• Title/Summary/Keyword: 아르키메데스

Search Result 53, Processing Time 0.027 seconds

The study of thermal properties of graphene/Cu foam hybrid structures (그래핀/구리폼과 그래파이트 하이브리드 구조체의 열전도 특성 연구)

  • Kim, Hee Jin;Kim, Hyeungkeun;Kim, Yena;Lee, Woo Sung;Yoon, Dae Ho;Yang, Woo Seok
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.5
    • /
    • pp.235-240
    • /
    • 2013
  • Pure-carbon materials such as graphite, graphene, carbon nanotubes, and diamond have very high thermal conductivities. The reported thermal conductivity of graphene is in the range 3000~5000W/m-K at room temperature. Here, we developed graphene/cu foam hybrid type heat spreader to obtain higher thermal conductivity than Cu foam. Hybrid materials were characterized using optical microscopy (OM), scanning electron microscopy (SEM) and thermal conductivity measurement system; LFA (Laser Flash Analysis @ LFA 447, NETZSCH). We suggest that excellent thermal properties of graphene/cu foam hybrid structures are beneficial for all proposed electrical applications and can lead to a thermal management application.

Accurate Measurement of the Thermal Conductivity of Electronic Materials Using the Flash Method (섬광법을 이용한 전자재료의 열전도율 정밀측정)

  • Kim, Seog-Kwang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.9-9
    • /
    • 2008
  • 일반적으로 섬광법으로 열전도율을 구하기 위해서는 섬광법으로 열확산계수를 측정하고, 시차주사열량계(Differential Scanning Calorimetry, DSC)로 비열측정을 하며 아르키메데스의 원리를 이용한 용적밀도를 구하여 이들 각각의 값을 사용하여 열전도율을 얻는다. 따라서 열전도율을 정밀하게 측정하기 위해서는 이 세 가지 물성치를 측정할 때 수반되는 오차요인을 종합적으로 검토하여 개선하는 것이 매우 중요하다. 섬광법으로 열확산계수를 측정할 때 시료의 전면에 조사되는 빛의 흡수율을 향상시키고 배면에서의 온도상승의 감지를 증대할 목적으로 시료 양면에 흑연코팅을 하게 된다. 이때 코팅된 흑연이 시료에 부가적으로 열저항을 증가시켜서 열확산계수를 측정하는데 가장 큰 오차요인이 되고 있다. 한편 비열은 대부분 DSC로 측정하는데, 시료와 용기의 열접촉 정도에 따라 큰 오차요인이 되기도 한다. 본 연구에서는 열확산계수를 정밀하게 측정하기 위해서 시료에 부가적인 열저항으로 작용하는 흑연코팅의 두께와 시료배면에서의 온도상승곡선 간의 상관관계를 실험식으로 도출하였으며 이방법은 열확산계수를 정밀하게 측정하는데 매우 유효한 방법임이 입증되었다. 또한 DSC의 접촉에서의 문제점을 해결하기 위해서 시료배면에서의 무차원 시간축(t/$t_{max}$)을 도입하였으며. 무차원 시간축에 따른 온도상승 곡선에서 표준시료와 측정시료의 half time($t_{1/2}$)의 0.5 배와 1.5배 사이 구간을 적분한 뒤 비교하여 열량계산으로부터 비열을 구하는 방법을 새롭게 개발하였으며 기존의 DSC에 비하여 정밀도를 향상시킬 수 있었다. 결론적으로 새롭게 제안된 측정기법들은 열확산계수 및 비열 혹정 시의 근본적인 오차요인을 혁신적으로 해결함으로써 정밀하고 신뢰성 있는 열전도율을 측정할 수 있음을 입증할 수 있었다.

