• Title/Summary/Keyword: 실리콘틀

Search Result 11, Processing Time 0.02 seconds

The Review for Various Mold Fabrication toward Economical Imprint Lithography (미세패턴 전사기법을 위한 다양한 몰드 제작법 소개)

  • Kim, Joo-Hee;Kim, Youn-Sang
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.2
    • /
    • pp.96-104
    • /
    • 2010
  • We suggest here a cost-effective replica fabrication method for transparent and hard molds for imprinting lithography such as NIL and S-FIL. The process starts with the use of a replica hard mold from a master, using a polymer copy as a carrier. The polymer copy as a carrier was treated by soluble process for forming anti-adhesion layer. Duplicated hard molds can eliminate direct contact between a hard master and a patterned polymer on a substrate and the generated contamination of a master during the imprinting process. The replica hard mold exhibits the glass-like properties introduced here, such as transparency and hardness, make it appropriate for nanoimprint lithography and step-and-flash imprint lithography.

Oxide semiconductor thin film transistors for next generation displays

  • Park, Jin-Seong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.60.2-60.2
    • /
    • 2012
  • 기술의 발전이 비약적으로 성장하면서, 소비자의 요구는 빠르게 변하고 있다. 전자 소자를 응용한 제품 시장은 매해를 거듭할 수록 빠른 속도로 성능을 향상시키고 있다. 이에 따라 디스플레이 시장에서 가장 큰 관심은 작은 화면에서도 높은 해상도를 요구하고, 수광형의 구동방식이 아닌 능동형 구동방식을 갖는 AMOLED (Active Matrix Organic Light Emitted Diode)를 선호하고 있으며, 빠른 응답속도 기반을 갖는 표시소자를 요구하고 있다. 제품 생산자들의 고민은 기존의 비정질 실리콘 기반의 LCD (Liquid crystal display) 구동소자와 공정을 이용하여 소비자의 욕구에 접근하기가 점점 어려워지고 있다. 최근 이러한 문제점을 해결하고자 하는 노력들중에서 산화물 반도체 재료와 이를 이용한 박막 트랜지스터 개발이 큰 관심을 갖고 있다. 최근 InGaZnO 산화물 반도체 재료는 기존의 비정질 실리콘 반도체 재료 보다 높은 전계 이동도(> $10cm^2/V.s$)를 보이고 있으며, 비정질 실리콘 박막 트랜지스터의 구조에서 산화물 반도체 재료의 대체만으로 효과가 보일 수 있어서 큰 연구가 진행되어져 왔다. 하지만, InGaZnO 산화물 박막 트랜지스터에 대한 소자를 AMOLED에 적용할 때, 기존의 LTPS (low temperature poly-slicon)에서는 발견되지 않았던 소자의 전계신뢰성과 이동도 한계가 문제로 제기되었다. 또한, Indium이라는 희소원소의 사용은 향후 공정 단가와 희소 물질에 대한 위협등에 의하여 새로운 산화물 반도체 재료에 대한 요구와 관심이 발생하고 있다. 본 발표에서는 기존의 산화물 반도체 재료에 대한 차세대 디스플레이인 AMOLED와 유연 디스플레이에 대한 응용 가능성을 발표할 예정이다. 또한 산화물 반도체 재료의 신뢰성 문제에 대한 해결방법으로 신규 산화물 반도체 재료에 대한 연구 방향과 indium-free 계열을 이용한 저원가 산화물 반도체 연구에 대하여 소개할 예정이다. 앞으로 산화물 반도체 재료에 대한 연구와 응용은 기존의 실리콘 반도체 틀을 벗어난 새로운 응용분야를 열어줄 수 있을 것으로 기대하고 있으며, 그 기대에 대한 몇가지 예를 통하여 재료와 소자의 응용 가능성을 논의할 예정이다.

  • PDF

Computed tomography investigation of the three-dimensional structure and production method of White Porcelain Water Dropper with Openwork Lotus Scroll Design and Eight Trigram Design in Cobalt-blue Underglaze (CT 조사를 통한 청화백자투각연당 초팔괘문연적의 3차원적 구조와 제작방법에 대한 고찰)

  • Na, Ahyoung;Hwang, Hyunsung
    • Conservation Science in Museum
    • /
    • v.25
    • /
    • pp.1-8
    • /
    • 2021
  • This study investigated White Porcelain Water Dropper with Openwork Lotus Scroll Design and Eight Trigram Design in Cobalt-blue Underglaze (hereinafter, the "water dropper") in the collection of the National Museum of Korea using computed tomography (CT). A replica was produced to examine both the structure and its original production method. The CT scanning identified no joint lines or pores in the clay, which suggests that the body (the lower part of the water dropper) was shaped in a single piece using a mold and was then matched with a mold-formed lid (the upper part of the water dropper). The inner container of the body portion was roughly trimmed with a bamboo knife so that its upper surface could be securely attached to the bottom of the lid and prevent any leakage in the joined surface. It appears that the inner container for storing water was made first in a cylindrical shape that met the unit of quantity used at the time and could be easily formed by molding. It was transformed into a trapezoid shape during the process of combining it with the lid. A cylindrical inner container was reproduced using silicon 3D printing to compare its capacity with that of the original inner container. The comparison revealed that the reproduced container had a capacity of 152.5㎖, whereas the original container holds approximately 168.6㎖, a figure similar to three hop (around 174㎖) in Joseon-period units of quantity. Since the capacity of the cylindrical inner container corresponds to a known measure from the late Joseon dynasty, it is likely that the water dropper was originally produced to contain a cylindrical inner container.

