• Title/Summary/Keyword: 열화조건

Search Result 598, Processing Time 0.031 seconds

Visibility of the Thermal Infrared Camera under Non-Visibility Environments (비가시 환경에서의 적외선 열화상 카메라의 가시도)

  • Cho, Jai Wan;Baik, Seong Hoon;Choi, Young Soo;Jeong, Kyung Min
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1315-1316
    • /
    • 2015
  • 본 논문에서는 원자력발전소 중대 사고를 모사한 비가시 환경에서 적외선 열화상카메라의 관측성능 (가시도)을 정량적으로 평가하고자 하였다. 이를 위해 세계기상기구의 가시도 정의를 이용하여 가시도를 측정하였으며, 측정된 가시도 조건에서 적외선 열화상카메라의 관측성능을 평가하였다.

  • PDF

Effect of Membrane Degradation on the Electrode Degradation in PEMFC (PEMFC에서 막 열화가 전극 열화에 미치는 영향)

  • Song, Jinhoon;Jeong, Jaejin;Jeong, Jaehyeun;Kim, Saehoon;Ahn, Byungki;Ko, Jaijoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.3
    • /
    • pp.325-329
    • /
    • 2013
  • The membrane and electrode were degraded coincidentally at real PEMFC(Proton Exchange Membrane Fuel Cells) operation condition. But the interaction membrane degradation between electrode degradation has not been studied. The effect of membrane degradation on electrode degradation was studied in this work. We compared electrode degradation after membrane degradation and electrode degradation without membrane degradation. I-V performance, hydrogen crossover current, impedance and TEM were measured after and before degradation of MEA. Membrane degradation enhanced hydrogen crossover, and then Pt particle growth rate was reduced. Increase of hydrogen crossover by membrane degradation reduced the electrode degradation rate.

The Effect of Oxygen Absorbent on Aged Characteristics of Hanji during Biological Artificial Aging by Aspergillus versicolor and Penicillium polonicum (산소흡수제 처리가 Aspergillus versicolor와 Penicillium polonicum에 의한 한지의 생물열화 특성에 미치는 효과)

  • Jeong, Hye Young;Choi, Kyoung-Hwa;Park, Ji Hee;Seo, Jin Ho
    • 보존과학연구
    • /
    • s.32
    • /
    • pp.137-153
    • /
    • 2011
  • Paper cultural heritages in museums and libraries are deteriorated by many biological factors like as fungi, insects, bacteria and rodents and get irreversibly damaged. Especially, paper components like as cellulose, hemicellulose, lignin, pectins, tannins, proteins and mineral additives are good nourishment for microorganism. Through some studies on fungi causing the aging of paper materials, Aspergilli (about 30%) and Penicilli (more than 30%) are the most common among 300 different kinds of microorganism that caused the biological aging of paper cultural heritages in museums and libraries. At present, various treatments are attempted to control the biodeterioration by these fungi. Especially, it is focused on the control of environmental factors such as humidity, temperature and oxygen. In this study, the oxygen absorbent was used to control oxygen, one of the these favorable conditions during the biological aging of Hanji by Aspergillus versicolor and Penicillium polonicum and then the effect on prevention in aging by this treatment was investigated. In result, the oxygen absorbent treatment had the good effect on prevention in aging during the biological aging by two species of fungi.

  • PDF

A Study on Electrochemical Anodic Polarization Behavior for Material Degradation Evaluation of High Temperature Structural Components (고온설비부재의 재질열화도 평가를 위한 전기화학적 양극분극거동에 관한 연구)

  • Yu, Hyo-Seon;Kim, Yeon-Jik;Jeong, Se-Hui
    • Korean Journal of Materials Research
    • /
    • v.7 no.9
    • /
    • pp.717-722
    • /
    • 1997
  • 노후화된 고온설비의 안정성 및 효율적인 운전조건을 확보하고, 고온부재의 취성파괴 방지를 위해서는 재질열화의 정량적 평가는 매우 중요하다. 그러나 현장실기에서 기계적 성질의 평가를 위한 대량의 시험편 채취는 거의 불가능하다. 따라서, 실기부재의 강도에 영향을 미치지 않는 범위에서 플랜트 구조물의 재질열화 평가를 비파괴적으로 검출 평가할 수 있는 새로운 시험방법들의 개발이 요구된다. 본 연구에서는 화력설비 부재의 다양한 탄소강을 대상으로 재질열화도 평가를 위한 전기화학적 양극분극시험법의 적용 가능성을 조사하였다. 또한 양극분극시험에 의한 재질열화평가 유효성을 조사하기 위해 전기화학적 시험결과를 입계부식시험결과와 비교.검토해 보았다.

  • PDF

Reliability Evaluation of the WSW Device for Hot-carrier Immunity (핫-캐리어 내성을 갖는 WSW 소자의 신뢰성 평가)

  • 김현호;장인갑
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.1
    • /
    • pp.9-15
    • /
    • 2004
  • New WSW(Wrap Side Wall) is proposed to decrease junction electric field in this paper. WSW process is fabricated after first gate etch, followed NM1 ion implantation and deposition & etch nitride layer. New WSW structure has buffer layer to decrease electric field. Also we compared the hot carrier characteristics of WSW and conventional. Also, we design a test pattern including pulse generator, level shifter and frequency divider, so that we can evaluate AC hot carrier degradation on-chip. It came to light that the universality of the hot carrier degradation between DC and AC stress condition exists, which indicates that the device degradation comes from the same physical mechanism for both AC and DC stress. From this universality, AC lifetime under circuit operation condition can be estimated from DC hot carrier degradation characteristics.

