• Title/Summary/Keyword: 열형광

Search Result 323, Processing Time 0.034 seconds

On the Dynamic Characteristics of Cell Contact by Analyzing TIRE Images (전반사 형광 이미지 분석을 통한 세포 부착점의 운동 특성에 관한 연구)

  • Lee, Yong-Ku;Jin, Song-Wan;Koo, Sang-Mo;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.3 s.258
    • /
    • pp.380-387
    • /
    • 2007
  • We carried out an image analysis of living cells forming their contacts at the bottom of the cell culturing substrate. In order to visualize the contact area selectively, we adopted total-internal-reflection-fluorescence (TIRF) method, which can illuminate the specimen volume within only several hundred nano-meters above the substrate. From the fluorescent intensity of the TRF image, we could calculate the distance of the cell surface from the substrate. As a result, we visualized the origin of cell contacts, their movements, and the change of cell-contact type from the close-contact into focal-contact with information of its vertical displacement representing the temporal evolution process of the three-dimensional cell-surface-profile near the contact area during this metamorphosis.

EL 기술 개요

  • Kim, Seong-Jin
    • Electrical & Electronic Materials
    • /
    • v.21 no.1
    • /
    • pp.11-20
    • /
    • 2008
  • EL (Electro-Luminescence)란 전계발광소자로서 반도체, 주로 형광체에 전계를 인가할 때 아무런 열 발생 없이 발광하는 현상을 말한다. EL 발광현상은 형광물질에 고전기 장이 인가되었을 때, 고전기장에 의해 전자를 가속되고 가속된 전자가 발광중심이라 불리는 Light-emitting Center의 전자를 충돌 여기 시키고 이렇게 여기 된 전자가 다시 바닥상태로 완화될 때, 빛이 발생하는 현상을 일컫는다. 이러한 효과를 이용하여 여러 가지 디바이스에 응용이 되고 있고, 특히 TN, STN LCD의 백라이트로서 각광을 받았으나, 휴대폰 LCD의 컬러화로 인해 그 수요가 급격히 감소하였으나, 현재는 휴대폰의 키패드의 백 라이트로서 LED와 경쟁을 하고 있다. EL만이 가지는 여러 가지 장점으로 인해 광고용 등에 특히 많이 응용이 되고 있다. 또한 캐나다의 iFire사(社)와 같은 회사에서는 무기 EL을 이용하여 디스플레이로서도 활용을 하고 있어 그 응용 가능성이 매우 크다.

  • PDF

Design of a AC driver with constant current and negative temperature resistance for a LED lamp (정전류와 부 열저항 특성을 갖는 AC Direct Driver를 이용한 LED 형광등 개발)

  • Kim, Hyun-jo;Son, Kyung-min;Kim, Min;Kim, Gwan-Hyung;Byun, Gi-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.382-384
    • /
    • 2013
  • LED is much brighter than the traditional incandescent, and low power consumption. Development and commercialization of LED fluorescent lamp is made in order to improve efficient fluorescent lamps with this existing and environmental problems. Because, unlike fluorescent lamps, it is not possible to directly use AC power to the unidirectional element having a polarity, LED requires a power supply. The power supply function is lowered as compared with the fluorescent lamp common in terms of maintenance costs because of the high price large. In this study, we constructed a circuit that can be controlled with a constant current in order to eliminate a phenomenon that brightness of the light which rectifies the AC power supply easy to place in the power supply due to the current change due to the voltage fluctuation is changed, in maintenance, I would like to propose how to develop a device which can be easily replaced less expensive composed of interchangeable modules of Plug in / out method to distinguish the LED module this.

