• Title/Summary/Keyword: 애자일

Search Result 552, Processing Time 0.025 seconds

Development of Working Platform for the Polymer Insulator String (송전선로 폴리머애자 공사용 장비 개발)

  • Min, Byeong-Wook;Wi, Shwa-Bok;Bang, Hang-Kwon;Choi, Han-Yeol;Baek, Soo-Gon;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.438-439
    • /
    • 2006
  • Porcelain insulators have generally been used in Korea to insulate a transmission line from the tower, and a highly polymerized compound polymer insulator which has superior stain proof characteristics, has also been used widely. Currently, a worker rides on the suspension insulator string for installation on towers and conductors but in case of polymer insulators, this will pollute and scratch the housing result in durability reduction by deterioration and corona. This study developed a high strength aluminum compound metal lauder designed to work on polymer insulators without riding, and a clamp type connecting device and safety gear for easy installation on the tower and conductor. These polymer insulator work device can be used for 154kV and 345kV polymer insulators through a strength and load test to secure safety. This paper presents field usage.

  • PDF

Development of Hold on Swing a Jumper Support String for Overhead Transmission Line (송전선로 점퍼선 횡진방지용 지지애자장치 개발)

  • Baik, Seung-Do;Min, Byeong-Wook;Wi, Hwa-Bog;Park, Kee-Yong;Keum, Eui-Yeon;Jeong, Heon-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.521-523
    • /
    • 2005
  • A Jumper wire is currently used to connect each fixed power line on both sides of dead end tower for overhead transmission line, but in case of a jumper wire swing under circumstances of typhoon, etc. and the air clearance is deficient then a flashover fault may Happen. Now the angle tower has the jumper support string to prevent a swing of jumper wire and to secure the air clearance between jumper wire and tower main body, but the flashover fault by swing of jumper wire was happened yl times across all over the country, because of the typhoon 'Rusa' in year 2002 and 'Maemi' in year 2003. This paper presents the design and development of 'Counter Weight' which enables to keep the swing angle of jumper wire under 40 degree in design condition to prevent a flashover fault by swing of jumper wire by a high wind pressure load in case of typhoon and have completed a mechanical and electrical characteristic test.

  • PDF

Development of a Ubiquitous Sensor for Monitoring Insulators and Lightning Arresters (애자/피뢰기 모니터링을 위한 유비쿼터스 센서 개발)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Song, Jae-Yong;Kim, Il-Kwon;Park, Dae-Won;Choi, Soo-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.117-123
    • /
    • 2007
  • In this study, a ubiquitous sensor for condition monitoring of insulators and lightning arresters installed in power distribution lines and electric traction vehicles is presented. The sensor consists of two parts; a leakage current measurement and a lightning surge detection. Measured data are transmitted to a supervisory computer through ZigBee protocol based on IEEE 802.15.4. To detect leakage current, a window type Mn-ZCT is used and a low-noise amplifier with a gain of 60dB is designed, and this can measure leakage current in ranges of $100{\mu}A{\sim}5mA$. A sample-hold (S/H) and a Rogowski coil are injected to analyze the magnitude of surge current in ranges from 100A to 10kA with $8/20{\mu}s$-waveform.

A Development of V type Suspension String Set for UHV Transmission Lines (초고압 송전선로용 V련 현수애자장치의 개발)

  • Sohn H. K.;Lee H. K.;Keum E. Y.;Min B. W.;Choi J. S.;Choi I. H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.497-499
    • /
    • 2004
  • Due to a typhoon named MAEMI on Sep12, 2004, 7 transmission towers collapsed and 3 were damaged in the Gyeongnam and Busan areas. These caused long-term black-outs in Goeje-do. When a transmission tower collapses or is damaged, Construction will take more than 2 months and this will be accompanied by long-term black-outs. Therefore a temporary iron pole is used in such emergencies. Current temporary rehabilitation angle steel iron Pole consistes of around 800 members, 2,800 bolts and it takes about 5 days to construct a temporary transmission line. Consiquently wide black-outs occur during the construction of the temporary transmission line. To reduce black-out time, the construction period must be reduced as much as possible. This paper presents new methods to reduce temporary transmission line construction time to within 48 hours by applying a self-reliance assembling method instead of the current man power assembling method and by modulizing each angle steel with duralumin.

