• Title/Summary/Keyword: 압력측정센서

Search Result 342, Processing Time 0.03 seconds

Evaluation of Feed Values of Korean Straws Using Pressure Transducer (Auto-Pressure Transducer를 이용한 국내산 고간류의 사료가치평가)

  • Lee, Sang S.;Ha, J. K.;Chang, M. B.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.241-250
    • /
    • 2003
  • Accurate and rapid evaluation of the nutritional quality of Korean straws is important because of the recent increase in the use of these feedstuffs in Korean. The aim of the study was to establish with relationships between ruminal fermentation of Korean straws and in vitro gas production using a pressure transducer. The pressure transducer system includes pressure censors, AD board, LED monitor, and the computer with real-time graphics. Both gas production and DM digestibility data were fitted into the exponential equation P = a + b (1-e-$1-e^{-ct}$). The initial rate of gas production was highest for rice straw, followed by barley straw and wheat straw. The gas production rate of constant (c) in gas production for rice straw, wheat straw, and barley straw were 3.8, 2.5, and 2.5 $%h^{-1}$, respectively. Total VFA concentration (mM) produced after 72h incubation was similar among three Korean straws, even though was variable during the early (12h) fermentation. Volume of gas production was related (P> 0.05: r = 0.76 to 0.83) to DM disappearance and also strongly related (p< 0.05: r = 0.91 to 0.98) to VFA concentration at all incubation times. Linear correlation showed between gas production and DM disappearance and VFA by in vitro will be matched in in vivo digestibility.

Operation Characteristic Analysis of a Comb Actuator due to a Anisotropy Variation in RIE Etching (RIE 식각시 발생하는 비등방도 변화에 따른 머리빗형 액튜에이터의 동작 특성 분석)

  • Kim, Bong-Soo;Park, Ho-Jun;Pak, Jung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.368-376
    • /
    • 1999
  • This paper predicts the changes in the spring constant, the resonant frequency, the electrostatic force, and the displacement of a resonant structure due to non-ideal anisotropic RIE etching process. First, a $6\;{\mu}m$ thick polysilicon was etched by RIE and the anisotropy of the etched structure was measured as a function of a RF power, a $Cl_2$ flow rate and a chamber pressure. In the experimental results, an anisotropy was decreased as the RF power, the $Cl_2$ flow rate, or the chamber pressure was increased. A comb actuator's operation characteristic was predicted depending on the anisotropy variations in RIE etching. Comb actuators with three different support beam structures were investigated : fixed-fixed, crab-leg, and double crab-leg. As the RIE etch anisotropy becomes non-ideal, i.e. the cross section becomes rather a trapezoidal than a rectangular shape, it decreases spring constant, resonant frequency and electrostatic force of a comb actuator but it increases the displacement of the mass. Among the three structures, the comb actuator with double crab-leg support beams is more influenced by anisotropy variation in RIE etch than other two.

  • PDF

Digital Blood Pressure Estimation with the Differential Value of the Arterial Pulse Waveform (맥파의 차동값에 의한 디지털 방식의 혈압 추정 기법)

  • Kim, Boyeon;Chang, Yunseok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.6
    • /
    • pp.135-142
    • /
    • 2016
  • We proposed the new method to estimate the blood pressure with the differential value of the digital arterial pulse waveform and BP relation equation. To get the digital arterial pulse waveform, we use the arterial pulse waveform measurement system that has digital air-pressure sensor device and smart phone. The acquired digital arterial pulse waveforms are classified as hypertension group, normal group, and hypotension group, and we can derive the average differential value between the highest point and lowest point of a single waveform of individuals along with the group. In this study, we found the functional correlation between the blood pressure and differential value as a form of BP relation equation through the regression process on the average of differential value and blood pressure value from a tonometer. The Experimental results show the BP relation equation can give easy blood pressure estimation method with a high accuracy. Although this estimation method has over 66 % error rate and does not give the high level of the accuracy for the diastolic compares to the commercial tonometer, the estimation results for the systolic show the high accuracy that has less than 10 % error rate.

Soil Organic Carbon Determination for Calcareous Soils (석회암 유래 토양의 토양유기탄소 분석법 연구)

  • Jung, Won-Kyo;Kim, Yoo-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.6
    • /
    • pp.396-402
    • /
    • 2006
  • Soil organic carbon has long been considered as the most critical factor to evaluate the soil quality, fertility, and fertilizer prescription. In addition, soil organic carbon may impact on greenhouse gas effects and global warming. Because of that, the management of soil organic carbon is increasingly important not only for improving soil quality but also for managing soil as a greenhouse gas source. Both wet and dry combustion have been used to determine soil organic carbon. Many benefits, such as automation and less labor, could the dry combustion method become more popular. Inorganic form of carbon could overestimate soil organic carbon when the dry combustion method was applied. Determination of soil inorganic carbon may contribute to the improved accuracy of soil organic carbon analysis using dry combustion method. Objectives of this research were 1) to develop soil inorganic carbon determination method using modified digital pressure calcimeter and 2) to evaluate soil organic carbon from calcareous soils using the dry and wet combustion method. Results showed that the significant linear relationship was found between soil inorganic carbon content and pressure calcimeter output. Inorganic carbon ranged from 22% to 28% of total carbon in the calcareous soil samples. Soil organic carbon content by dry combustion for calcareous soil was determined by subtracting inorganic carbon measured by the digital pressure calcimeter from total carbon. Soil organic carbon determined by dry combustion method was significantly correlated with that by wet combustion method. In conclusion, the digital pressure calcimeter may use to improve soil organic carbon determination for the calcareous soils by subtracting of soil inorganic carbon from total carbon determined by dry combustion method.