  • PDF

Synthesis and luminescent properties of $Er^{3+}$ doped $CaZrO_3$ long persistent phosphors ($Er^{3+}$를 첨가한 $CaZrO_3$ 축광성 형광체의 합성 및 발광 특성 분석)

  • Park, Byeong-Seok;Choi, Jong-Koen
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Novel long persistent phosphors of $CaZrO_3:Er^{3+}$ have been synthesized by traditional solid state reaction method. The long persistent phosphor crystalline particles were characterized by the X-ray diffraction (XRD), photoluminescence spectrophotometer, thermoluminescence (TL) and luminance meter. The results reveal that the samples are composed of single $CaZrO_3$ phase. The broadband emission spectra of 446 nm peak and 550 nm peak was revealed by synthesized at high temperature in $N_2$ gas. Green long persistent phosphors have been observed in the sys_em for over 6 h after UV irradiation (254 nm). The main emission peak was ascribed to $Er^{3+}$ ions transition from $^5D_{5/2}{\rightarrow}^4F_{9/2},\;^2H_{12/2},\;^4S_{3/2}{\rightarrow}^4I_{13/2}\;and\;^2G_{9/2}{\rightarrow}^4I_{13/2}$, and the afterglow may be ascribed to the suitable trap centers in the $CaZrO_3$ host lattice.

A study on the effects of scattering dose on eyes and thyroid for panoramagraphy - Focus on TLD and PLD - (파노라마 촬영시 눈과 갑상선에 미치는 표면선량에 관한 연구 - TLD, PLD 중심으로 -)

  • Dong, Kyung-Rae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1118-1123
    • /
    • 2009
  • Ten hospitals from the Gwangju area were used to examine shallow dose to eyes and thyroid from panoramagraphy. Thermoluminescent dosimeter (TLD) and Photoluminescent dosimeter (PLD) were used as measurement devices at each hospital. ICRP 60 and ICRP 73 set standards for acceptability for eyes at 15mSv and thyroid at 1mSv per year. Left eye measures with TLD and PLD resulted in 0.19mSv and 0.24mSv respectively. Right eye measures with TLD and PLD resulted in 0.23mSv and 0.25mSv respectively. Thyroid measures with TLD and PLD resulted in 0.08mSv and 0.25mSv respectively with both measures not exceeding standards for acceptance. There was a significant difference in comparing the left eye and thyroid for TLD and PLD (p<0.01). There was no significant difference with the right eye (p>0.05). The absorbed dose measurements for eyes and thyroid using TLD and PLD in regards to panorama devices at each hospital were within the ICRP 60 recommendations; however, with the possibility of stochastic effect, all dose levels were taken into consideration.

  • PDF

Preparation and Luminescence Optimization of CeO2:Er/Yb Phosphor Prepared by Spray Pyrolysis (분무열분해법으로 CeO2:Er/Yb 형광체 제조 및 발광특성 최적화)

  • Jung, Kyeong Youl;Park, Jea Hoon;Song, Shin Ae
    • Applied Chemistry for Engineering
    • /
    • v.26 no.3
    • /
    • pp.319-325
    • /
    • 2015
  • Submicron-sized $CeO_2:Er^{3+}/Yb^{3+}$ upconversion phosphor particles were synthesized by spray pyrolysis, and their luminescent properties were characterized by changing the concentration of $Er^{3+}$ and $Yb^{3+}$. $CeO_2:Er^{3+}/Yb^{3+}$ showed an intense green and red emission due to the $^4S_{3/2}$ or $^2H_{11/2}{\rightarrow}^4I_{15/2}$ and $^4F_{9/2}{\rightarrow}^4I_{15/2}$ transition of $Er^{3+}$ ions, respectively. In terms of the emission intensity, the optimal concentrations of Er and Yb were 1.0 % and 2.0%, respectively, and the concentration quenching was found to occur via the dipole-dipole interaction. Upconversion mechanism was discussed by using the dependency of emission intensities on pumping powers and considering the dominant depletion processes of intermediate energy levels for the red and green emission with changing the $Er^{3+}$ concentration. An energy transfer from $Yb^{3+}$ to $Er^{3+}$ in $CeO_2$ host was mainly involved in ground-state absorption (GSA), and non-radiative relaxation from $^4I_{11/2}$ to $^4I_{13/2}$ of $Er^{3+}$ was accelerated by the $Yb^{3+}$ co-doping. As a result, the $Yb^{3+}$ co-doping led to greatly enhance the upconversion intensity with increasing ratios of the red to green emission. Finally, it is revealed that the upconversion emission is achieved by two photon processes in which the linear decay dominates the depletion of intermediate energy levels for green and red emissions for $CeO_2:Er^{3+}/Yb^{3+}$ phosphor.

