• Title/Summary/Keyword: 신뢰성 시험(reliability test)

Search Result 873, Processing Time 0.032 seconds

Development ofn Sharing Space Access Management System based on Mobile Key and RCU(Room Control Unit) (모바일 키 및 RCU에 기반한 공유공간 출입관리 시스템 개발)

  • Jung, Sang-Joong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.202-208
    • /
    • 2020
  • Recently, the importance of non-face-to-face has been emphasized due to COVID-19, and the use of sharing spaces is also expanding. The use of uncontact check-in technology for access control of sharing spaces reduces waiting time and optimizes workers' efficiency, resulting in operational cost savings. In this paper, we propose a sharing space access management system based on a mobile key and RCU (Room Control Unit), access to the facility using a mobile key, and monitor the facility using an RCU. Proposal system is for shared accommodation, rental field (residence, sale-selling hotel), shared office, etc. when there is a one-time visitor on a specific day and time, the corresponding password is delivered to the mobile platform to expose and key the existing password. It is supported by a field-adaptive system that can reduce discomfort such as delivery. In order to test the operation of the proposed integrated system, tests were conducted according to scenarios to understand the overall status of the user's reservation, check-in, and check-out, and a 100% success rate was derived for each item by setting performance indicators to prove test reliability.

A Study on the Control of Hygroscopicity and Hardness in Polymer Surfaces (고분자 표면의 흡습성 및 경도 제어 연구)

  • Jinil Kim;Young Nam Jung;Doa Kim;Myung Yung Jeong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.86-90
    • /
    • 2023
  • The packaging of electronic devices performs a protective function to ensure that their durability and reliability are not affected by changes in the operating environment caused by external factors. Recent advances in materials have led to ongoing research into bonded packaging of heterogeneous materials such as polymers and inorganic materials in electronic devices. In this packaging process, it is important to have a binding that joins the materials and ensures the operating environment, which includes adhesion to the substrate, corrosion and oxidation resistance through moisture removal, and durability. In this study, the hygroscopicity of the coating layer by modifying the polymer surface based on PVA was evaluated by controlling and measuring the contact angle, and the adhesion was confirmed by applying water-based ink and testing according to ASTM_D3363. For the durability of the polymer surface, the IPL post-treatment process was used to improve the hardness and toughness against applied voltage, and the pencil hardness test and nanoindentation test were conducted. Through this, we analyzed and proposed solutions to ensure the reliability and durability of polymer devices in polymer microfabrication against environmental factors such as moisture, temperature fluctuations and adhesion, and surface abrasion.

Quality Control of Radiation Dosimetry Service (개인피폭선량 측정기관의 품질관리기준 개발)

  • Lee, Jun-Haeng;Lee, Sang-Bock;Chang, Kun-Jo;Lee, Kwang-Yong;Lee, Hyun-Koo;Kim, Hyeog-Ju;Jin, Gye-Hwan
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.253-259
    • /
    • 2009
  • We have developed standards based on international criterions for the quality control of dose tested by the measurement institutions of individual exposure doses through improving the reliability of data on the exposure dose of individuals working in radioactive environment and securing the accuracy and reliability of individual dose measurements. Laws related to radiation dose applied to domestic institutions refer to ANSI N13.11.1993, but currently, in U.S. and some other countries the measurement of radiation doses is based on ANSI N13.11.2001 that reduced test categories and tightened the standards. We made efforts to simplify the standards and to reduce the number of dosimeters required in experiment, and avoided preventing or hindering the use of future technologies not approved under the current law such as glass dosimeter and optical stimulation dosimeter. The Quality Management Manual of Radiation Dosimetry Service, Assessment Manual of Radiation Dosimetry Service Accreditation Program, and the Personnel Dosimetry Performance. Criteria for Testing are documents applicable in supervising laboratories.

  • PDF

Quantitative analysis of hydrogen in thin film by scattering-recoil co-measurement technique (산란-되튐 동시 측정 방법에 의한 박막 중 수소 정량법)

  • Lee, Hwa-Ryun;Eum, Chul Hun;Choi, Han-Woo;Kim, Joonkon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.400-406
    • /
    • 2006
  • Hydrogen analysis by elastic recoil detection has been performed utilizing polyimide film as a reference sample of known hydrogen content assuming the soundness of ion beam current integration. However beam current integration at higher incidence angle is not reliable. Scattering yield per unit fluence by current integration which is normalized per unit path length decreases as the sample tilt angle is getting higher. Moreover because beam current integration at high tilt angle is incomplete, hydrogen evaluation is very risky by direct comparison of sequentially collected recoil spectra between reference and target sample. In this study, primary ion beam dose is determined by backscattering spectrum that is collected simultaneously with recoil spectrum instead of ion beam current integration in order to reduce uncertainty arising in the process of current integration and to enhance the reliability of quantitative analysis. Three test samples are selected $-7.6{\mu}m$ polyimide film, hydrogen implanted silicondioxide and Au deposited carbon wafer- and analyzed by two methods and compared.

Architecture Evaluation Utilizing CBAM and AHP (생체인식 소프트웨어의 품질 평가모듈에 관한 연구)

  • Yang, Hae-Sool;Lee, Man-Ho;Yoon, Young-Mi
    • The KIPS Transactions:PartD
    • /
    • v.13D no.5 s.108
    • /
    • pp.699-708
    • /
    • 2006
  • The latest biometric field have marched fast with security technology of IT. As importance of present biometrics is realized, internal and external biometrics software market is trend that is soaring. Accordingly, high reliability of biometric software and request of high quality software are enlarged. Evaluation items and criteria must be established for biometric software quality assurance. In this paper, we development the evaluation module for biometric software test based on ISO/IEC 12119 that is the standard about software quality requirement and test, and ISO/IEC 9126 that is standard about evaluation of software product, and ISO/IEC 14598-6 that is the standard about construction of the evaluation module. Constituents of biometric software products(product descriptor, user document program and data) is subject to the quality evaluation module that we developed in this paper, we can expect improvement in the quality of software by using with a standard such as ISO/IEC 9126-3 that can be used in software development process.