  • PDF

A Study on the Comparison and Analysis of Leakage Current according to Environmental Variation of EHV insulators(36,000LBS) by Pollution Level (송전용 자기애자(36,000LBS)의 오손 등급별 환경변화에 따른 누설전류 분석 및 비교 연구)

  • Choi I. H.;Choi J. H.;Jung Y. H.;Lee D. I.;Jung G. J.;Shin T. W.;Bang H. K.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.527-529
    • /
    • 2004
  • This paper researched leakage current characteristics of EHW insulators(36,000lbs) to artificially contaminated clay and kaolin through construction of long-periods testing facility. Insulators were contaminated and classified into the ESDD level(B, C and D) under IEC Pub. 60507 standards method. As a result of tests, leakage current of the heavily contaminated D level to clay was approximately 2,260 $[\muA]$, which is contaminated to kaolin was approximately 3,200 $[\muA]$, during initial rainfall. However after raining, leakage current of naturally washed contamination insulators was lower at approximately 300 $[\muA]$. As regular temperature $20^{\circ}C$, leakage current increased greatly in case humidity density was over $72\%$. But, leakage current was not influenced by temperature variation in case of regular $\%$ humidity.

  • PDF

The criterion of reliability evaluation and the evaluation facility for composite insulator (폴리머 애자 신뢰성평가 기준 제정 방향 및 평가설비 구축)

  • Kim, I.S.;Kim, M.K.;Kim, I.K.;Kang, D.P.;Park, H.Y.;Han, D.H.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.147-148
    • /
    • 2001
  • The construction of reliability evaluation according to their fields was promoted under the supervision of Agency for Technology and Standards for establishing the relevant institution & infrastructure that can fundamentally solve the reliability problems, the biggest obstruction when the developed electric components & materials come into the market. This paper describes the criterion of reliability evaluation and the evaluation facilities for the purpose of heightening the reliability of composite insulator estimated as the new material among the electric components & materials. We will understand the criterion of reliability evaluation with two parts as the performance evaluation based on various kinds of standards (especially IEC) and as the long-term reliability evaluation utilizing the accelerated aging & flashover test methods. Therefore we aim for constructing the criterion of reliability evaluation as the foundation for evaluation so as to support the industrial group based on KERI facilities.

  • PDF

Signal Classification of Electromagnetic Wave for Contaminated Degree on Polymer Insulator (고분자 애자 오손정도의 전자파 신호 분석)

  • Park, Jae-Jun;Choi, In-Hyuk;Jung, Myeong-Yeon;Lee, Seung-Wook;Seo, Euy-Won;Ka, Pyeong-Hyeon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.662-665
    • /
    • 2004
  • Recently, diagnosis techniques have been investigated to detect a partial discharge associated with a dielectric material defect in a high-voltage electrical apparatus However, the properties of detection technique of PD aren't completely understood because the physical process of PD. Therefore, this paper analyzes the process on Surface Discharge of Polymer Insulator using Wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time-frequency domain. As it is important to develop a non-contact method for detecting the Contamination Degree, this paper analyzes the electromagnetic waves emitted from PD using Wavelet transform. This paper experimentally shows the process of PD as a two-dimensional distribution in the time-frequency domain. This method is shown to be useful for detecting prediction of contamination degree.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

Experimental Study on the Dynamic Characteristics of Porcelain Surge Arrestor Considering the Variation of Cable's Tension and Arrestor's Stiffness (케이블 장력 및 피뢰기의 강성 변화를 고려한 애자형 피뢰기의 동특성 시험 연구)

  • Jang, Jung Bum;Hwang, Kyeong Min;Yun, Kwan Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.253-259
    • /
    • 2014
  • Porcelain surge arrestor is very vulnerable to earthquake but there is very few information on its dynamic characteristics which are necessary to the seismic design. Therefore, the dynamic characteristics of the porcelain surge arrestor are evaluated considering the variation of its cable tension and stiffness by shaking table test. The test results show that the first natural frequencies are 5.3 Hz and 5.2 Hz in the horizontal x- and y-axis directions, respectively, and higher than 30 Hz in the vertical z-axis direction, respectively. The installation of cable on the surge arrestor reduces the horizontal natural frequencies due to the constraint effect of the cable but cable tension has no effect on the natural frequency. Also, the natural frequency is proportional to the stiffness of the surge arrestor. This test result will be used for the seismic design and seismic capacity assessment of domestic substations and contribute to the stability of the electric power supply under earthquake event.

Multi-scale simulation of drying process fey porous materials using molecular dynamics (part 3: multi-scale simulation) (분자동역학을 이용한 다공성 물질 건조공정 멀티스케일 시뮬레이션(3부: 멀티스케일 시뮬레이션))

  • Baik S.M.;Keum Y.T.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.4
    • /
    • pp.168-174
    • /
    • 2005
  • In this study, the numerical simulation of drying processes for porous materials is performed by employing the hierarchical multi-scale modeling and the nano-scale material properties obtained from the molecular dynamics simulation. The multi-scale simulation system is set up using pre- and post-processors and the drying process of electric porous ceramic insulator is simulated. The temperature, moisture, residual stress, and displacement distributions are compared with those based on homogenized properties.