A Study on the Growth Proccess and Strategic Niche Management of New Energy Technology: A Case Study with Government Supporting Photovoltaic R&D Project (전략적 니치관리(SNM)를 활용한 정부 신재생 R&D 성장과정 분석)

  • Kim, Bong-Gyun;Moon, Sun-Woo
    • Journal of Technology Innovation
    • /
    • v.20 no.2
    • /
    • pp.161-187
    • /
    • 2012
  • Recently, environmentally friendly technology are becoming important due to reconsideration about climate change and environmental pollution. In addition, as well as technical skills and social interaction through an analysis of the nonlinear transition management and policy implementation are emerging. This study of the development of photovoltaic industry in Korea 10 years analyze with strategic niche management (SNM) based on the theoretical and multi-layered perspective (MLP) is used as the analytical framework. Choose the gerverment-support project for niche technology, through a process of quantifying and alnalyze the phase transition to Regime with the numerical method and policy vision, learning effects, and network that key elements of SNM, MLP. Through the analysis of the photovoltaic industry technology-commercialization phase was investigated. This conventional overall and step-by-step model for technical management is proposed to replace exiting linear and narrow method and through the case study its validity was confirmed.

  • PDF

Design of Low-cost Automated Ventilator Using AMBU-bag (암부백을 이용한 저가형 자동 인공호흡기 설계 및 제작)

  • Shin, Hee-Bin;Lee, Hyo-Kyeong;Oh, Ga-Young
    • Journal of Appropriate Technology
    • /
    • v.7 no.1
    • /
    • pp.51-58
    • /
    • 2021
  • This study proposes the design and implementation of a low-cost emergency ventilator which can be helpful during the COVID-19 pandemic where the supply of automatic ventilators is not smooth compared with the urgent demand worldwide. Easy implementation and lower price were made possible by using AMBU-bag and off-the-shelf embedded micro-controller board. Moreover, while 3D printing is used by companies and experts around the world to build prototype hardware, materials which are readily available from surrounding environments so that people in countries where it is difficult to access many advanced technologies could manufacture the system. The design features AMBU-bag automation, not use 3D printing, and it can contrl speed. By allowing speed control, ventilation can be performed according to the conditions of the patient being used. A complementary point in the study is that it is difficult to fix the start point of the wiper motor used first. A method for complementing this is a method for replacing the brush DC motor with a position feedback function. Secondly, the AMBU-bag may wear out in the long-term process of compressing the AMBU-bag because the arm and the fixing frame are made of wood. To complement this, the part of fixing frame and arm parts that the AMBU-bag touches need to be wrapped in a material such as silicon to minimize friction.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