  • PDF

Performance Evaluation of Image Saturation of Thermal Imaging Camera for the Fire Service (화재용 열화상 카메라의 영상포화특성 평가)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.69-74
    • /
    • 2012
  • Thermal imaging technology based on IR sensor with high transmittance through the fire smoke is considered as one of the advanced technology for the fire service. The present study has been performed to investigate the image saturation characteristics with thermal condition of target and background and evaluate the performance of image quality based on the contrast transfer function (CTF). For the present testing conditions, TIC using BST sensor did not show the image saturation and the image quality based on the CTF was proportional to the temperature difference between target and background. This study can be utilized as preliminary study to improve reliability and technical development of TIC.

A Study on the Application of Dobak-glue for Fixation Painting Layer of Earthen Mural (토벽화 채색층 고착처리를 위한 도박풀 적용 연구)

  • Kim, Seol Hui;Han, Kyeong Soon;Lee, Hwa Soo
    • Journal of Conservation Science
    • /
    • v.33 no.6
    • /
    • pp.553-564
    • /
    • 2017
  • This report compared and analyzed the degree of surface change and results of a deterioration experiment to assess the possibility of using Dobak glue as an adhesive in the fossilizing treatment of the paint layer in earthen mural paintings. The weathering experiments were performed with a color-difference meter (CR-400, MINOLTA). After the experiment, Cinnabar 3% specimens, which exhibited diverse changes in the durability test, were additionally tested with a reflection-transmission device (CARY-5000, AGILENT). Post UV degradation, most of the Dobak-glue samples exhibited lesser color change than animal-glue samples, and after moisture absorption and drying, the 0.5% and 3% Dobak samples displayed a lower degree of change in the value of color difference. Furthermore, results of the reflection-transmission test after deterioration indicated that Dobak glue presented a lesser color change than animal glue. Therefore, if Dobak glue is used as a consolidating agent, discoloration on account of degradation is minimal.

Application Angle of Defects Detection in the Pipe Using Lock-in Infrared Thermography (위상잠금 적외선 열화상 기법을 이용한 각도별 원전 감육 배관의 결함 검출)

  • Yun, Kyung-Won;Go, Gyeong-Uk;Kim, Jin-Weon;Jung, Hyun-Chul;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.323-329
    • /
    • 2013
  • This perform research of angle rated defect detection conditions and nuclear power plant piping defect detection by lock-In infrared thermography technique. Defects were processed according to change for wall-thinning length, Circumference orientation angle and wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and target pipe's distance fixed 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. Reliability of lock-In infrared thermography data is higher than Infrared thermography data. This through research, Shape of angle rated defect is identified industry place. It help various angles defect detection in the nuclear power plant in operation.

Analysis of the ESD-Induced Degradation Behavior of Oxide VCSELs Using an Equivalent Circuit Model (ESD에 따른 산화형 VCSEL 열화 과정의 등가회로 모델을 이용한 분석)

  • Kim, Tae-Yong;Kim, Sang-Bae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.6-21
    • /
    • 2008
  • We have investigated the effect of the forward and reverse ESD pulse accumulation on the development of the oxide VCSEL's electrical and optical characteristics. The forward ESD-induced degradation is complicated, showing three degradation phases with increasing ESD voltage while the reverse ESD-induced degradation is divided by a sudden distinctive change in elecorl-optical characteristics. By comparing the measured L-I-V characteristics and their derivatives with the fitted characteristics using an equivalent circuit model as well as the large signal circuit model, the development of the oxide VCSEL's electro-optical characteristics under forward and reverse ESD conditions has been fully understood.

Damage Characteristics of Korean Traditional Textiles by Formaldehyde (포름알데히드에 의한 전통직물의 손상 특성)

  • Kim, Myoung Nam;Lim, Bo A;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.30 no.4
    • /
    • pp.353-364
    • /
    • 2014
  • Formaldehyde(HCHO) may have a damage effect on Korean traditional textiles, because concentration is high and occurrence frequency is frequent at the exhibition room and storage area. Total 20 specimens were prepared using 4 different materials (silk, cotton, ramie, hemp) after dyeing with 5 colors (undyed, red, yellow, blue, black). The specimens were exposed to HCHO gas in the test chamber. The gas acceleration test was conducted to identify the deterioration of Korean traditional textiles according to HCHO concentration(0.5, 1, 10, 100, 500ppm), to temperature-humidity condition at HCHO 500ppm, and deterioration conditions at HCHO 500ppm. Optical, chemical, and physical evaluation was carried out after the exposure. The results, color difference, grey scale rating, formate($HCO_2{^-}$) of some textiles increased at 500ppm, while pH decreased at 500ppm. Also, color difference, grey scale rating, formate($HCO_2{^-}$) of some textiles increased double damage at high temperatures & humidity, high humidity condition. But, damages of accelerated degradation textiles were slight, because of degradation degree and degradation products. The results suggest that determined the damage to the korean traditional textile, damage level, damage-weighted condition, damage to accelerated degradation textiles. In addition, formaldehyde damaged to yellowing of red textiles, bleaching of accelerated degradation textiles, formic acid damaged to bleaching of total 20 specimens.