• Title/Summary/Keyword: 연기검출

Search Result 84, Processing Time 0.032 seconds

Monitoring of Toxicants Affecting Metamorphosis of Silkworm in Mulberry Leaves (뽕잎 및 대기 중 누에영향물질 모니터링 및 독성조사)

  • Park, Kyung-Hun;Park, Yeon-Ki;Lee, Hee-Dong;Park, Byung-Jun;Joo, Jin-Bok;Sohn, Bong-Hee;Kang, Pil-Don;Kim, Mi-Ja;Seong, Su-Il
    • Journal of Sericultural and Entomological Science
    • /
    • v.46 no.2
    • /
    • pp.58-64
    • /
    • 2004
  • The current study was performed to clarify the pupation disorder symptoms in silkworm which herbicide, molinate has been regarded as a causal origin. Molinate residues in mulberry leaves was monitored in major rearing area of silkworm; Yeacheon, Sangju and Namwon. Detected range of the molinate in mulberry leaves was 0.002 to 0.013 mg/kg and detection frequency was 30.0 to 81.8%. Molinate concentration in the air of mulberry tree growing area was $0.004\;{\mu}g/m^3$. Water diluted solution of molinate at the concentration of 1, 10, 100 mg/l gave no abnormal symptoms in silkworm irrespective of spraying to silkworm or spiking to diet. Exposing the silkworm to the air containing 250, 2,500, and $10,000\;{\mu}g/m^3$ also revealed no abnormal symptom. These results illustrated that the abnormal growth of silkworm encountered in the field was not caused by pesticide contamination.

Study on the direction detection based on audible and non-audible signals using smart devices (스마트 디바이스를 활용한 가청, 비가청 신호 기반 피난방향 탐지 기법 연구)

  • Hyun, Byeongchun;Yun, Younguk;Park, Yohan;Kim, Youngok
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.1
    • /
    • pp.51-58
    • /
    • 2017
  • This paper proposes a direction estimation scheme with directional speaker and smart device for evacuation guidance. When there is worst disaster environment filled with smoke and noisy sound, evacuee can not get any information about evacuation routes. The proposed scheme can be used for detecting evacuation routes with audible and inaudible signal from directional speaker. At this point, evacuee can get evacuee guidance by using smartphone application that the proposed scheme is applied. The performance of the proposed scheme is evaluated by experiment with three different types of smart devices in large indoor environment. The purpose of experiment is to detect the direction of transmitted signal from directional speaker. Therefore, The experiment is conducted by analyzing the strength of transmitted signal by distance. The experimental results show that even if the smart device is located up to 20m away from the speaker, it is possible to detect the sending direction of the signal. We confirmed the possibility of the proposed technology in 8kHz and 20kHz signal detection by smart device.

Wild Fire Monitoring System using the Image Matching (영상 접합을 이용한 산불 감시 시스템)

  • Lee, Seung-Hee;Shin, Bum-Joo;Song, Bok-Deuk;An, Sun-Joung;Kim, Jin-Dong;Lee, Hak-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.40-47
    • /
    • 2013
  • In case of wild fire, early detection of wild fire is the most important factor in minimizing the damages. In this paper, we suggest an effective system that detects wild fire using a panoramic image from a single camera with PAN/TILT head. This enables the system to detect the size and the location of the fire in the early stages. After converting RGB image input to color YCrCb image, the differential image is used to detect changes in movement of the smoke to determine the regions which may be prone to forest fire. Histogram analysis of fire flame is used to determine the possibility of fire in the predetermined regions. In addition, image matching and SURF were used to create the panoramic image. There are many advantages in this system. First of all, it is very economical because this system needs only a single camera and a monitor. Second, it shows the live image of wide view through panoramic image. Third, this system can reduce the quantity of saved data by storing panoramic images.

The Acute and Chronic Toxicity Studies of Herbicide, Molinate to Waterfleas (Molinate의 물벼룩에 대한 급성 및 만성독성 연구)

  • Shin, On-Sup;Kim, Byung-Seok;Park, Yeon-Ki;Park, Kyung-Hoon;Lee, Je-Bong;Kyung, Kee-Sung;Ahn, Young-Joon
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.3
    • /
    • pp.215-221
    • /
    • 2008
  • To assess the impact of molinate on freshwater aquatic organisms, acute and chronic toxicity studies for waterfleas were conducted. In acute toxicity studies for Daphnia magna, and Moina macrocopa, the 48-h $EC_{50}$ values were 11.4 and 8.3 mg/L respectively. And in reproduction toxicity studies for the same species, the NOEC's were 2.5 and 2.0 mg/L respectively. These results suggest that waterfleas have simillar sensitivity to molinate. On the other hand, the NOEC for 3-generation toxicity of moina macrocopa 0.16 mg/L, was much lower than those of acute values. This studies concludes that molinate has minimal risk to waterfleas in river.

Extraction of Smoking in Elevator Using χ2 Histogram (χ2히스토그램을 이용한 승강기 내의 흡연 추출)

  • Shin, Seong-Yoon;Kim, Hee-Ae;Jin, Chan-Yong;Park, Sang-Joon;Rhee, Yang-Won;Lee, Hyun-Chang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.119-121
    • /
    • 2013
  • The fact of smoking is prohibited in elevators. Smoking in elevators that contrary to business ethics, and it can be fatal to our children and women. In this paper, people who smoke in elevators is submitted to forensic evidence. Method is to extract the white bar at the mouth, biting people that smoke. ${\chi}^2$ histogram of scene change detection method is extracted.

