• Title/Summary/Keyword: 신뢰도측정

Search Result 1,889, Processing Time 0.031 seconds

Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool (하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토)

  • Yim, Ji-Young;Yim, Hyun-Seung;Park, Dae-Sung;Lee, Na-Kyung;Lee, Na-Kyung
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • The purpose of this study was to assess the intra-rater, inter-rater and test-retest reliability and validity of frontal plane lower extremity alignment estimated from a rasterstereographic method using ABW-Mapper. Eighteen subjects participated in this study. The S angle (stereographic angle-frontal plane lower extremity alignment estimated from a rasterstereographic method) in standing was measured throughout the two sessions with one week interval by two different readers. In the first session, a reader measured S angle twice per subject with a short break in-between. The Q-angle (quadriceps angle) was measured using a standard goniometer from a photography taken through digital camera with the participant standing in the same position as in the S angle measurement. The HKA(hip-knee-ankle) angle was measured from a computer based digital radiograph with the computerized measurement software. Reliability was tested using intraclass correlation coefficients(ICC). Validity was tested using a Pearson's correlation coefficient. Excellent intra-rater(ICC=0.956~0.974), inter-rater(ICC=0.962), test-retest reliability (ICC=0.945) were demonstrated. There were strong negative correlations between S angle and Q-angle (r=-0.739), and between S angle and HKA angle (r=-0.702). Therefore, the S angle measured using a rasterstereographic mapper may be used to as a preliminary or supplementary tool to evaluate and study LE alignment in the frontal plane in relation to HKA angle or Q-angle.

Validity and Reliability of a Korean Version of the Flow State Scale for Occupational Task (한글판 작업과제 몰입상태척도(Korean version of Flow State Scale for Occupational Task: K-FSSOT)의 타당도 및 신뢰도연구)

  • Lee, Jeong-Hoon;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.4
    • /
    • pp.53-63
    • /
    • 2021
  • Objective : This study aimed to develop a Korean version of the Flow State Scale for Occupational Task (K-FSSOT), to measure the level of a flow experience of a subject in occupational therapy activities. Methods : To develop a measure of K-FSSOT, validity and reliability were verified through a systematic development process. The validity was verified by calculating the content validity index (CVI) through the content validity of 10 occupational therapists and a question-and-answer survey of 20 patients. Reliability was verified by investigating the internal consistency and examination-re-test reliability of 33 patients. Results : The item-CVI for each question in the content feasibility study was .90 to 1.00, and the scale-CVI, which is the average of the whole item, was found to be appropriate at .97. The verification of reliability indicated that the intrinsic value of the entire question was high at .855, and the test-retest reliability value was high at .894 (p<.01), showing a high correlation, and very high reliability. Conclusion : K-FSSOT could be used as a useful tool to measure the level of a flow experience of the target in performing occupational therapy activities for occupational therapists concerned about the participation and flow experience of the target.

The inter-rater absolute reliability and validity of the Figure-of-8 Walk test in patients with chronic stroke (만성 뇌졸중 환자 8자 모양 경로 보행 검사의 측정자간·절대적 신뢰도와 타당도)

  • Park, Chang-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.467-474
    • /
    • 2017
  • To investigate the intra-rater absolute reliabilities and validity of the Figure of-Eight Walk test (F8WT) in patients with chronic stroke. A total of 36 subjects with chronic stroke participated in this study. The inter-rater reliability of F8WT was calculated using intra-class correlation coefficients($ICC_{2,1}$). Moreover, we used the standard error measurement (SEM) and the small real difference (SRD) to examine the absolute reliability indices. The validity was demonstrated by a spearman correlation of F8WT with Postural Assessment Scale for Storke(PASS) and Trunk Impairment Scale(TIS). The inter-rater reliability of F8WT was excellent; ICC2,1=0.95(0.91~0.97), acceptable SEM=1.02, and SRD=2.82. F8WT were also found to be significantly associated with PASS(r=-0.82) and TIS(r=-0.85). Therefore, F8WT is a reliable measurement tool and is correlated well with stroke-impairments, such as postural and trunk control. F8WT will be a useful tool in evaluating the walking performance of subjects with chronic stroke.

Rejection Performance Analysis in Vocabulary Independent Speech Recognition Based on Normalized Confidence Measure (정규화신뢰도 기반 가변어휘 고립단어 인식기의 거절기능 성능 분석)

  • Choi, Seung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.96-100
    • /
    • 2006
  • Kim et al. Proposed Normalized Confidence Measure (NCM) [1-2] and it was successfully used for rejecting mis-recognized words in isolated word recognition. However their experiments were performed on the fixed word speech recognition. In this Paper we apply NCM to the domain of vocabulary independent speech recognition (VISP) and shows the rejection Performance of NCM in VISP. Specialty we Propose vector quantization (VQ) based method for overcoming the problem of unseen triphones. It is because NCM uses the statistics of triphone confidence in the case of triphone-based normalization. According to speech recognition experiments Phone-based normalization method shows better results than RLJC[3] and also triphone-based normalization approach. This results are different with those of Kim et al [1-2]. Concludingly the Phone-based normalization shows robust Performance in VISP domain.

