also, zelkova serrata showed an increase of fire-resistance attributed to char formation compared with that of quercus variabilis.

Numerical Experiments Using Modified POM WAD with Computing Time Saving Technique (계산시간절약기법이 적용된 수정 POM WAD의 수치실험)

  • Park, Il Heum;Choi, Heung Bae
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.72-82
    • /
    • 2015
  • In order to effectively and economically apply the previous POM(Princeton Ocean Model) WAD(Wetting And Drying) to the coastal area, the POM WAD was modified such as the water elevation input of tidal harmonics in the open boundaries was included and a CTS(Computing Time Saving) technique was introduced to the model. The modified model was tested to the standing waves in the rectangular bay and the hydraulic experiments for the flow and heat diffusion in the 3D basin. The numerical results showed a good agreement with the analytical solutions of the standing waves and the observed values by the hydraulic experiments, respectively. And also when the modified model with the CTS technique was applied to Gwangyang Bay of Korea, the computing time was decreased by as much as 39.4%.

Natural Convection Heat Transfer in Rectangular Air Enclosures With Adiabatic and Isothermal Horizontal Boundary Conditions (단열 및 등온수평 경계조건을 갖는 직각 밀폐용기내 공기의 자연대류 열전달)

  • 이진호;김무현;모정하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.207-213
    • /
    • 1990
  • Natural convection heat transfer in rectangular air enclosure was studied interferometrically and numerically for the use of adiabatic and constant temperature horizontal boundary conditions. In the isothermal horizontal boundary case with the temperature difference ratio, .DELTA. $T_{v/}$.DELTA. $T_{H}$ .simeq. 1 temperature distribution in the enclosure is strongly stratified and the average Nusselt Number is higher than that of adiabatic horizontal boundary case.ase.

Modeling on the Condensation of a Stable Steam Jet Discharging into a Quenching Tank (응축탱크로 방출되는 안정된 증기제트 응축모델)

  • 김환열;하광순;배윤영;박종균;최상민
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.349-356
    • /
    • 2001
  • Phenomenon of direct contact condensation (DCC) heat transfer between steam and water is characterized by the transport of heat and mass through a moving steam/water interface. Since the DCC heat transfer provides some advantageous features in the viewpoint of enhanced heat transfer, it is widely applied to the diversified industries. This study proposes a simple condensation model on the stable steam jets discharging into a quenching tank with subcooled water from a single horizontal pipe for the prediction of the steam jet shapes. The model was derived from the mass, momentum and energy equations as well as thermal balance equation with condensing characteristics at the steam/water interface for the axi-symmetric coordinates. The extremely large heat transfer rate at the steam/water interface was reflected in the effective thermal conductivity estimated from the previous experimental results. The results were compared with the experimental ones. The predicted steam jet shape(i. e. radius and length) by the model was increasing as the steam mass flux and the pool temperature were increasing, which was similar to the trend observed in the experiment.

  • PDF

Experimental Study on Characteristics of Ammonia Conversion Rate of Urea Aqueous Solution in 250℃ Exhaust Pipe (250℃ 이하 배기관에서 우레아 수용액의 암모니아 전환율 특성에 관한 실험적 연구)

  • Ku, Kun Woo;Park, Hong Min;Hong, Jung Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.177-182
    • /
    • 2015
  • The NOx emissions from diesel engines and industrial boilers are a major cause of environmental pollution. The selective catalytic reduction of urea is an aftertreatment technology that is widely used for the reduction of NOx emissions. The objective of this study was to investigate the characteristics of the thermal decomposition of a urea aqueous solution using laboratory-scale experimental equipment under conditions similar to those of marine diesel engines. A 40 wt. urea aqueous solution was used in this study. It was found that the total conversion rate varied with the inflow gas conditions and flow rates of the urea aqueous solution. In addition, there were conversion rate differences between NH3 and HNCO. At inflow gas temperature conditions of $210^{\circ}C$ and $250^{\circ}C$, the $NH_3$ conversion rate was found to be higher than that of the HNCO, depending on the residence time.

Characteristics Diagnosis of Supersonic Air Plasma by 0.4 MW Class Segmented Type Arc Torch (0.4 MW급 분절형 아크 토치에 의한 초음속 공기 플라즈마의 특성 진단)

  • Kim, Min-Ho;Lee, Mi-Yeon;Choe, Chae-Hong;Kim, Jeong-Su;Seo, Jun-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.194-195
    • /
    • 2013
  • 초음속 공기 플라즈마 환경을 모사할 수 있는 0.4 MW급 Enhanced Huels형 초음속 공기 플라즈마 발생 장비가 2012년에 전북대학교에 설치 완료되었다. 초음속 공기 플라즈마 시험장비는 대기권으로 reentry 할 수 있는 비행체의 열차폐체 시험평가를 주목적으로 개발되었으며, 핵융합장치용 고온 내열체 소재개발에도 활용될 예정이다. 분절형 아크 플라즈마 토치는 전극부식에 의한 오염도를 적으면서 고출력의 안정적인 플라즈마를 발생시키며, 일반적인 직류 토치로는 얻을 수 없는 초고엔탈피 플라즈마 열유동을 얻을 수 있는 특징이 있다. 구축된 장비는 최대 직류 출력 1,200 kW의 DC 전원공급장치, 0.4 MW급의 분절형 아크 플라즈마 토치, ${\phi}1.5m{\times}2m$ 크기의 진공쳄버, 1 MW의 냉각 능력을 갖춘 디퓨저와 열교환기, 진공 용량 $100m^3$/min의 진공펌프 9대, 88 g/s의 공기유량에서 NOx를 50,000 ppm에서 100 ppm으로 저감할 수 있는 후처리 시스템, 4 bar 15 g/s의 공기를 공급할 수 있는 가스 공급장치, 30 bar 600 lpm의 저전도수와 4 bar 560 lpm의 일반수를 공급할 수 있는 냉각수 공급장치로 구성되어 있다. 초음속 공기 플라즈마의 발생 특성을 시험하기 위해 플라즈마 발생 조건으로 토치공급전력 350 kW와 410 kW, 토치 공기 공급 유량 16.3 g/s, 토치 내부압력 3.9~4.2 bar, 챔버압력 40 mbar으로 시험을 수행하였다. 발생된 플라즈마 상태를 진단하기 위해 속도는 쇄기 탐침기, 열유속은 Gardon 게이지, 엔탈피와 토치 효율은 토치의 공급전력과 냉각수에 의한 손실 전력으로 각각 측정하였다.

  • PDF