Abstract

This perform research of angle rated defect detection conditions and nuclear power plant piping defect detection by lock-In infrared thermography technique. Defects were processed according to change for wall-thinning length, Circumference orientation angle and wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and target pipe's distance fixed 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. Reliability of lock-In infrared thermography data is higher than Infrared thermography data. This through research, Shape of angle rated defect is identified industry place. It help various angles defect detection in the nuclear power plant in operation.

위상잠금 적외선 열화상 기법을 이용하여 원전 배관의 결함 검출 및 각도별 결함 검출 조건에 관한 연구를 수행하였다. 결함의 가공은 감육 길이, 원주방향 각도, 감육 깊이를 변화시켜 결함조건을 가공하였다. 사용된 장비는 적외선 열화상 카메라와 1 kW용량의 halogen lamp 2개를 사용하였으며, halogen lamp와 대상 배관과의 거리는 2 m로 고정시켜 실험을 수행하였다. 실험결과의 분석을 위하여 온도분포, 위상 데이터를 확보하고, 이를 분석하여 결함 길이를 측정하였다. 이 연구를 통해 각도별로 나타나는 감육 결함의 검출 형태를 파악함으로서 실제 발전소의 배관에 나타나는 다양한 각도의 결함의 분석이 가능하다. 적외선 열화상 데이터보다 위상잠금 적외선 열화상 데이터가 측정 결과의 신뢰도가 높았다.

Keywords

References

  1. Y. M. Cheong, "Experimental evidence and analysis of a mode conversion of guided wave using magnetostrictive strip transducer," Journal of the Korean Society for Nondestructive Testing, Vol. 29, No. 2, pp. 93-97 (2009)
  2. M. Y. Choi, "The utilization of nondestructive testing and defects diagnosis using infrared thermography," Journal of the Korean Society for Nondestructive Testing, Vol. 24, No. 5, pp. 525-531 (2004)
  3. Korea Hydro & Nuclear Power Co., "Management program for Thinned Pipe in NPP Secondary System," Final Report - 00NJ12 (2003)
  4. S. H. Lee, T. R. Kim, S. C. Jeon and K. M. Hwang, "Thinned pipe management program of Korean NPPs," Transaction of SMiRT-17, Paper #O04-2, Prague, Czech Repblic, Aug. 17-23 (2003)
  5. IAEA, "Development of protocols for corrosion and deposits evaluation in pipes by radiography," IAEA-TECDOC-1445 (2005)
  6. T. Knook, M. Persoz, S. Trevin, S. Friol, M. Moutrille and L. Dejoux, "Pipe wall thinning management at Electricite de France (EDF)," E-Journal of the Advanced Maintanance, Vol. 2, pp. 1-13 (2010)
  7. K. J. Lee, H. S. Jang, H. C. Jung and K. S. Kim, "Quantitative out-of-plane deformation measurement of pressure vessel with the defect using shearography," Journal of the Korean Society for Precision Engineering, Vol. 23, No. 10, pp. 36-42 (2006)
  8. X. P. V. Maldague, "Trends in Optical Nondestructive Testing and Inspection," P. K. Rastogi, D. Ibaudi, Editors Elsevier Science, Switzerland (2000)
  9. K. S. Kim, H. J. Jung, C. J. Park, D. S. Kim, D. W. Jung and H. S. Jang, "A study on measuring the temperature and revising the resuit when measuring the temperature of NPP pipes using infrared thermography," Journal of the Korean Society for Nondestructive Testing, Vol. 29, No. 5, pp. 421-426 (2009)