• Title/Summary/Keyword: 열확산률

Search Result 51, Processing Time 0.025 seconds

An Experimental Study for Characteristics Evaluation of Cement Mortar Using Infrared Thermography Technique (적외선 화상기법을 이용한 시멘트 모르타르 특성의 실험적 평가)

  • Kwon, Seung-Jun;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.53-59
    • /
    • 2010
  • Recently, NDTs (Non-Destructive Techniques) using infrared camera are widely studied for detection of damage and void in RC (reinforced concrete) structures and they are also considered as an effective techniques for maintenance of infrastructures. The temperature on concrete surface depends on material and thermal properties such as specific heat, thermal conductivity, and thermal diffusion coefficient. Different porosity on cement mortar due to different mixture proportions can show different heat behavior in cooling stage. The porosity can affect physical and durability properties like strength and chloride diffusion coefficient as well. In this paper, active thermography which uses flash for heat induction is utilized and thermal characteristics on surface are evaluated. Samples of cement mortar with W/C (water to cement ratio) of 0.55 and 0.65 are prepared and physical properties like porosity, compressive strength, and chloride diffusion coefficient are evaluated. Then infrared thermography technique is carried out in a constant room condition (temperature $20{\sim}22^{\circ}C$ and relative humidity 55-60%). The mortar samples with higher porosity shows higher residual temperature at the cooling stage and also shows reduced critical time which shows constant temperature due to back wall effect. Furthermore, simple equation for critical time of back wall effect is suggested with porosity and experimental constants. These characteristics indicate the applicability of infrared thermography as an NDT for quality assessment of cement based composite like concrete. Physical properties and thermal behavior in cement mortar with different porosity are analyzed in discussed in this paper.

Thermal Properties of Rocks in the Republic of Korea (한국의 암석 열물성)

  • Park, Jeong-Min;Kim, Hyoung-Chan;Lee, Young-Min;Shim, Byoung-Ohan;Song, Moo-Young
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.591-598
    • /
    • 2009
  • We made 2511 thermal property measurements on igneous, metamorphic, and sedimentary rock samples from Korea. The average thermal conductivities of igneous, metamorphic, and sedimentary rocks are 3.10 W/m-K, 3.76 W/m-K, and 3.54 W/m-K, respectively. Igneous rock can be classified into pluton, hypabyssal rock, and volconic rock; the average thermal conductivities of those rock types are 3.16 W/m-K, 3.26 W/m-K, and 2.77 W/m-K, respectively. Nonclastic sedimentary rock has higher thermal conductivity than clastic sedimentary rock. Thermal conductivity of Palezoic era rock is higher than Mesozoic era rock, because dominant mineral contents play an important role in the determination of thermal conductivity. Thermal conductivity of rocks is influenced by porosity. Therefore thermal conductivity of sedimentary rocks generally decreases with increasing porosity. Thermal conductivity and thermal diffusivity show linear correlation, its correlation coefficient of igneous, metamorphic, and sedimentary rocks are 0.775, 0.855, and 0.876, respectively.

Measurements of Thermal Diffusivity of Heavy Rolled Low Carbon Steel Plate With Laser Flash Technique (레이저 섬광법에 의한 압연된 저탄소강 판재의 열확산계수 측정)

  • 배신철;임동주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.157-171
    • /
    • 1990
  • The heat transfer problem associated with pulse technique for measuring thermal diffusivity was solved by means of Green function. The obtained general solution was discussed so as to apply for all possible cases; kinds of boundary condition and heat source, irradiation positions of heat pulse, radius of heat pulse, one-and two-dimensional heat flow, finite pulse time effects and radiation heat loss systems. Experimentally, the laser flash lamp was used as heat source for measuring thermal diffusivity of low carbon, aluminium chilled steel plate, which was heavily rolled in order to measure the variation of thermal diffusivity in the temperature range from room temperature through 500.deg. C. The derived results are (1) materials produced from same furnace showed a somewhat different thermal diffusivity values. (2) the thermal diffusivity value of rolled material was smaller than unrolled material and the difference decreased as increasing temperature. (3) the thermal diffusivity value of an annealed and temper rolled material was larger than the value of a cold rolled material, even thought smaller than unrolled material. (4) In case of heavy rolled material, there was no consistent relationships between the thermal diffusivity and the reduction in thickness.

