• Title/Summary/Keyword: 에코

Search Result 1,085, Processing Time 0.032 seconds

Heart-base Tumors in Three Yorkshire Terriers (세 마리 개에서 발생한 심저부 종양 증례)

  • Kwon, Jeong-Kuk;Chung, Woo-Jo;Jang, Ju-Won;Kim, Young-Il;Chung, Dae-Won;Jeoung, Seok-Young;Chung, Jin-Young
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.303-306
    • /
    • 2014
  • Three Yorkshire Terriers (12-year-old, 13-year-old, and 15-year-old castrated males) with respiratory distress, coughing and anorexia were the subjects of this report. In laboratory examinations, there were no remarkable findings. However, the thoracic radiographic findings included a large mass of soft tissue density in the cardiac base region, tracheal elevation, and aortic bulging in all three Yorkshire Terriers. There were no remarkable findings in the abdominal radiographs. In echocardiography, a homogeneous hyperechoic mass around the aorta and bicuspid valve regurgitation were found in all three dogs. There were no remarkable findings in abdominal ultrasonography. Computed tomographic findings showed a large well -defined heterogeneous mass in the cranial vena cava, which was dominant in the left side in all three Yorkshire Terriers. The mass sizes were about $3{\times}4cm$. In post-contrast scanning, contrast enhancement was evident. These cases were diagnosed as heart-base tumor. Treatments provided to the three dogs were based on symptomatic medical management of cardiac failure and tracheal collapse. Case 1 (12-year-old) survived for 3 months, case 2 (13-year-old) for 5 months, and case 3 (15-year-old) for 32 months after the diagnosis. Our results show that the clinical findings, thoracic radiography, echocardiography, computed tomography (CT) and symptomatic medical management in dogs suspected to have heart base tumor.

Comparison of Utrasonic and Vibration Diagnostic Techniques for the Inspection of Pipes in CVD System (화학증착 시스템에서의 파이프내 오염입자 관찰을 위한 초음파 및 진동 진단법의 비교연구)

  • Yun Ju-Young;Seong Dae-Jin;Shin Yong-Hyoen;Lee Ji-Hun;Moon Doo-Kyung;Kang Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.421-426
    • /
    • 2006
  • In examining particulate deposits in the pipes of a chemical vapor deposition (CVD) system, vibration diagnostics is compared and studied against ultrasonic diagnostics, The latter method involves pulsing the outer wall of pipes with an ultrasonic sensor and analyzing the resulting echo to observe particulate deposits inside pipes. Vibration diagnostics examines the existence of particulate deposits by analyzing the difference in the frequencies generated when a vibrator is adhered to the outer wall of pipes. With ultrasonic diagnostics, good test results were obtained only when particulate deposits were attached to the inner wall of the pipes, After some time, however, particulate deposits were not detected properly, as the ultrasonic wave failed to cross the fine gaps created between the inner wall of the pipe and the deposits. The ultrasonic wave bounced back because of the dried particulate deposits on the wall. Thus, it has been proven that the ultrasonic diagnostics is not an appropriate means of examining the particulate deposits in a vacuum, On the other hand, vibration diagnostics succeeded in detecting the particulate deposits regardless of the lapsed time. In conclusion, the vibration diagnostics is being expected as the effective method in monitoring the particulate deposits inside pipes in the CVD system where the desired behavior is reduced frequency along with the particulate deposits in comparison to the case where the pipe is clean.

The Analysis of the Relationships between Environmental Factors and Environmental Performance of Distribution Companies (물류기업의 환경요인과 환경성과간의 관계 분석)

  • Noh, Mijin;Jang, Sunghee;Ahn, Hyunsook
    • Journal of Korea Port Economic Association
    • /
    • v.30 no.3
    • /
    • pp.141-161
    • /
    • 2014
  • The Global economic development and high levels of industrialization force many companies to consider an adoption of GSCM. This study investigates characteristics of GSCM focused on the environmental management of distribution companies. The purposes of this study are as follows; first, we examine environmental factors of GSCM companies, and relationships between environmental factors and environmental performance. The environmental factors of GSCM companies were assorted into supplier, marketing, competitor, internal business environment, and eco-design. Second, we study the influences of environmental factors on the environmental performance in the GSCM companies according to the agility. 118 questionnaires collected from distribution companies based on GSCM, and the research model was tested by Smart PLS. The results of this study are as follows; first, the GSCM environmental factors like supplier, marketing, competitor, internal business environment, and eco-design had a positive effect on the environmental performance. Second, the environmental factors like marketing and competitor had a positive effect on the environmental performance according to the agility. These results could provide useful guidelines for distribution companies and academic implications for researchers.