Development of Mathematics Anxiety Scale for Middle School Students & its Validity (중학생용 수학불안 검사 도구의 개발 및 타당화 연구)

  • Ok, Bo-myoung;Lee, Chang Yeon;Ryoo, Byeong Kook
    • Communications of Mathematical Education
    • /
    • v.35 no.3
    • /
    • pp.233-255
    • /
    • 2021
  • The purpose of this study is to develop math anxiety scale for middle school students for planning and implementing math anxiety treatment programs. In this study, we describe the process of developing and validating math anxiety scale for middle school students and detailing exploratory factor analysis and confirmatory factor analysis to verify construct validity. As a result of the study, we developed the Math Anxiety Scale for Middle School Students (MASS-M) of 30 items with four factors: mathematical curriculum content, mathematical attitude, mathematical test, and environment. As a math anxiety factor for middle school students, MASS-M was developed, which includes mathematical anxiety factors such as mathematical test factor and environmental factor, especially mathematical curriculum content factor describing mathematical treatment, and mathematical attitude factor describing psychological treatment. MASS-M, derived from this study, is a standardized scale for measuring math anxiety in middle school students and is expected to serve as the basis for maintaining consistency in research on math anxiety in middle school students and developing programs to treat math anxiety in middle school students.

Effects of PCB Surface Finishes on Mechanical Reliability of Sn-1.2Ag-0.7Cu-0.4In Pb-free Solder Joint (PCB 표면처리에 따른 Sn-1.2Ag-0.7Cu-0.4In 무연솔더 접합부의 기계적 신뢰성에 관한 연구)

  • Kim, Sung-Hyuk;Kim, Jae-Myeong;Yoo, Sehoon;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.4
    • /
    • pp.57-64
    • /
    • 2012
  • Ball shear test was performed by test variables such as loading speed and annealing time in order to investigate the effect of surface finishes on the bonding strength of Sn-1.2Ag-0.7Cu-0.4In Pb-free solder. The shear strength increased and the ductility decreased with increasing shear speed. With increasing shear speed, the electroless nickel immersion gold (ENIG) finish showed dominant brittle fracture mode, while organic solderability preservative (OSP) finish showed pad open fracture mode. The shear strength and toughness for both surface finishes decreased with increasing annealing time under the high-speed shear test of 500 mm/s. Typically, the thickness of intermetallic compound increased with increasing annealing time, which means that exposure of brittle fracture became much easier. With increasing annealing time, the both ENIG and OSP finishes exhibited the pad open fracture mode. Overall, ENIG finish showed higher shear strength rather than OSP finish due to its superior barrier stability.

Development of Regenerative Inverter for Electric Railway Using Space Vector PWM (SVPWM을 이용한 전기철도용 회생 인버터 개발)

  • 백병산;정문구;김태완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • As a device that returns surplus energy, regenerated from trains to d.c. source, to a.c. system and reuses it, the thyristor Inverter has been widely used. Because the conventional thyristor inverter is a unidirectional phase-controlled device, it Is Impossible to control the power factor of its output. Moreover, harmonics emission is high and it needs to take a additional filter. In this paper, to solve the problems stated above, the inverter, which can control real and reactive power by adopting IGBT modules as switching elements and being controlled by means of space vector PWM, is developed. Considering high economical efficiency and reliability in order to apply to the system for commercial use, the developed inverter is equipped with fully digital control system and low pass filter, and reduces harmonics and has compact size. The detail description about the developed inverter is stated in various respects: design criteria, technical description, power circuits, control techniques, the developed system, test results, etc.

A Study on Certification of Electronic Engine Controls (항공기 엔진제어시스템 인증기술 개발)

  • Lee, Kang-Yi;Han, Sang-Ho;Jin, Young-Kwon;Lee, Sang-Joon;Kim, Kui-Soon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.1
    • /
    • pp.104-109
    • /
    • 2005
  • The aircraft gas turbine engines with the Electronic Engine Controls(EEC) had been developed to save fuel and enhance their performance in the early days, and had employed the health monitoring function in the Full Authority Digital Engine Controls(FADEC) to improve their reliability. This has led to an increasing demand for the certification technology of these controls. The design and certification issues of power supply, aircraft supplied data, failure modes, software verification/validation, and lightning requirements need to be addressed. This paper presents the design considerations and the certification techniques applied to the electronic engine controls. And it is believed that this paper will be basis to establish a requirement in Korean Airworthiness Standard.

Design of Stack Monitoring System with Improved Performance (성능이 향상된 Stack Monitoring System의 설계)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seong-Won;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.299-302
    • /
    • 2016
  • In this paper, we designed the stack monitoring system with improved performance. To block the incoming pulse noise to the amplifier, shield and the power supply impedance are reduced and the power circuit is isolated. The control unit is developed with variable high voltage, adaptive gain, offset and threshold in order to match the scintillation detector characteristic to the apparatus. 300-1500V variable high voltage power circuit is configured applicable to various scintillation detector. Stack monitoring system with improved performance guarantee the efficiency and the reliability by considering the characteristic of various scintillation detector. Developed stack monitoring system is evaluated with certified testing equipment and shows excellent performance with respect to the uncertainty of the sensor test results.