Forecasting Unemployment Rate using Social Media Information (소셜 미디어 정보를 이용한 실업률 예측)

  • Na, Jonghwa;Kim, Eun-Sub
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.6
    • /
    • pp.95-101
    • /
    • 2013
  • Social media has many advantages. It can gain latest information with real time, be spread rapidly, easily be reproduced and distributed regardless of its form. These advantages can result in real time predictions using the latest information, which is possible due to the increase in social demand for more quick and accurate economic variable predictions. In this paper we adopted ARIMAX and ECM model to predict the unemployment rate and as a social information we used the Google Index provided by Google Trend. Also we used News Index as a domestic social information. The process of fitting statistical model considered in this paper can be adopted to predict various socio/economic indices as well as unemployment rate.

A Comparison of Laser Flash and the Divided-bar Methods of Measuring Thermal Conductivity of Rocks (암석 열전도도 측정을 위한 Laser Flash Method와 Divided-bar Method 비교)

  • Oh, Jae-Ho;Kim, Hyoung-Chan;Park, Jeong-Min
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.387-397
    • /
    • 2011
  • In this study, we conducted the study of the merits and demerits of the laser flash and the divided-bar methods for measuring the thermal conductivity of rocks and investigated applicability of the divided-bar apparatus which was developed by KIGAM. The laser flash method can measure thermal diffusivity, specific heat capacity, and thermal conductivity of rocks with even small thickness (< ~3 mm) in the high temperature range($25-200^{\circ}C$) in non-contact mode. For the laser flash method, samples must be uniform and homogeneous. In the case of the divided-bar method, the apparatus measures only thermal conductivity of rock samples at the room temperature. We measured thermal conductivities of 12 rock samples with low density and high porosity using two methods. In the laser flash method, there exist potential errors caused by the effect of pulse dispersion and reflection by various minerals and porosity in rock samples; the difference in thermal conductivity values measured on the front surface and the opposite surface ranges from 0.001 to 0.140 W/mK with the standard deviation of 0.003~0.089 W/mK, which seems to be caused by heterogeneity of rock samples. On the contrary, the divided-bar apparatus shows stable thermal conductivity measurements and relatively small measurement errors; the difference in thermal conductivity values, just as we applied to the laser frash method, is 0.001~0.016 W/mK with the standard deviation 0.001~0.034 W/mK. In turn, the divided-bar method can be applied to more thick samples that are more representative of bulk thermal conductivity.

Evaluation of Durability Performance of Fly Ash Blended Concrete due to Fly Ash Replacement with Tire Derived Fuel Ash (타이어 고무 애쉬 치환에 따른 플라이애쉬 혼입 콘크리트의 내구성능 성능 평가)

  • Kwon, Seung-Jun;Yoon, Yong-Sik;Park, Sang-Min;Kim, Hyeok-Jung
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.647-653
    • /
    • 2016
  • In the paper, durability performance in FA (Fly Ash) blended concrete is evaluated considering replacement of FA with TDFA (Tire Derived Fuel Ash) from 3.0% to 12%. TDFA is a byproduct from combustion process in thermal power plant, where chopped rubber is mixed for boiling efficiency. This is the 1st study on application of TDFA to concrete as mineral admixture. For the work, concrete samples containing 0.5 of w/b (water to binder) ratio and 20% replacement ratio of FA are prepared. With replacing FA with TDFA to 12%, durability performance is evaluated regarding compressive strength, carbonation, chloride diffusion, and porosity. The results of compressive strength, carbonation, and porosity tests show reasonable improvement in durability performance to 12% replacement of TDFA. In particular, clear decreasing diffusion coefficient is observed with increasing TDFA replacement due to its packing effect. Concrete containing TDFA can be effective for durability improvement when workability is satisfied in mixing stage.