  • PDF

Design of the 1/8 Scaled HU-KINS Based on the Scaling Laws for the Experimental Investigation of Thermal-Hydraulic Effect of CANDU-6 Moderator (CANDU-6 원자로 감속재 열수력 개별영향실험을 위한 축소화 기법에 따른 1/8 축소형 HU-KINS 설계)

  • Lee, Jae-Young;Kim, Man-Woong;Kim, Nam-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.825-833
    • /
    • 2006
  • To investigate the moderator coolability for CANDU-6 reactors, a test facility (HU-KINS) has been manufactured as a 1/8 scaled-down of a calandria tank. In the design of the test facility, a scaling law was developed in such a way to consider the thermal-hydraulic characteristics of a CANDU-6 moderator. The proposed scaling law takes into consideration of the energy conservation, the dynamic similitude such as dimensionless numbers, Archimedes number (Ar) and Reynolds number (Re), and thermal-hydraulic properties similitude. Using this proposed scaling law, the thermal-hydraulic scaling analyses of similar test facilities such as the SPEL (1/10 scale) and the STERN (1/4 scale), have been identified. As a result, in the case of the SPEL, while the energy conservation is well defined, the similarities of Ar and the heat density are not well considered. As for the similarity of the STERN, while both the energy conservation and the characteristics of Ar are well defined, the heat density is not. In the meanwhile, the HU-KINS test facility with 1/8 length scaled-down is well similitude in compliance with all similarities of the energy conservation, the fluid dynamics and thermal-hydraulic properties. To verify the adequacy of the similarities in terms of thermal-hydraulics, a computational fluid dynamic (CFD) analysis has been conducted using the CFX-5 code. As the results of the CFD analyses, the predicted flow patterns and variation of axial properties inside the calandria tank are well consistant with those of previous studies performed with FLUENT and this implies that the present scaling method is acceptable.

A History of Calculus and the Dialectical Materialism (미적분의 역사와 변증법적 유물론)

  • 조윤동
    • School Mathematics
    • /
    • v.5 no.4
    • /
    • pp.521-540
    • /
    • 2003
  • The processes of mathematics development and the results of it are always those of making a conquest of the circumscription by historical inevitability within the historical circumscription. It is in this article that I try to show this processes through the history of calculus. This article develops on the basis of the dialectical materialism. It views the change and development as the facts that take place not by individual subjective judgments but by social-historical material conditions as the first conditions. The dialectical materialism is appropriate for explaining calculus treated in full-scale during the 17th century, passing over ahistorical vacuum after Archimedes about B.C. 4th century. It is also appropriate for explaining such facts as frequent simultaneous discoveries observed in the process of the development of calculus. 1 try to show that mathematics is social-historical products, neither the development of the logically formal symbols nor the invention by subjectivity. By this, I hope to furnish philosophical bases on the discussion that mathematics teaching-learning must start from the real world.

  • PDF

Polymerization Shrinkage and Stress of Silorane-based Dental Restorative Composite (Silorane-기질 치아 수복용 복합레진의 중합수축과 중합수축응력)

  • Lee, In-Bog;Park, Sung-Hwan;Kweon, Hyun-Jeong;Gu, Ja-Uk;Choi, Nak-Sam
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.182-188
    • /
    • 2013
  • The purpose of this study was to measure the volumetric polymerization shrinkage kinetics and stress of a silorane-based dental restorative composite and compare it with those of conventional methacrylate-based dental composites. Two methacrylate-based composites (Z250, Z350 flowable) and one silorane-based composite (P90) were investigated. The volumetric polymerization shrinkage of the composites during light curing was measured using a laboratory-made volume shrinkage measurement instrument based on the Archimedes' principle, and the polymerization stress was also determined with the strain gage method. The shrinkage of silorane-based composites (P90) was the lowest, and that of Z350 flowable was the highest. Peak polymerization shrinkage rate was the lowest in P90 and the highest in Z350 flowable. The time to reach peak shrinkage rate of P90 was longer than those of the methacrylate-based composites. The polymerization shrinkage stress of P90 was lower than those of the methacrylate-based composites.

