• Title/Summary/Keyword: 압박지수

Search Result 35, Processing Time 0.027 seconds

Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination (유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this study is to investigate the cause analysis according to the difference between the pre exposure tube voltage and actual exposure tube voltage in mammography in connection with breast pressure thickness, breast size and body mass index and to find the improvement. The study tracked 377 women age 40 and older among the mammography examiners conducted by the National Health Insurance Corporation. It was analyzed that breast pressure thickness, breast size and body mass index according to the difference between the pre exposure tube voltage and actual exposure tube voltage among the parameters of dose report been sent to the picture archiving communication system with reference to the image with cranio-caudal projection in mammography. As are result, it shows that the thicker the breast thickness, smaller the breast size and lower body mass index, the higher the difference of tube voltage. In conclusion, the minimum tube voltage of mammography machine should be reset in order to set the tube voltage according to breast pressure thickness and breast size that are suitable for our country in mammography, in addition, it was considered that radiologist should make an effort to reduce radiation exposure and make a good quality image with reducing the difference of mammography condition by making a correct exposure condition in case of examining the patients with thin breast pressure and small breast size.

Effect of Wearing a Compression Stocking on Electromyogram of the Legs (동일인에서 한쪽 다리에만 압박스타킹을 착용했을 때 유발되는 다리 근육의 근전도 변화에 대한 정량적 분석)

  • Lee, Ji-Youn;Yuk, So-Hee;Yoo, Hyo-Gyung;Hong, Nam-Ju;Jeon, In-Cheol;Jung, Dongju
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.185-190
    • /
    • 2019
  • Compression stockings are widely used for prevention of varicose vein. Depending on manufacture, there are diverse types of compression stockings available. Most common type of compression stocking might be the one cover calf of a lower leg which has 20~30 mmHg pressure. Despite being widely used, possible side effects that may occur by wearing compression stockings have not been studied much. We analyzed for a long wearing effect of compression stocking. Participants wore the compression stocking over one leg for 7 days. During the period, all the participants did their ordinary works wearing the compression stocking. Electrocardiogram (ECG), ankle-brachial index (ABI), blood pressure (BP), and electromyogram (EMG) were measured at 0 day, 3rd day and 7th day. There was no effect of wearing compression stockings from ECG, ABI or BP. Only EMG that was measured on the covered muscle increased proportionally to the wearing time. Interestingly, EMG from the opposite leg that had never been covered by compression stocking decreased in proportion to the wearing date. These results suggest wearing a compression stocking for varicose vein may cause unintentional increase or decrease of EMG from the wearing or non-wearing legs, respectively.

The Effect of Inclusion on the KOSPI 200 on Stock Prices (KOSPI 200 진입기업의 주가행태)

  • Kwon, Taek-Ho;Park, Jong-Won
    • The Korean Journal of Financial Management
    • /
    • v.17 no.2
    • /
    • pp.49-70
    • /
    • 2000
  • 본 연구에서는 한국주식시장의 대표적 주가지수인 KOSPI 200 진입기업과 제외기업의 주가 행태에 어떤 변화가 있는지를 분석하였다. 1994년 6월 이후부터 1999년 정기변경때까지의 기간에 KOSPI 200에 새로 진입한 종목과 제외된 종목을 검증표본으로 하고 이와 유사한 특성을 가지는 기업들을 대응표본으로 삼아 두 집단간에 나타나는 비정상수익률 및 누적비정상수익률의 특성과 비정상수익률과 비정상거래량간의 관계를 비교 분석하였다. 사건일의 비정상수익률과 사건기간동안의 누적비정상수익룰에 대한 분석결과는 KOSPI 200에 새로 포함되거나 제외되는 종목의 주가행태에 뚜렷한 변화가 있다는 결과를 보여주지는 못하고 있다. 그러나 일부 표본의 분석결과는 KOSPI 200에 새로 진입하거나 제외되는 정보가 공시일 이전에 시장에 반영되는 모습을 보여주며, 외환위기 이후기간에 발생한 정기변경진입종목에 나타난 주가행태 변화와 주가변동과 거래량 변동간의 관계는 일부 가격압박가설로 설명될 수 있음을 보여준다. 그러나 본 연구의 분석결과는 지수 신규편입 종목들이 펀드에 신규로 편입되는 과정에서 거래량이 증가해 초과수익이 발생한다는 기존의 가격압박가설의 내용을 충분히 지지하지는 못하고 있다.