  • PDF

A Study on the Improvement for Sensitivity Test of Flame Detectors (불꽃화재감지기의 시험기준 개선에 관한 연구)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.58-61
    • /
    • 2014
  • Flame detectors has been used more than heat & smoke detector, because this is more effective to catch fire and ceiling height in spite of high price. For upgrade to flame detector, Compare to national or abroad standard about performance test, sensitivity test, sectioning indoor or outdoor, after service and management. As a result, Europe and America have only sensitivity test, no have not operation test and sectioning indoor & outdoor. In performance test, action is put to focus to credit and durability, Not operation test is to be able to tune the sensitivity to match the environment of the site. Also, we need code about aftercare, quality assurance responsibility and implement special detector institution by Certificate Authority implement.

Improved Focal Liver Lesion Detection by Increasing Flip Angle During Gadoxetic Acid-Enhancement in MRI (Gadoxetic acid 조영증강 자기공명영상에서 숙임각 변화에 따른 국소 간종양 검출능 비교)

  • Lee, SeJy;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.115-120
    • /
    • 2015
  • To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)'s enhanced MR imaging with a flip angle (FA) of $30^{\circ}$ compared with a $11^{\circ}$. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA $11^{\circ}$ and $30^{\circ}$ images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA $30^{\circ}$ images was found to be superior than FA $11^{\circ}$, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA $30^{\circ}$ image(p<0.05) was better than FA $11^{\circ}$ therefore, the FA $30^{\circ}$ improves the focal liver lesion detection. FA $30^{\circ}$ of MR image can detect liver lesion more sensitively than the existing $FA11^{\circ}$ image after GA contrast enhancement at 15 minute time point.

A Study on the Use of Wireless Signals of Mobile Phones for Effective Rescue Activities at Fire Sites (화재 현장에서 효과적인 구조활동을 위한 휴대전화의 무선 신호 활용 방안 연구)

  • Kim, Younghyun;Kim, Boseob;Jung, Jongjin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.235-236
    • /
    • 2021
  • As a result of analyzing the fire accident of the Jecheon complex that occurred at the end of 2017, there have been many casualties due to delays in checking the location information of isolated people. In order to prevent such an accident, various research has been conducted to estimate the location of requesters by means of detecting wireless communication information of mobile phones existing at disaster sites. The main concept is to detect an RF signal of a mobile phone at fire sites and, based on this, precisely estimate the location of the mobile phone on the LOS/NLOS. However, it is difficult to get visibility at fire sites due to smoke and the fire. Therefore, apart from estimating the location of requesters, a research is also needed to determine the direction of entry within fire sites. In this paper, we propose a method to determine a direction of entry to provide effective rescue activities using wireless communication information of mobile phones.

  • PDF

A Study on the Calculation of the Number of Rescuers at Fire Sites Using Wireless Signals of Mobile Phones (화재 현장에서 휴대전화 무선 신호를 활용한 구조대원 투입 인원수 산출 연구)

  • Kim, Younghyun;Kim, Boseob;Lee, Sungwoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.275-276
    • /
    • 2021
  • In the event of a fire in a complex, the identification of isolated people's location information is delayed, resulting in many casualties. In order to prevent such an accident, research on estimating the location of the requesters by detecting the wireless signal of the mobile phone at fire sites is in progress. The main concept is to use a wireless signal scanner to detect the wireless signal of a mobile phones at fire sites, and then position the mobile phone based on this. However, it is difficult to secure visibility at the fire site due to the smoke, and there is a difficulty in rescuing requesters in need compared with general disaster sites. Therefore, it will be one of the important issues to be solved to determine the minimum number of rescuers to be deployed according to the number and condition of the requesters. In this study, we propose a method to calculate the number of rescuers put to fire sites by using the radio signal generated from mobile phones and the information generated from the inertial sensor of the mobile phones.

  • PDF

ICT Medical Service Provider's Knowledge and level of recognizing how to cope with fire fighting safety (ICT 의료시설 기반에서 종사자의 소방안전 지식과 대처방법 인식수준)

  • Kim, Ja-Sook;Kim, Ja-Ok;Ahn, Young-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2014
  • In this study, ICT medical service provider's level of knowledge fire fighting safety and methods on coping with fires in the regions of Gwangju and Jeonam Province of Korea were investigated to determine the elements affecting such levels and provide basic information on the manuals for educating how to cope with the fire fighting safety in medical facilities. The data were analyzed using SPSS Win 14.0. The scores of level of knowledge fire fighting safety of ICT medical service provider's were 7.06(10 point scale), and the scores of level of recognizing how to cope with fire fighting safety were 6.61(11 point scale). level of recognizing how to cope with fire fighting safety were significantly different according to gender(t=4.12, p<.001), age(${\chi}^2$=17.24, p<.001), length of career(${\chi}^2$=22.76, p<.001), experience with fire fighting safety education(t=6.10, p<.001), level of subjective knowledge on fire fighting safety(${\chi}^2$=53.83, p<.001). In order to enhance the level of understanding of fire fighting safety and methods of coping by the ICT medical service providers it is found that: self-directed learning through avoiding the education just conveying knowledge by lecture tailored learning for individuals fire fighting education focused on experiencing actual work by developing various contents emphasizing cooperative learning deploying patients by classification systems using simulations and a study on the implementation of digital anti-fire monitoring system with multipoint communication protocol, a design and development of the smoke detection system using infra-red laser for fire detection in the wide space, video based fire detection algorithm using gaussian mixture mode developing an education manual for coping with fire fighting safety through multi learning approach at the medical facilities are required.