Teachers' Perceptions of Explanatory Method Based-on Process Viewpoint for Floating and Sinking Phenomena (뜨고 가라앉는 현상에 대한 과정적 관점 설명방식에 대한 교사들의 인식)

  • Kim, Sungki;Paik, Seoung-Hye
    • Journal of The Korean Association For Science Education
    • /
    • v.40 no.6
    • /
    • pp.583-594
    • /
    • 2020
  • In this study, the existing concept of density has a limitation in providing the cause of phenomena, and the concept of buoyancy poses a problem because it has many misconceptions and requires an overly difficult concept to understand quantitative calculation, so we suggest an explaining method as process viewpoint introducing the principle of lever. The new method of explanation has been proposed using the lever as visual tool to reveal the gravity as the fundamental principle and process viewpoint. As a result, teachers stayed on many alternative concepts and less than half of the teachers were aware that density was related to gravity. In addition, they recognized it as matter viewpoints, but there is a meaningful conceptual change after intervention(p<.000). Also, they evaluated that the new method is better able to recognize the principle and process viewpoint than the existing description method. Through this, we can confirm the educational value of explaining method as process viewpoint introducing the principle of lever.

A Fabrication of an Angle Trisection Tool Using Veprtskii's Method (Veprtskii의 방법을 활용한 각의 삼등분 도구 제작)

  • Han, Inki
    • Communications of Mathematical Education
    • /
    • v.36 no.4
    • /
    • pp.627-644
    • /
    • 2022
  • In this study various angle trisection tools based on Archimedes' insertion method were investigated, some tools were fabricated and their characteristics were compared. Through these works, it was found that factors such as the convenience of use, arbitrariness of the trisected angle, and simplicity of structure should be considered in the production and utilization of the trisection tool. Considering the factors described above, attention was paid to the method proposed by Veprtskii A.I. in 1888 as a making method of the angle trisection tool. In this study, we improved the method proposed by Veprtskii A.I., we used two wooden chopsticks and a string to make an angle trisection tool. The improved trisection tool had fewer parts than other trisection tools, a simple structure, and more convenient usage. In particular, this tool divided an arbitrary angle(not a specific angle) into the same three parts, and the production cost was low and the production process was simple. This tool is expected to be widely used in concrete activities related to the properties of the exterior angles of triangles and the properties of isosceles triangles in mathematics classrooms.

POLYMERIZATION SHRINKAGE KINETICS OF SILORANE-BASED COMPOSITES (Silorane 복합레진의 중합수축의 동력학)

  • Kwon, Young-Chul;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.1
    • /
    • pp.51-58
    • /
    • 2010
  • Dental composites have improved significantly in physical properties over the past few decades. However, polymerization shrinkage and stress is still the major drawback of composites, limiting its use to selected cases. Much effort has been made to make low shrinking composites to overcome this issue and silorane-based composites have recently been introduced into the market. The aim of this study was to measure the volumetric polymerization shrinkage kinetics of a silorane-based composite and compare it with conventional methacrylate-based composites in order to evaluate its effectiveness in reducing polymerization shrinkage. Five commercial methacrylate-based (Beautifil, Z100, Z250, Z350 and Gradia X) and a silorane-based (P90) composites were investigated. The volumetric change of the composites during light polymerization was detected continuously as buoyancy change in distilled water by means of Archemedes' principle, using a newly made volume shrinkage measurement instrument. The null hypothesis was that there were no differences in polymerization shrinkage, peak polymerization shrinkage rate and peak shrinkage time between the silorane-based composite and methacrylate-based composites. The results were as follows: 1. The shrinkage of silorane-based (P90) composites was the lowest (1.48%), and that of Beautifil composite was the highest (2.80%). There were also significant differences between brands among the methacrylate-based composites. 2. Peak polymerization shrinkage rate was the lowest in P90 (0.13%/s) and the highest in Z100 (0.34%/s). 3. The time to reach peak shrinkage rate of the silorane-based composite (P90) was longer (6.7 s) than those of the methacrylate-based composites (2.4-3.1 s). 4. Peak shrinkage rate showed a strong positive correlation with the product of polymerization shrinkage and the inverse of peak shrinkage time (R = 0.95).

Fruit Quality Characteristics and Pithiness Tissue Occurrence with Fruit Gravities in 'Niitaka' Pear Fruit ('신고' 배의 비중에 따른 과실 품질 특성과 바람들이 발생)

  • Cho, Joon-Shik;Kim, Wol-Soo;Lee, Sang-Hyun
    • Horticultural Science & Technology
    • /
    • v.28 no.4
    • /
    • pp.545-551
    • /
    • 2010
  • The primary objective of this study was to determine the relationship between fruit quality characteristics and pithiness fruit occurrence for confirming occurrence factors of pithiness tissues in 'Niitaka' pears ($Pyrus$ $pyrifolia$ Nakai). Fruits were harvested 4 times in 1 week intervals from 160 days after full bloom (DAFB) to 181 DAFB. Harvested fruits were separated with the specific gravity by Archimedes laws. Also, with specific gravity level in pear fruit, sugar content, acidity, and texture profile analysis (TPA) were investigated. Final verifiability of pithiness fruit was approved by eye observation at 90 days after storage. Also, in ASS (Alcohol Soluble Solid) and AIS (Alcohol Insoluble Solid), calcium contents were investigated. Although the differences in sugar and organic acid content were not significant in fruits divided by gravity, flesh hardness was depressed in fruits that showed low gravity. These results were more conspicuous in late harvested fruits (at 174 and 181days after full bloom) which showed low gravity, representing less content of AIS content and calcium in ASS and AIS when compared with early harvest fruits. Fruits of lower gravity below 1.0 measured with dipping induced the progression of pithiness symptom up to 76%. Consequently, harvest timing is a more concise factor in pithiness fruit occurrence although those symptom also affected by storage condition. Furthermore, the cause of pithiness fruit occurrence by late harvest is due to the lower cell wall binding calcium.

Evaluation of Methods Used in the Calculation of Condition Index Using the Mussel, Mytilus coruscus (Gould, 1861) Collected from Chuja Island, Cheju, Korea (추자도산 홍합, Mytilus coruscus (Gould, 1861) 의 Condition Index 산정에 대한 연구)

  • 강도형;최광식
    • The Korean Journal of Malacology
    • /
    • v.15 no.1
    • /
    • pp.57-62
    • /
    • 1999
  • Condition indices (Cl) are considered to be useful measurements of the nutritive and health status of bivalves although studies on Cl of bivalves are limited due to the lack of a standard formula for calculating Cl. This study attempts to generate Cl of the mussel, Mytilus coruscus inhabiting along the coastal area of Chuja Island in Cheju using three primary formulas. the formulas used in this study: (1) Cl-vol= [tissue dry weight (g) 1000] /shell cavity volume (ml). (2) Cl-wt= [tissue dry weight (g) 1000] / internal shell cavity capacity (g). (3) Cl-size= tissue wet weight (g)/[shell length (mm)]$\^$3/. Monthly condition indices calculated with the three formulas are compared using ANOVA, Duncan's multiple range test and Pearson correlation coefficient. In Chuja Island M. coruscus collected ranged from 50 to 180 mm in shell length. Monthly ranges of Cl-values were 67.48 to 140.61 (Cl-vol), 74.67 to 118.02 (Cl-wt) and 1.4 10$\^$-5) to 1.6 10$\^$-5/ (Cl-size). Cl-vol values in August were higher than two Cl-values in the other months. Monthly Cl-vol was significantly different from Cl-wt and Cl-size. (p<0.05). The results of this study suggest that volumetric condition index (Cl-vol) used in this study is acceptable as a standard measure to evaluate conditions of M. coruscus.

  • PDF