Signal-Characteristic Analysis with Respect to Backing Material of PVDF-Based High-Frequency Ultrasound for Photoacoustic Microscopy (광음향 현미경을 위한 PVDF 기반 고주파수 초음파 변환기의 흡음층 소재에 따른 신호 특성 분석)

  • Lee, Junsu;Chang, Jin Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.112-119
    • /
    • 2015
  • Photoacoustic microscopy is capable of providing high-resolution molecular images, and its spatial resolution is typically determined by ultrasonic transducers used to receive the photoacoustic signals. Therefore, ultrasonic transducers for photoacoustic microscopy (PAM) should have a high operating frequency, broad bandwidth, and high signal-reception efficiency. Polyvinylidene fluoride (PVDF) is a suitable material. To take full advantage of this material, the selection of the backing material is crucial, as it influences the center frequency and bandwidth of the transducer. Therefore, we experimentally determined the most suitable backing material among EPO-TEK 301, E-Solder 3022, and RTV. For this, three PVDF high-frequency single-element transducers were fabricated with each backing material. The center frequency and -6 dB bandwidth of each transducer were ascertained by a pulse-echo test. The spatial resolution of each transducer was examined using wire-target images. The experimental results indicated that EPO-TEK 301 is the most suitable backing material for a PAM transducer. This material provides the highest signal magnitude and a reasonable bandwidth because a large portion of the energy propagates toward the front medium, and the PVDF resonates in the half-wave mode.

Effects of Environmental Infrastructure Regeneration in Urban Region - A Case Study of M Apartment Complex in Daejeon (도시 단지내 환경 인프라 재생 효과 고찰 - 대전시 M 아파트 단지 사례연구)

  • Park, Kiyong;Choi, Changkyoo;Shin, Jongseok;Park, Heekyeng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.353-359
    • /
    • 2015
  • This study introduces a resource recycling system in urban apartment complex using four different technologies. The four technologies, called 4G, include a production technology for reclaimed water (Green water), a biogas production technology from organic waste (Green biogas), a reuse technology of rainwater (Green rainwater), and urban agropark (Green pyramid). Green water is the technology for producing the reclaimed water from wastewater, rainwater and underground water, and the average concentrations of BOD, SS, T-N and coliform of reclaimed water were 7.8mg/L, ND (not detected), 4.9mg/L and ND, respectively. Green biogas is the technology for producing biogas and effluent after treating organic wastes (e.g. food waste and night soil) discharged from households, and the average production rates of hydrogen and methane were $0.33m^3/m^3/d$ and $0.24m^3/m^3/d$, respectively. Green pyramid, agricultural farm operated by biogas and reclaimed water, provides a healthy and recreational space for residents, and plant growth rates using treated water and reclaimed water showed height of 1.32cm and weight of 112.8g. Therefore, 4G technologies can improve the recycling rate and treatment efficiencies of waste and wastewater in an apartment complex.

Klebsiella Pneumonia-Necrotizing Fasciitis followed by Liver Abscess (폐렴 간균-괴사성 근막염에 이어 발생한 간농양)

  • Lee, Seung Hyun;Choi, Jeong Woo;Lee, Myeung Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.427-431
    • /
    • 2018
  • We report a case of a patient with necrotizing fasciitis followed by liver abscess. A 51-year-old man was admitted to our hospital with a 5-day history of fever and chills with painful swelling of the right thigh. A magnetic resonance imaging (MRI) scan showed fluid collection with numerous dark signal intensities considered as air-bubbles between the posteromedial and posterolateral groups of the right thigh, resulting in presumptive diagnosis of necrotizing fasciitis. At the time of admission, an ultrasonograph of the abdomen showed increased parenchymal echogenicity of both kidneys and no liver abscess. Ten days after fasciotomy, an abdominal computed tomography (CT) scan showed intrahepatic abscess. Sonography-guided percutaneous drainage was performed. Both cultures of pus specimens from the liver abscess and right thigh yielded Klebsiella pneumoniae (K. pneumoniae). The patient was treated with fasciotomy several times and parenteral antibiotics, after which he began to improve. After 5 weeks, liver abscess size was reduced, and after 10 weeks, liver abscess disappeared. To the best of our knowledge, this is the first case of K. pneumoniae-necrotizing fasciitis followed by liver abscess.

A Study on the Landscape Design for Sunchon National University Cultural Park (순천대학교 문화공원 설계)

  • Kim, Youn-Jin;Han, Sun-Ah;Kim, Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.4
    • /
    • pp.75-83
    • /
    • 2010
  • College campus landscape plans once focused mainly on campus functionality and aesthetically pleasing buildings. Yet now, after the rise of greater emphasis on afforestation and eco-friendly planning, building spaces for the local culture and community has become the core of the plan. This study analyzed the design strategies and details of the landscape plan that was selected through the contest to select a design plan for the cultural park at Sunchon National University. The key considerations for the landscape Design for the cultural space at Sunchon National University areas follows. First, the design plan sought ways to reach out to the local community, going one step beyond just opening up campus facilities. This means more than just the opening of physical facilities and environments. It was designed to serve as a base to organize diversified programs by generations and groups with an aim to share the history and culture of the college, the local community and the region. Second, shapes and colors were designed to establish a unified image between buildings and outdoor facilities. "Three Books" was selected as the key motif as books were believed to be the most representative symbol of colleges while 6 straight lines, hexagons and circles inspired by the shape of three books were used in the design. In terms of colors, reddish-brown was used for buildings to enhance visibility along with harmony and esthetic appreciation. For facilities, black and blue were used as dominant colors and white and yellow as point colors to promote the image of Sunchon City. Third, with an aim to overcome the limitation of the overall college campus as a closed space, it was designed to be a barrier-free space, remaining open to everyone and encouraging visits and experiences for active communication with the local community.