The Response Correction Function of TL Dosimeter for Shallow Dose Assessment in Tl-204 Beta Fields (Tl-204 베타선장에서의 피부선량평가를 위한 열형광선량계의 베타보정함수)

  • Lee, Sang-Yoon;Kim, Jang-Lyul;Seo, Kyung-Won
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.381-388
    • /
    • 1994
  • Recently, the American National Standards Institute (ANSI) had made some changes in the radiation sources specified from those in the original performance test criteria ANSI N13. 11-1983. In case or beta category, in addition to the high-energy $^{90}$ Sr/$^{90}$ Y beta source, the $^{204}$ Tl source was added because many workplaces have significant levels of lower energy betas. In this study, the performance or the Teledyne PB-3 personnel dosimetry system in the fields of $^{204}$ Tl and $^{90}$ Sr/ $^{90}$ Y beta was investigated using the PTB beta secondary standard sources. The new beta correction function of PB-3 personnel dosimetry system for $^{204}$ Tl beta was also developed in this response experiment. The results show that the Teledyne PB-3 personnel dosimetry system is very effective for $^{90}$ Sr/ $^{90}$ Y beta dose assessment. In case of $^{204}$ Tl beta radiation, however, the results of simple performance test indicated that the use of beta correction factor(=2.088) which was recommanded by manufacturer may result in unexpectable overestimation of delivered dose by about 60%, while the use of developed beta correction function could measure the delivered doses in errors of 15%.

  • PDF

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

Analysis of the Respiratory Motion Effects on Dose Distribution Using TLD Phantom (열형광선량계용 팬톰을 이용한 호흡 움직임에 따른 선량분포의 평가)

  • Hong, Ju-Young;Kim, Yon-Lae;Rah, Jeong-Eun;Chung, Jin-Beom;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.187-191
    • /
    • 2006
  • The purpose of this study was to measure the dose distribution from the moving phantom for the respiratory motion. The phantom for TLD measurement was designed and built for this study based on the multiple plates for placing TLD and film. The TLDs may be inserted at 3 mm intervals in each TLD plate. For the measurements, TLD plate was inserted into the phantom at 1.5 cm ($d_{max}$) depth, and phantom was allowed to move in SI directions in the range of 1 to 2 cm with 0.5 cm interval for 6 MV X-ray beams. Penumbra and FWHM were measured at both moving state and compared stationary. It was found that penumbra increased 0.71 cm at stationary and 2.10 cm at moving state in 2 cm movement, and that FWHM are 7.52 cm for stationary state and 7.02 cm for moving state (2 cm movement). In this study, film was used to compared with TLD results of measurements and simitar results were observed. Therefore, it is expected that TLD moving phantom may be useful for the treatment of tumors that move due to the respiratory motion.

  • PDF

A Feasibility Study on the Lens of Eye Dose Assessment Using the System of Multi-Element TLD (다중소자 열형광선량계에 의한 수정체 등가선량 평가의 적정성 연구)

  • Lee, Na-Rae;Han, Seung-Jae;Lee, Byung-Il;Cho, Kun-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.96-102
    • /
    • 2012
  • International Commission on Radiological Protection (ICRP) has revised its recommendations concerning the tissue reaction to ionizing radiation in accordance with consideration of the detriment arising from non-cancer effects of radiation on health based on recent epidemiological basis. Particularly, for the lens of the eye, the threshold in absorbed dose revised to be 0.5 Gy, for occupational exposure in planned exposure situation the commission recommended "An equivalent dose limit for the lens of the eye of 20 mSv in a year, averaged over defined periods of 5 years, with no single year exceeding 50 mSv." To monitor the radiation exposure of radiation worker, TLD is typically provided and the lens of eye dose can be assessed by run of dose calculation algorithm with TL element response data. This study is to assess equivalent dose of the lens of eye using the Harshaw TLD system and its two different dose calculation algorithms. The result provides the Harshaw TLD system showed the assessment of the lens of eye dose with 48.84% error range.