  • PDF

The Market Effect of Additions or Deletions for KOSPI 200 Index : Comparison between Groups by Size and Market Condition (KOSPI 200지수종목의 변경에 따른 시장반응 : 규모와 시장요인에 따른 그룹간 비교분석)

  • Park, Young-S.;Lee, Jae-Hyun;Kim, Dae-Sik
    • The Korean Journal of Financial Management
    • /
    • v.26 no.1
    • /
    • pp.65-94
    • /
    • 2009
  • The event of change in KOSPI 200 Index composition is one of the main subjects for the test of EMH. According to EMH, when a certain event is not related with firm's fundamental value, stock price should not change after the announcement of news. This hypothesis leads us to the conclusion of horizontal demand curve of stock. This logic was questioned by Shleifer(1986) and argued that downward sloping demand curve hypothesis was supported. But Harris and Gruel(1986) found a different empirical evidence that price reversal occurs in the long run, which is called price pressure hypothesis. They argued that short term price effect by large block trading (price pressure) is offset in the long run because these event is unrelated to fundamental value. Therefor, they argued that EMH can not be rejected in the long run. Until now, there are two empirical studies with Korean market data in this area. Using a data with same time period of $1996{\sim}1999$, Kweon and Park(2000) and Ahn and Park(2005) showed that stock price or beta is not significantly affected by change in index composition. This study retested this event expanding sample period from 1996 to 2006, and analyzed why this event was considered an uninformative events in the preceding studies. We analyzed a market impact by separating samples according to firm size and market condition. In case of newly enlisted firm, we found the evidence supporting price pressure hypothesis on average. However, we found the long run price effect in the sample of large firms under bearish markets. At the same time, we know that the number of samples under the category of large firms under bearish markets is relatively small, which drives the same result of supporting the hypothesis that change in index composition is a non-informative event on average. Also, the long run price effect of large size firms under bearish markets was supported by the analyses using trading volumes. On the other hand, in case of delisting from the index, we found the long run price effect but that was not supported by trading volume analyses.

  • PDF

Effects of swimming on functional recovery and brain-derived neurotrophic factor (BDNF) mRNA expression after sciatic crushed nerve injury in rats

  • Lee Myoung-Hwa;Byun Yong-Hyun;Yoon Bum-Chul;Kim Chang-Ju
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.128-139
    • /
    • 2004
  • 말초신경은 외상이나 질병 등 여러 가지 원인으로 손상되기 쉬우며, 손상의 정도가 심하거나 치료가 지연되는 경우에는 심각한 기능 소실을 초래할 수 있다. 본 연구에서는 수영이 말초신경손상후 운동기능의 회복과 뇌유인성 신경영양인자 (brain-derived neurotrophic factor, BDNF) mRNA의 발현에 미치는 효과를 알아보기 위하여, 흰쥐 좌골신경에 압박 손상을 가하고 수영을 적용한 후 보행궤적분석 (walking track analysis)과 역전사연쇄반응 (reverse transcription-polymerase chain reaction, RT-PCR)을 실시하였다. 그 결과, 좌골신경 압박손상된 쥐는 특징적인 보행패턴을 나타내어 좌골신경기능지수 (sciatic function index, SFI)가 현저히 낮아졌으며, BDNF mRNA의 발현이 증가하였다. 좌골신경 압박 손상후 수영을 한 쥐에서는 SFI가 현저히 향상되었으며, BDNF mRNA의 발현은 억제되었다. 이러한 결과는 말초신경손상후 수영이 BDNF mRNA의 발현을 조절함으로써 기능 회복을 촉진시키는 효과적인 치료방법이 될 수 있음을 제안하고 있다.

  • PDF

Implementation of Non-Invasive Cerebral blood Increasing Platform using PI (혈류지수를 이용한 비침습적 대뇌혈류증가 장치의 구현)

  • Kwon, Seong-tae;Lee, Jean;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.9
    • /
    • pp.1761-1770
    • /
    • 2017
  • Treatment for cerebral blood flows is one of the most important treatments for cerebral infarction. There is a concern that the increasing number of cerebral blood flow treatments can cause multiple complications as it is invasive. To compensate for these problems, recently non-invasive cerebral blood flow increases have emerged. However, the current implementation of the non-invasive cerebral blood flow sensor raises the question of speed and accuracy. In this theses, the system aims to minimize the final cortical damage to the cerebrum by implementing a system in a completely different manner to complement the disadvantages of the existing non-invasive cerebral blood flow device. The system measure the PI of the limbs while simultaneously pressing limbs. Blood flow rate is carried out indirectly by increasing blood flow to peer pressure through the limbs in which the PI eips below a certain level. This can be used selectively in patients to increase blood flow.

