Abstract
We examine the processing method of the food wastewater to direct spray at living waste incinerator. The demoscale stoker system is used as a incineration facility. The results show that it brings effect on the reduction of nitrogen oxide ($NO_x$) concentration as well as the ammonia ($NH_3$) amount in SNCR (selective non-catalytic reduction) by the incineration of food wastewater which is containing a plentiful ammoniac nitrogen ($NH_3$-N). Furthermore, the stability of incineration facility and the extension of operation period is actualized as a improvement of clogging phenomenon on outer wall of water pipe as the 870~$950^{\circ}C$ maintain of exit temperature in a second combustor by spray of the food wastewater. The 26 items of air pollution matter of nitrogen oxide ($NO_x$), sulfur oxide ($SO_x$) and dioxin etc. are measured. The results show that it is under the value of allowable exhaust standard.
음식물류 폐수를 생활 폐기물 소각로에 직접 분사하여 소각처리 하는 방안에 대하여 검토하였다. 소각설비는 연속 스토카식 실증플랜트를 이용하였다. 그 결과 암모니아성 질소($NH_3$-N)가 다량 함유된 음식물류 폐수를 분사 소각함으로써 질소산화물($NO_x$) 농도저감과 동시에 질소산화물($NO_x$) 저감을 위해 선택적 비촉매 환원장치(selective non-catalytic reduction ; SNCR)에서 사용되는 암모니아($NH_3$)의 사용량을 절감하는 효과를 가져왔다. 또한, 음식물류 폐수를 분사하여 2차 연소실 출구온도를 적정온도인 870~$950^{\circ}C$로 유지하여 소각량을 최대화하는 한편 폐열회수 보일러의 수관외벽 막힘현상 개선을 통한 로의 안정성 확보 및 연속운영기간의 연장을 실현하였다. 질소산화물($NO_x$), 황산화물($SO_x$) 및 다이옥신 등 대기오염물질 26개 항목에 대하여 측정을 실시한 결과 모두 배출허용 기준치 이하의 값을 나타내었다.