금 나노로드 어레이 박막을 이용한 광학형 바이오 센서 개발

  • Yeom, Se-Hyeok;Lee, Dong-Ik;Sin, Han-Jae;Seo, Chang-Taek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.436-436
    • /
    • 2014
  • 본 연구에서는 전 세계적으로 활발히 연구되고 있는 나노바이오센서 분야 중 가장 주목을 받고 있는 LSPR 원리를 이용한 바이오센서를 제작하였다. 금속 나노입자의 국소 표면 플라즈몬 공명현상에 의한 주위환경에 민감하게 반응하는 특성은 고감도 광학형 바이오센서, 화학물질 검출 센서등에 응용된다. 특히 금 나노막대와 같은 1차 나노구조물은 나노막대의 주변 환경 변화에 따라 뚜렷한 플라즈몬 흡수 밴드 변화를 나타냄으로 센서로 적용 했을 때 고감도의 측정이 가능하다. 본 연구에서는 다공성인 알루미늄 양극산화 박막 주형틀을 이용하여 다양한 종횡비를 가지는 금 나노막대를 합성하고, 나노막대 어레이 형태의 박막을 제작하였다. 금 나노막대의 합성은 알루미늄 양극산화막을 사용한 주형제조 방법(template method)을 사용하는 전기화학 증착법을 사용하였다. 우선 부도체인 알루미늄 양극 산화막의 한쪽면을 열증착 장비를 사용하여 금을 증착하여 작업 전극(working electrode)을 형성하였다. 백금 선(platinum wire)을 보조 전극(counter electrode)으로 사용하고 Ag/AgCl 전극을 기준 전극(reference electrode)으로 사용하여 삼전극계(three-electrode system)를 형성하였으며, 금 도금 용액(orotemp 24 gold plating solution, TECHNIC INC.)을 사용하여, 800 mV 전압에서 금 나노 막대를 합성하였다. 금 나노막대의 길이는 테플론 챔버를 통과한 전하량 또는 전기 증착 시간에 비례하여 결정된다. 금 나노막대를 성장시킨 알루미늄 양극산화막을 실리콘 웨이퍼에 은 페이스트를 사용하여 고정시킨 후 수산화나트륨 (NaOH)용액을 사용하여 알루미늄 양극산화막을 녹여내어 수직방향으로 정렬되어 있는 나노 막대 어레이 박막을 제조 하였다. 또한 제작된 금 나노막대 어레이의 광학적 특성을 평가하였다. 본 연구에서와 같이 나노막대를 직경방향으로 측정할 경우, 직경방향의 transverse mode만 측정된다. 금 나노 막대가 알루미늄 양극산화막 안에 포함된 상태로 측정된 금 나노로드 어레이 박막의 광 스펙트럼 분포는 금 나노막대의 가시광영역에서의 흡수 스펙트럼을 측정하였을시 직경 및 길이에 따라 transverse mode의 ${\lambda}$ max (최대 흡광)의 위치가 변화됨을 나타낸다. 실험 결과를 바탕으로 나노막대의 종횡비가 증가함에 따라 흡수 스펙트럼의 transverse mode ${\lambda}$ max가 미약하게 단파장 영역으로 이동하는 것을 확인할 수 있다. 이러한 결과는 원기둥 형태의 금 나노막대의 흡수 스펙트럼에 대한 이론적인 예측과 부합한다. 바이오센서로의 적용 가능성을 확인하기 위하여 자기조립단분자막을 형성하여 항체를 고정하고 CRP에 대한 응답특성을 평가하였다. CRP 항원-항체의 면역반응에 대한 실험 결과 CRP 항원의 농도가 증가함에 따라 넓은 측정범위에서 선형적으로 흡광도가 증가하는 결과를 나타내었으며, CRP 10 fg/ml의 농도까지 검출할 수 있었다. 센서의 선택성을 확인하기 위하여 감지하고자하는 대상물질이 아닌 Tn T 항원을 감지막에 반응시켜 흡광도 변화를 분석하였다. 결과적으로 제작된 센서칩은 선택성을 가지고 측정하고자하는 물질에만 반응함을 확인하였다. 이러한 결과는 다양한 직경을 사용한 부가적인 LSPR현상의 연구에 활용될 수 있을 것이다.

  • PDF

Usefulness of a Functional Tracheobronchial Phantom for Interventional Procedure (중재 시술용 기능성 기관-기관지 팬텀의 유용성)

  • Kim, Tae-Hyung;Lim, Cheong-Hwan;Kim, Jeong-Koo;Kim, Myeong-Soo;Choi, Won-Chan;Lim, Jin-Oh;Lee, Kwang-Jong;Park, In-Ae;Kim, Mi-Ok;Jung, Eun-Mi;Shin, Ryung-Mi;Jung, Seung-Ki;Youn, Sun-Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.27-32
    • /
    • 2003
  • To evaluate usefulness of a functional tracheobronchial phantom for interventional procedure. The functional phantom was made as a actual size with human normal anatomy used silicone and a paper clay mold. A tracheobronchial-shape clay mold was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed. We measured film density and tracheobronchial angle at the human, animal and phantom, respectively. The film density of trachea part were 0.76(${\pm}0.011$) in human, 0.97(${\pm}0.015$) in animal, 0.45(${\pm}0.016$) in phantom. The tracheobronchial bifurcation part measured 0.51(${\pm}0.006$) in human, 0.65(${\pm}0.005$) in animal, 0.65(${\pm}0.008$) in phantom. The right bronchus part measured 0.14(${\pm}0.008$) in human, 0.59(${\pm}0.014$) in animal and 0.04(${\pm}0.007$) in phantom. The left bronchus were 0.54(${\pm}0.004$) in human, 0.54(${\pm}0.008$) in animal and 0.08(${\pm}0.008$) in phantom. At the stent part were 0.54(${\pm}0.004$) in human, 0.59(${\pm}0.011$) in animal and 0.04(${\pm}0.007$) in phantom, respectively. The tracheobronchial angle of the left bronchus site were $42.6({\pm}2.07)^{\circ}$ in human, $43.4({\pm}2.40)^{\circ}$ in animal and $35({\pm}2.00)^{\circ}$ in phantom, respectively. The right bronchus site were $32.8({\pm}2.77)^{\circ}$ in human, $34.6({\pm}1.94)^{\circ}$ in animal and $50.2({\pm}1.30)^{\circ}$ in phantom, respectively. The phantom was useful for in-vitro testing of tracheobronchial interventional procedure, since it was easy to reproduce.

  • PDF

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.