Monitoring on Dose Index Analyzed in the Mammography (유방촬영검사에서 선량지표분석에 대한 모니터링)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.477-482
    • /
    • 2016
  • This study is tried to determine whether the management of medical radiation is well handled by comparison the guidelines of KFDA(korea food & drug administration) with analysis of dose indicator in mammography. As a method, it is analysed that kVp, exposure time, mAs, compressed breast thickness, average glandular dose and body mass index that were classified in the examination of both breasts by CC(cranio-caudal) and MLO(medio-lateral oblique) with EMR(electronic medical record) and dose report that were sent to the PACS(picture archiving communication system). As a result, in the site inspection according to the age, Compressed breast thickness in CC and MLO were the thickest of 45.6 mm and 49.6 mm in the 50-59 year old respectively. In the overall average compressed breast thickness, CC were 44.2 mm and MLO were 48.9 mm. MLO has more thick by 4.7 mm. In average glandular dose, CC were 1.05 mGy and MLO were 1.14 mGy. MLO has higher by 0.09 mGy than CC. As the compressed breast thickness increases 10mm, CC and MLO increases 0.15 mGy and 0.17 mGy respectively. When it was compared with the average glandular dose of 1.16 mGy per 1 film presented by KFDA, CC was showed 1.05 mGy. However, the 60 mm or more was found to exceed a 1.30 mGy. Also, As the compressed breast thickness was higher, body mass index showed high score. And in the case of 25 or more in the obese body index according to body mass index, it was showed obesity in case of the compressed breast thickness was more than 50mm.

Usefulness of the Chin Press Maneuver in Assessing the Severity of Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증후군의 진단에 있어 턱 압박술의 유용성)

  • Kim, Moo-Jin
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.1
    • /
    • pp.22-29
    • /
    • 2001
  • Objectives: Obstructive sleep apnea syndrome (OSA) is a moderately prevalent disorder. Even though much progress has been made in the diagnosis of this disorder, the cost-effectiveness of nocturnal polysomnography is undertermined and physicians and patients are still hesitant to undergo this procedure. The authors wanted to see the validity of chin press/tongue curl maneuver in estimating the severity of OSA which is easy to measure and was originally proposed by Simmons etc. by looking at the correlations between this score and the conventional respiratory disturbance indices. Methods: Forty-three sleep-related breathing disorder patients (28 OSA patients and 15 upper airway resistance syndrome (UARS) patients) who underwent investigation for posssible OSA were studied. Two conventional indices of OSA (apnea/hypopnea index (AHI) and oxygen saturation dip rate (SaO2 dips)), four other sleep variables (lowest SaO2, % of time with SaO2<90% (%SaO2 <90), % of sleep stage 1, mean length of SaO2 dips) and the score of Epworth sleepiness scale (ESS) were compared with the chin press score (CPS) which was newly revised by the author and ranges from 0 to 6. Results: The age of subjects was $45.95{\pm}12.47$ (range 14-76) and their average BMI was $25.98{\pm}3.61$ (range 19.65-37.64). There were no significant differences in age, sex and BMI except repiratory disturbance indices and ESS (p<0.05) between OSA and UARS group. Grouped median CPS of the all subjects was 4.14 (range 1-6). There was a remarkable relationship between CPS and diagnosis category (Likelihood Ratio $X^2$ test; $X^2$=17.41, df=5, p=0.004) and measures of association (Somers' $d=0.65{\pm}0.12$, t=4.83, p=0.000) indicated that CPS increased when the diagnosis changed from UARS to OSA. Spearman's rank correlations between CPS and SaO2 dips (R=0.83), between CPS and AHI (R=0.77) were good (p<0.001). Other variables except mean length of SaO2 dips showed good correlations with CPS as well (p<0.05). Regression analysis indicated that when CPS is 3 there is a provability of 0.35 to have AHI of less than 5. Conclusion: Chin press scores that can be measured easily is well correlation with the conventional sleep apnea indices. They may therefore provide a useful guide in diagnosing obstructive sleep apnea synrome.

  • PDF

Evaluation of Breast Dose by Breast Pressure Thickness of Breast Prosthesis Insertion (보형물 삽입 유방의 압박 두께에 따른 유방 선량 평가)

  • Lee, Hyeon-Yong;Kim, Ji-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.469-473
    • /
    • 2020
  • Breast cancer is growing rapidly year by year and has the highest incidence since 2001. As a result, the interest in mammography for early detection of breast cancer is increasing. However, mammography is accompanied by radiation exposure and therefore it is necessary to reduce exposure dose through appropriate test conditions. The significance of this study is that breast dose studies, which were limited to ordinary women, were applied to breast implant patient. Using MCNP simulation, the phantom with prosthesis inserted was developed to compare dose by tube voltage by pressure thickness. In addition phantom without prostheses has higher dose than phantom with prostheses. If these results were used as basic data, it would be possible to recommend test condition guideline only for breast implant patients.

Stress Index Processing Algorithm (스트레스 지수 처리 알고리즘에 관한 연구)

  • Han, Seung-Heon;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.135-138
    • /
    • 2007
  • We may have had experience to use meaning of stress once at least. Because various mental and physical frustration, conflict, deprivation, and pressure have been happened around the us while we live our whole life. The stress is always existing at our surroundings as much. Now, most stress measurement method is composed of mental method and physical method. The accuracy of stress grade lacks to the disproportion of subjectivity, objectivity, and a science trait. Therefore, in this paper, we propose the index processing algorithm for a stress relief better, after mixing mental measurement result and physical measurement result.

  • PDF