Measurements of the Heat Release Rate and Fire Growth Rate of Combustibles for the Performance-Based Design - Focusing on the Plastic Fire of Commercial Building (성능위주설계를 위한 가연물의 열발생률 및 화재성장률 측정 - 판매시설의 플라스틱 화재를 중심으로 -)

  • Jang, Hyo-Yeon;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.55-62
    • /
    • 2018
  • To improve the prediction result with enhanced reliability of domestic Performance-Based Design (PBD), actual scale fire tests were carried out on products made of plastics from sales facility combustibles. The commercial buildings were separated into single and multiple combustibles for the experimentation of fire spread caused by the sales shelves where the various combustible materials are displayed. A according to the maximum heat release rate, exposed area and weight of the combustible material, the results revealed a linear relationship of as 93% and 89%. In addition, analysis of the gas concentrations for various combustibles showed that $CO_2$ has a linear relationship, whereas the CO concentration indicated exponential function. These results can be applied to reliable fire source information in PBD of plastic fire source in commercial buildings. This may be applied as fire source information representative of a plastic fire in commercial buildings through additional experiment using the area of the shelf in actual commercial buildings.

A Study on the Fire Characteristics of Aluminum Composite Panel by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 알루미늄 복합패널 외장재의 연소특성에 관한 연구)

  • Yun, Jung-Eun;Min, Se-Hong;Kim, Mi-Suck;Choi, Sung-Bok
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.89-96
    • /
    • 2010
  • In this research, exterior material combustion experiment was really tested to evaluate fire risks of aluminium complex panel which is used a lot for building exterior material. As a result, We saw fast fire spreading of aluminium complex panel. The reason is polyethylene in aluminum complex panel combust spreading fast fire flame vertically. In this test, the highest heat release rate of aluminum complex panel was 1,144 kW and surface temperature which is measured by thermocouple went up to more than $903.3^{\circ}C$, that temperature is quite a higher than $660^{\circ}C$ which is aluminum melting temperature. So, fire of aluminum complex panel can be evaluated to give us severe damage both by fast fire spreading vertically and by fire spreading through openings internally. These results from real experiment will be able to use to predict fire spreading of aluminum complex panel by comparing to modeling materialization of aluminum complex panel in the future.

Error Resilience Coding Techniques for Mobile Videotelephony (모바일 화상통신을 위한 오류강인 부호화 기법)

  • Suh, Jae-Won
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.303-310
    • /
    • 2007
  • Compressed video bitstreams are intended for real-time transmission over communication networks. Because video compression algorithms eliminate the temporal, spatial, and statistical redundancies, the coded video bitstreams are very sensitive to transmission errors. We propose an error resilient video coding technique to limit the effect of error propagation in low bit-rate video coding. The success of error resilient coding techniques relies on how accurately the transmission errors can be detected. To detect the transmission error, we propose a very simple error detection technique based on data hiding Next, we conceal the corrupted MB data using intra MB refresh and motion compensation with the estimated motion vector and compare the simulation results. This method will be useful in video communication in error Prone environment such as WCDMA networks.

A Study on Renewable Energy Financing Support Program (신재생에너지 융자지원제도 고찰)

  • Park, Joo-Young;Kim, Jin-Soo;Lee, You-Ah;Heo, Eun-Nyeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.232-234
    • /
    • 2009
  • 신재생에너지 보급 확산을 위해서 정부에서는 2009년부터 2030년까지의 시평을 가진 '제3차 신재생에너지 기술개발 및 이용 보급' 기본계획을 수립하고, 이의 달성을 위하여 예산투자와 함께 기술개발 지원, 보급 보조 및 융자, 발전차액지원제도, 그린홈 100만호 보급사업 등을 다각적으로 추진하고 있다. 이러한 보급지원제도의 하위제도로써의 융자지원제도는 신재생에너지 설치자 및 생산자를 대상으로 장기저리의 융자지원을 해주는 제도이다. 이를 통해 초기 투자비를 경감, 사업적 경제성을 확보하여 신재생에너지설비 및 관련 산업을 보급, 육성하고자 하는 것이다. 융자지원을 위한 금리는 기준금리(국고채 3년물 수익률)에 연동하여 분기별로 조정되고, 시설자금, 생산자금, 운전자금으로 분류하여 태양열, 태양광, 바이오, 폐기물, 수력, 지열, LFG, 풍력, 연료전지 등의 분야에 지원한다. 따라서 본 연구에서는 융자지원제도 현황을 고찰하고, 기준금리의 변동에 따른 융자지원 금리의 변동을 함께 살펴보았다. 각 에너지원별 지원에 어떠한 영향을 주는지 알아보았다.

  • PDF