Design and Implementation of NMEA Multiplexer in the Optimized Queue (최적화된 큐에서의 NMEA 멀티플렉서의 설계 및 구현)

  • Kim Chang-Soo;Jung Sung-Hun;Yim Jae-Hong
    • Journal of Navigation and Port Research
    • /
    • v.29 no.1 s.97
    • /
    • pp.91-96
    • /
    • 2005
  • The National Marine Electronics Association(NMEA) is nonprofit-making cooperation composed with manufacturers, distributors, wholesalers and educational institutions. We use the basic port of equipment in order to process the signal from NMEA signal using equipment. When we don't have enough one, we use the multi-port for processing. However, we need to have module development simulation which could multiplex and provide NMEA related signal that we could solve the problems in multi-port application and exclusive equipment generation for a number of signal. For now, we don't have any case or product using NMEA multiplexer so that we import expensive foreign equipment or embody NMEA signal transmission program like software, using multi-port. These have problems since we have to pay lots ci money and build separate processing part for every application programs. Besides, every equipment generating NMEA signal are from different manufactures and have different platform so that it could cause double waste and loss of recourse. For making up for it, I suggest the NMEA multiplexer embodiment, which could independently move by reliable process and high performance single hardware module, improve the memory efficiency of module by designing the optimized Queue, and keep having reliability for realtime communication among the equipment such as main input sensor equipment Gyrocompass, Echo-sound, and GPS.

Improvement of Rainfall Estimation according to the Calibration Bias of Dual-polarimetric Radar Variables (이중편파레이더 관측오차 보정에 따른 강수량 추정값 개선)

  • Kim, Hae-Lim;Park, Hye-Sook;Ko, Jeong-Seok
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.12
    • /
    • pp.1227-1237
    • /
    • 2014
  • Dual-polarization can distinguish precipitation type and dual-polarization is provide not only meteorological phenomena in the atmosphere but also non-precipitation echoes. Therefore dual-polarization radar can improve radar estimates of rainfall. However polarimetric measurements by transmitting vertically vibration waves and horizontally vibrating waves simultaneously is contain systematic bias of the radar itself. Thus the calibration bias is necessary to improve quantitative precipitation estimation. In this study, the calibration bias of reflectivity (Z) and differential reflectivity ($Z_{DR}$) from the Bislsan dual-polarization radar is calculated using the 2-Dimensional Video Disdrometer (2DVD) data. And an improvement in rainfall estimation is investigated by applying derived calibration bias. A total of 33 rainfall cases occurring in Daegu from 2011 to 2012 were selected. As a results, the calibration bias of Z is about -0.3 to 5.5 dB, and $Z_{DR}$ is about -0.1 dB to 0.6 dB. In most cases, the Bislsan radar generally observes Z and $Z_{DR}$ variables lower than the simulated variables. Before and after calibration bias, compared estimated rainfall from the dual-polarization radar with AWS rain gauge in Daegu found that the mean bias has fallen by 1.69 to 1.54 mm/hr, and the RMSE has decreased by 2.54 to 1.73 mm/hr. And estimated rainfall comparing to the surface rain gauge as ground truth, rainfall estimation is improved about 7-61%.

Diagnosis of Chronic Kidney Disease using Sonography (초음파 영상을 이용한 만성 콩팥병의 진단)

  • Ahn, Yu-Ji;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Chronic kidney disease can be treated if it is detected early, but as the disease progresses, it becomes impossible to recover. Finally, renal replacement therapy such as transplantation or dialysis should be used. Ultrasonography is used to diagnose kidney cancer, inflammatory disease, nodular disease, and chronic kidney disease. It is used to identify information about degree of inflammation using information such as kidney size, internal echo characteristics. Currently, the degree of disease in the clinic uses the value of glomerular filtration rate. However, even in ultrasound, changes in the degree of inflammation and disease can be observed. In this study, we used ultrasound images to quantify the changes in brightness, size, cortex, and subclinical changes of the kidney with progression of the disease, and compared them with the glomerular filtration rate used in clinical practice. In 105 cases, we performed 35 cases of normal kidney, 35 cases of early kidney disease, and 35 cases of terminal kidney. The brightness of the cortex of the image was obtained and the difference in brightness between the cortex and the proximal portion was obtained by the slope. The graph of the portion which was not smooth due to the ultrasonic characteristics was used as the function regrass. The size reduction was obtained from the original data. The results were as follows: It was proportional to the glomerular filtration rate. It is considered that the algorithm can be applied to the disease if the algorithm study continues.