Characteristics of Suspended Fine-Grained Particles in Settling Columns (침강수주에서 부유된 광물성 미립자의 특성)

  • Kim Jong-Woo;Yoon Sei-Eui;Lee Jong-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.393-398
    • /
    • 2005
  • Suspended fine mineral particles are deposited at the areas with low flow velocity and low transportation capacity in rivers, reservoirs and lakes. It can be contaminated by heavy metals. Examples of problem fields art dredging of sediment, water pollutants, and maintenance of navigation channels and construction works. To deal with the settling problems it is necessary to understand tile physico-chemical characteristics of cohesive sediment under varying density of particle and ion addition(NaOH, HCl, NaCl), which is dissolved in river, because fine-grained cohesive sediment can lead to flocculation with the physico-chemical influences and takes different characteristics. Experiments with fresh and saline water are followed with fine-grained sediments(alumina and quartz) in settling columns. Settling velocity of suspended fine particles in still water was measured with a pressure sensor(maximum 10 mbar). Until the initial concentration of 20,000 mg/1 of alumina and quartz the settling velocity was on the increase. Above this initial concentration was it on the decrease. In an acid condition, which causes strong flocculation, average settling velocity of quartz powder was high. In an alkaline water low average settling velocity of it was observed. However, alumina behaved exactly contrarily.

  • PDF

Experiment on Settling Velocity of Suspended Mineral Particles (부유된 광물성 입자의 침강 속도에 관한 실험)

  • Kim, Jong-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.9
    • /
    • pp.723-734
    • /
    • 2007
  • This study was to investigate the settling velocity which is an important factor for the prediction of cohesive deposition under the various densities of particle and dissolved ion addition$(Na^+,\;Cl^-,\;OH^-,\;H^+)$ in rivers, ports, reservoirs and lakes. Settling velocity of suspended fine particles in still water was measured with a pressure sensor (maximum 10 mbar). At the initial concentration of 20g/l of alumina and quartz the average settling velocities were high due to the aggregation behaviour of particles. At this point it was 0.185 mm/s (alumina) and 0.022 mm/s (quartz). Above this initial concentration it was on the decrease owing to the hindered settling. The higher the salinity is, the faster the settling velocity of alumina and quartz is. Furthermore, in an acid condition the average settling velocity of alumina was on the decrease. In an alkaline water, which causes strong flocculation, the average settling velocity of alumina it was observed on the increase. However, in an alkaline medium the low average settling velocity of quartz powder was measured.

The Wireless Monitoring System of Respiration Signal (호흡신호 무선 통신 시스템 개발)

  • Son, Byoung-Hee;Jang, Jong-Chan;Yang, Hyo-Sik;Cha, Eun-Jong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.3
    • /
    • pp.157-162
    • /
    • 2011
  • This study is about implementing wireless transferring system in pre-hospital cardiopulmonary resuscitation(CPR). Also, this study includes monitoring based feedback between patient and hospital to increase the survival rate of emergency patient by developing the performance of cardiopulmonary resuscitation in pre-hospital. It minimizes the loss of flow rate or gastric inflation through the space between the airway and the esophagus, which enables the inspiration-expiration rate to be measured more precisely. Due to these reasons this study applied ET insertion based respiratory sensor to measure flow rate. The main indices of artificial ventilation are justified from minute respiration(V), end-tidal $CO_2(E_TCO_2)$, and tracheal pressure($P_{tr}$). The simulation is performed to verify the bandwidth and delay time of transport network for in-hospital monitoring even as transporting images and voice information simultaneously. The total bandwidth is 815 kbps, and WLAN (IEEE 802.11x) is used as communication protocol. The network load is under 1.5% and the transmit delay time is measured under 0.3 seconds.

Development of Hovering AUV 'NOAH' Test-bed for Underwater Explorations (수중탐사용 호버링 무인잠수정 NOAH의 테스트베드 개발)

  • Byun, Seung-Woo;Kim, Joon-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.414-419
    • /
    • 2010
  • This paper describes the design and performance of a hovering AUV 'NOAH' constructed at Jeju National University. We analyse the dynamic performance of NOAH using simulation program and carry out depth control test at small basin. The main purpose of NOAH is to carry out fundamental tests on its attitude control and position control. Its configuration is similar to general ROV appearance for underwater works and dimension is $0.75m{\times}0.5m{\times}0.5m$. It has 4 thrusters of 450watt for longitudinal/lateral/vertical propulsion and is equipped with a pressure sensor for measuring water depth and a magnetic compass for measuring heading angle. The navigation of the vehicle is controlled by an on-board Pentium III-class computer, which runs with the help of the Windows XP operating system. These give us an ideal environment for developing various algorithm which are needed for developing and advanced hovering AUV.

TPMS Interference Suppression Based on Beamforming (Beamforming을 이용한 TPMS 간섭제거)

  • Hwang, Suk-Seung;Kim, Seong-Min;Park, Cheol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.180-185
    • /
    • 2011
  • The TPMS(Tire Pressure Monitoring System) is an electronic system designed to display the air pressure inside the pneumatic tires and report real-time tire-pressure information to the driver of the vehicle, either via a gange, a pictogram display, or a simple low-pressure warning light. Although the data measured by TPMS sensor is transmitted to internal signal processer in a vehicle through wireless communication, the receiver may suffers from various interferences such as amateur radio station, RFID(Radio-Frequency IDentification) for controlling container, RKE(Remote Keyless Entry) signal, and so on. In this paper, we consider beamforming technology to suppress various high-power interference signals for the TPMS wireless communications. Also, we propose the proper data structure and antenna arrangement for the beamformer inside the vehicle. The performance for the interference suppression is illustrated by computer simulation example.

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF