• Title/Summary/Keyword: 실증설비

Search Result 336, Processing Time 0.026 seconds

Study on the Risk Management of the CERs Investment - Regarding Registration Risks and Price Change Risk in Investing Primary CERs - (탄소배출권 투자와 위험관리방안 연구 - 일차배출권(Primary CER) 투자 시 등록위험 및 가격변동 위험을 중심으로 -)

  • Lee, Chang Seok;Kim, Yun Soung;Jeon, Eui Chan
    • Journal of Climate Change Research
    • /
    • v.2 no.2
    • /
    • pp.115-131
    • /
    • 2011
  • Out of all the possible actions that can be taken to respond to greenhouse gas reduction, including development of greenhouse gas reduction technology, infrastructure, actions to improve energy saving and efficiency, and offset with carbon emission reductions (CERs), this study shall focus on the investment on CERs. This study will take a look at risks involved with investing in CERs such as UN registration refusal risk and CERs price fluctuation, and will design risk management model which shall be verified. The goal of this paper is to provide optimized CERs investment strategies for different types of investors, such as general trading companies seeking for investment opportunities and financial companies with plans for green products development and investment by preparation for carbon market. It is expected that the global competitiveness of domestic financial companies shall be improved by taking actions on carbon market instead of previous passive response to climate change and that Korea, the number two Carbon Emissions supplier and number one derivatives market in terms of volume, shall be able to lead the worldwide carbon market.

Numerical Analysis of Flow Characteristics in an Injection Tubing during Supercritical CO2 Injection: Application of Demonstration-scale CO2 Storage Project in the Pohang Basin, Korea (초임계 상태의 CO2 주입시 주입관내 유동 특성의 수치해석적 연구: 포항분지 중소규모 CO2 지중저장 실증 사업에 적용)

  • Jung, Woodong;Sung, Wonmo;Han, Jeongmin;Song, Youngsoo;Wang, Jihoon
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.9-17
    • /
    • 2022
  • This paper is the continuation of our previous paper, which we refer to as numerical analysis of phase behavior and flow properties in an injection tubing during gas phase CO2 injection. Our study in this paper show the results during supercritcal CO2 injection under the same project. Geological CO2 storage technology is one of the most effective method to decrease climate change due to high injectivity and storage capacity and economics. A demonstration-scale CO2 storage project was performed in a deep aquifer in the Pohang basin, Korea for a technological development in a large-scale CO2 storage project. A problem to consider in the early stage design of the project was to analyze CO2 phase change and flow characteristics during CO2 injection. To solve this problem, injection conditions were decided by calculating injection rate, pressure, temperature, and thermodynamic properties. For this research, we simulated and numerically analyzed CO2 phase change from liquid to supercritical phase and flow characteristics in injection tubing using OLGA program. Our results provide discharge pressure and temperature conditions of CO2 injection combined with a pressure of an aquifer.

Comparison of LCOE of the Southwest Offshore Wind Farm According to Types and Construction Methods of Supporting Structures (해상풍력 지지구조물 형식 및 시공 방법에 따른 서남해 해상풍력실증단지의 균등화발전비용 비교)

  • SeoHo Yoon;Sun Bin Kim;Gil Lim Yoon;Jin-Hak Yi
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.3
    • /
    • pp.57-66
    • /
    • 2023
  • In order to understand the economic feasibility of an offshore wind farm, this paper analyzed the differences in LCOE (levelized cost of energy) according to the support type and construction method of the substructure in terms of LCOE and sensitivity analysis was conducted according to the main components of LCOE. As for the site to be studied, the Southwest Offshore Wind Farm was selected, and the capital expenditures were calculated according to the size of the offshore wind farm and the installation unit. As a result of the sensitivity analysis, major components showed high sensitivity to availability, turbine related cost, weighted average cost of capital and balance of system related cost. Moreover, the post-piling jacket method, which was representatively applied to the substructure of the offshore wind farm in Korea, was selected as a basic plan to calculate the capital expenditures, and then the capital expenditures of the pre-piling jacket method and the tripod method were calculated and compared. As a result of analyzing the LCOE, it was confirmed that the pre-piling jacket method of the supporting structure lowers the LCOE and improves economic feasibility as the installation number of turbines increases.

An Empirical Study of Hot Water Supply Patterns and Peak Time in Apartment Housing with District Heating System (공동주택의 급탕부하 지속시간 및 부하 패턴에 관한 실증연구)

  • Kim, Sung-Min;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.21 no.4
    • /
    • pp.435-443
    • /
    • 2012
  • The combination of space shortage and the high population density concentrated in urban areas of South Korea has resulted in the growth of large-scale high-rise residential complexes, naturally affecting water and hot water usage patterns as well. But the current designs for water and hot water supply in South Korea rely mostly on international design standards and data calculated on site due to the severe shortage of basic data in relation to actual use, which result in the frequent problem of the under-or over-design of water and hot water supply. The following study measures the hot water supplier's conditions and the user's heat usage to realize the amount of time required for hot water supply load generation and the pattern of actual use in order to create basic data for effective hot water supply facility design and maintenance.

An Evaluation of Energy Quality for Distributed Powersystem (분산형 발전설비 병열운전 에너지 품질평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Yoon, Gi-Gab;Rhim, Sang-Kyu;Choi, In-Kyu
    • Journal of Energy Engineering
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • As environmental friendly energy system, distributed micro gasturbine is focused on new energy source for overcoming brand new construction area of power generation. This distributed micro gasturbine system has the powerful characteristics as belows; 1) environmental friendly features NOx < 9 ppm, noise < 65 db 2) various fuel flexbility which is used such as natural gas, diesel, low calory new & renewable fuel, kerosene. 3) high specific output power based on small area and is avilable for very easy and compact installation. There are many new installation sites in USA and Japan from 1998. On the other hand the exhisting large power system was constructued by the sea side, this compact power system is now installed by enduser in downtown area and supplying combined heat & power, has the various apllication on-site power generation. In recently, there is the very important issue for new & reliablbe energy development and spreading out. This paper represent as belows for important system characteristics; 1) grid connection modeling 2) system operation characteristics 3) on-site operation result and evaluation output of power quality analysis.

The Impacts of External and Internal Environmental Factors on External Collaboration-From the Perspective of Foreign Direct Investment (기업환경요인이 협력활동에 미치는 영향에 관한 실증연구 -해외직접투자 여부에 따른 비교-)

  • Lee, Seung A
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.1
    • /
    • pp.132-142
    • /
    • 2018
  • This study attempts to identify the external and internal factors which affect collaboration motives and investigates their respective impacts from the perspective of foreign direct investment(FDI). Although there has been much research on collaboration motives, so far, few studies have associated collaboration motives with FDI. The findings suggest that while price competitiveness and cost structure uncertainty have a positive and significant impact on collaboration motives, the gross added value to property as well as plant and equipment have a significant negative impact. Furthermore, in the case of gross added value to both property and plant and equipment, managers tend to collaborate with others to enhance the value of these factors. For both FDI and non-FDI firms, internal factors such as price competitiveness and investment within three years are significant determinants for the decision to collaborate. The difference between FDI and non-FDI firms is that for the former, the gross added value to property, an internal factor, is a critical factor, while for the latter, the cost structure uncertainty, an external factor, is critical for collaboration. To summarize, this study suggests the following managerial implication: the enhancement of the internal competency of a firm broadens the window of opportunity for collaboration with others, and consequently provides a chance to boost management efficiency.

A Study on Reduction of Nitrogen Oxide (NOx) and Stability of Incineration Facility by the Food Wastewater Incineration (음식물류 폐수 소각처리에 따른 질소산화물 저감 및 소각설비의 안정성 평가에 관한 연구)

  • Hwang, Seung-Min;Chung, Jin-Do;Song, Jang-Heon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.901-908
    • /
    • 2009
  • We examine the processing method of the food wastewater to direct spray at living waste incinerator. The demoscale stoker system is used as a incineration facility. The results show that it brings effect on the reduction of nitrogen oxide ($NO_x$) concentration as well as the ammonia ($NH_3$) amount in SNCR (selective non-catalytic reduction) by the incineration of food wastewater which is containing a plentiful ammoniac nitrogen ($NH_3$-N). Furthermore, the stability of incineration facility and the extension of operation period is actualized as a improvement of clogging phenomenon on outer wall of water pipe as the 870~$950^{\circ}C$ maintain of exit temperature in a second combustor by spray of the food wastewater. The 26 items of air pollution matter of nitrogen oxide ($NO_x$), sulfur oxide ($SO_x$) and dioxin etc. are measured. The results show that it is under the value of allowable exhaust standard.

A Study on the Destruction or Removal Efficiency of Toxic Gas Reduction Facilities in Semiconductor and Display Industries (반도체 & 디스플레이 업종에서 사용되는 독성가스 저감시설의 처리효율 측정방법에 관한 연구)

  • Jang, Sung-Su;Han, Jae-Kook;Cho, Hyun-Il;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.88-95
    • /
    • 2017
  • The usage of toxic gas in Korea is increasing in the development of high-tech industries such as semiconductors, displays and solar panels. The recent survey of domestic toxic gas consumption indicates an increase in annual average of 12.4 percent, but it is still focused on usage, and it is negligent in safety and treating the post. In September 2012, an accident occurred in Gu-mi involving hydrofluoric acid leak demonstrates the absence of safety management. Due to the incident, the government, industry and academia have been interested in chemical substances(toxic gas), and the government-led safety management has been established and implemented, but there are still a lot of safety blind spots. The purpose of this study is to develop effective measurement methods for the destruction or removal efficiency of gaseous materials emitted from the Scrubber used in the semiconductor and display industries. Also, this study demonstrated how toxic gas facilities can be applied without error by verification test for the measurement method guideline of the destruction or removal efficiency of the green-house gas reduction facility in the semiconductor and display industries used by the National Institute of Environmental Research and the UNFCCC, and suggested the differentiated measurement methods for toxic gas reduction facilities, and the third party certification for safety facilities is needed to prevent toxic gas accidents.

A Prediction of Coal Ash Slagging for Entrained Flow Gasifiers (분류층 석탄가스화기 Slag 용융특성 예측)

  • Koo, Jahyung;Kim, Bongkeum;Kim, Youseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.108.1-108.1
    • /
    • 2010
  • 분류층 가스화기는 석탄과 산소(공기) 및 수증기가 반응하여 $1200{\sim}1600^{\circ}C$의 고온, 20~60기압의 고압에서 작동되어 합성가스를 생성하며 합성가스에 포함된 입자 및 황화합물 등을 정제설비를 통하여 정제 후 발전 및 화학원료로 사용한다. 석탄가스화 중 석탄에 포함된 대부분의 회분은 용융슬래그 형태로 가스화기 벽면을 따라 흘러 내려 가스화기 하부의 냉각수조에서 급랭되어 배출된다. 이때 용융슬래그의 원활한 배출을 위해서는 일정범위의 점도를 유지하는 것이 필요하다. 슬래그의 점도는 가스화기 온도 및 Ash의 조성에 따라 크게 변하며 가스화기 설계 및 운전 시 매우 중요한 변수이다. 따라서 최적의 설계 및 운전을 위해서는 Ash의 점도예측이 중요하며, 분류층 가스화기내부에서 Ash 점도 예측을 위한 DooVisco 프로그램을 개발하였다. DooVisco는 가스화기 내부에서 슬래그 용융온도 및 온도별 점도, 가스화기 최소 운전온도 및 석회석 투입 효과 분석뿐만 아니라 석탄의 혼합 사용 시의 특성 예측도 가능하도록 개발되었다. DooVisco는 슬래그 주요 4성분인 SiO2, Al2O3, CaO, FeO 성분에 대한 Phase Diagram을 이용하여 1차적으로 슬래그용융온도(Liquidus Temperature)를 예측하고, 주요 4 성분 외에 Na2O, MgO, K2O, TiO2 등을 고려한 Kalmanovich Model을 이용하여 점도를 예측한다. 최종적으로 슬래그 용융온도와 점도를 활용하여 분류층 가스화기 운전가능 온도범위를 예측한다. 개발된 DooVisco를 활용하여 300MW급 실증 IGCC 플랜트에 사용가능성이 있는 석탄을 대상으로 슬래그의 용융온도 및 점도 등을 예측하였으며 최적 운전을 위한 슬form점도 조절용 Flux인 석회석 투입량 등을 평가하였다. 평가 결과 슬래그 용융온도가 $1700^{\circ}C$ 이상으로 석회석 투입이 필요하다고 판단되었다. 약 가스화기 내부 온도를 $1500^{\circ}C$ 정도에서 원활한 운전을 위해서는 석탄 대비 약 10% 내외의 석회석 투입이 필요할 것으로 평가되었다. DooVisco는 분류층 가스화기 설 계시 가스화기 최적 운전 온도 설정 및 Flux 투입필요성, 종류, 투입량 선정에 활용될 수 있을 뿐만 아니라 플랜트 운전시 석탄의 탄종 적합성 등을 판단하는데 활용될 수 있을 것이라 판단된다.

  • PDF

Development of process for energy recovery from landfill gas using LFG-Hydrate (LFG-Hydrate를 통한 매립가스 에너지화 공정 개발)

  • Moon, Donghyun;Shin, Hyungjoon;Han, Kyuwon;Lee, Jaejung;Yoon, Jiho;Lee, Gangwoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.152.2-152.2
    • /
    • 2010
  • LFG는 매립된 폐기물 중 유기성분이 혐기성조건에서 미생물에 의해 분해가 되면서 발생하며, 이러한 매립지가스는 주변 지역의 자연 및 생활환경에 악영향을 미치기 때문에 소각 등의 방법으로 LFG를 처리하고 있다. 일반적으로 매립지로부터 발생하는 가스의 량은 폐기물 1톤 당 $150{\sim}250m^3$로서 매립 후 2~3년 후에 최대량이 발생하며 매립 후 20~30년 후까지 지속적으로 발생함으로 안정적인 LFG의 공급이 가능하며, 메탄함량이 50%인 경우 약 $5,000kcal/m^3$의 높은 발열량을 가지므로 대체에너지원으로 이용할 경우 환경적인 문제 해결 및 신재생에너지원으로 활용할 수 있다. LFG 자원화 할 경우 가장 안정적인 방안으로 발전 및 중질가스로 활용하는 것이나, 발전의 경우 최소 200만톤 이상의 매립용량을 갖추어야 경제적인 사업성을 확보할 수 있으며, 중질가스로 활용하는 경우 인근에 가스 수요처를 확보해야 하는 어려움이 있다. 만약 중 소규모의 매립장에서 발생하는 LFG를 안전하고 경제적인 조건으로 저장 및 수송할 수 있다면 중 소규모의 매립지에서 발생하는 LFG도 활용할 수 있을 것으로 기대되며, 안전하고 경제적인 저장과 수송기술을 통하여 발전이 아닌 중질가스로의 활용도 가능하게 될 것이다. 또한 여러 곳의 매립장에서 발생한 LFG를 한 곳으로 집중시켜 고질가스로 전환하는 설비비용을 절감할 수 있으며, 정제된 고질가스를 이용하여 발전보다 경제적인 자동차 연료나 도시가스로 활용할 수 있을 것이다. 본 연구에서는 LFG의 저장과 수송기술 중 GTS 기술을 통하여 저장과 수송에 제약이 크고 많은 비용이 소비되는 기체 상태의 에너지원을 하이드레이트화 시킴으로서 중 소규모 매립지에서 상대적으로 적은 비용으로 가스저장과 지상수송이 가능하게 할 수 있다. 본 연구의 결과로 LFG 에너지화 실증화 플랜트를 설계/제작 하였으며, 메탄+이산화탄소+물 하이드레이트 형성 실험 결과 4.56 Mpa, 277.2 K 조건에서 3시간을 한 사이클로 하는 공정운전을 가지는 것을 확인하였다. 이때 생성된 슬러리상의 하이드레이트를 고압으로 배출하여 펠릿으로 형성시켰으며, 형성된 하이드레이트 펠릿의 경우 92.27%의 메탄을 포함하는 것을 확인하였다.

  • PDF