A Study Software Reliability Model Using Error-Class (오류 분류를 이용한 소프트웨어 신뢰도 모델)

  • Jo, Yeong-Sik;Lee, Yong-Geun;Choe, Hyeong-Jin;Yang, Hae-Sul
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.2
    • /
    • pp.231-241
    • /
    • 1996
  • The reliability in software has expand in quality and quantity, also its importance and role are increased. But, a study of software reliability is lack of development. this paper software reliability growth models(SRGM) described by NonHome-geneous Poisson(NHPP)processes. Using actual software error data observed by software testing the SRGM's are composition of error-class, and error-class by three class. this paper made the reliability-model of software using three error- class. The purpose of this study to increase software productivity and to improve software quality. So to achive these goals we focused a study of software reliability model using the error-class.

  • PDF

The Confidence Estimation of MOI Measurement Equipment using Uncertainty Analysis (불확도 분석을 이용한 관성모멘트 측정장비의 신뢰도평가)

  • Kim, KwangRo;Kang, HuiWon;Shul, ChangWon
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.3
    • /
    • pp.53-57
    • /
    • 2018
  • The Monte Carlo simulation (MCS) method and the Guide to the Expression of Uncertainty in Measurement (GUM) are the most widely used approaches for uncertainty estimation. In this paper, MCS and GUM were used to estimate the confidence of MOI measurement equipment developed in-house. According to the results, the GUM estimated uncertainty was slightly underestimated compared to the MCS method. This difference is due to the approximation used by GUM. MOI uncertainties estimated by both methods were less than 1% of the estimate, which shows the high measurement reliability of the developed MOI measurement system.

Converged Study on the Validity and Reliability of the Communication Behavioral Scale of nurses caring for people with dementia (치매대상자를 돌보는 간호사의 의사소통행위 측정도구의 타당도 및 신뢰도 융합 연구)

  • Gang, Moon-Hee;Lee, Ji-Hye
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.327-333
    • /
    • 2020
  • The aims of this study was to verify the validity using group comparison method and test/retest reliability of the Communication Behavior Scale for Nurses Caring for People with Dementia(CBS-D). The subjects were nurses who have worked at elderly care facilities in D, U and Y cities(n = 67), and nurses who have worked at general hospitals in D and U cities. The scores of the communication behaviors of nurses working in elderly care facilities were significantly higher than those of nurses working in general hospitals(t=2.49, p=.014). The Intraclass Correlation Coefficients for the test-retest reliability test was .813. Therefore, it was confirmed that CBS-D is an appropriate evaluation tool for evaluating the level of the nurse's communication behavior through various logical analyzes, and it is expected that it can be used in various ways for nursing care for people with dementia.

Feasibility and Reliability Analysis of Convergent Job Measurement Tool for Elementary School Health Teachers (초등학교 보건교사를 위한 융복합적 직무측정도구의 타당도와 신뢰도 분석)

  • Lee, Mi Joon
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.9
    • /
    • pp.117-125
    • /
    • 2019
  • This study aims to evaluate of validity and reliability of the job performance tool already developed for the elementary school health teachers. 305 health teachers responded to the questionnaire composed of 50 items. The validity and reliability of the tool were verified by confirmatory factor analysis. That were composed of 8 sub-categories and had 4 factors. The importance, frequency, and difficulty of the four factors were classified according to the questionnaire criteria, but the importance of health promotion is classified as one new item factor. The statistical significance of the fit of the model was 3.664 (df = 246, p<0.001), RMSEA=0.09, NFI=0.85 and CFI=0.88. The internal consistency of the subscales was Cronbach's ${\alpha}$ of 0.88 to 0.96. The internal consistency of the subscales, Cronbach's ${\alpha}$ was 0.88~0.96. This study shows that the analysis tool for primary school health teacher is valid and reliable as a measurement tool.

디젤발전기 엔진 상태신호 측정 및 분석 사례

  • Choe, Gwang-Hui;Lee, Sang-Guk;Lee, Byeong-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.745-745
    • /
    • 2012
  • 원자력발전소에서 비상디젤발전기는 노심의 안전성을 지키는 매우 중요한 역할을 담당하고 있다. 이를 위해 디젤발전기는 신뢰성능 높게 유지하도록 규제요건이 마련되어 있다. 디젤발전기의 엔진 상태를 주기적으로 감시하고 평가하기 위해서는 엔진 상태 신호 분석 기술이 필요하다. 엔진 상태 신호 분석에는 연소분석과 진동 및 초음파 측정 및 분석기술이 중요한 비중을 차지한다. 연소 분석은 디젤 엔진의 개별 실린더에 대한 연소 성능에 대한 정보를 제공한다. 진동 및 초음파 분석은 이벤트 타이밍과 기계적 상태에 대한 정보를 알려준다. 이들 신호는 정상적인 부하로 운전하는 디젤엔진의 가동에 영향을 미치지 않고 수집할 수 있다. 엔진 상태 신호 분석을 이용하는 주요 동기는 전통적으로 장비 제작자의 권고에 따라 수행되는 분해-검사 유지 보수 프로그램을 일부 대체하고 예측정비를 통해 신뢰도를 유지하기 위함이다. 상태 진단정비는 엔진 상태 신호분석을 주로 이용하여 엔진의 신뢰도와 이용률을 증가시킬 수 있다. 본 논문에서는 국내외서 경험한 엔진상태신호 측정 및 분석 사례를 기술하였다.

  • PDF

Development and Validation of Teaching Mathematics Anxiety Scale for Elementary Teachers (초등학교 교사의 수학교수불안(數學敎授不安) 측정 도구 개발 연구)

  • Kim, Rina
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.19 no.4
    • /
    • pp.649-666
    • /
    • 2015
  • The purpose of this study was to develop and validate a teaching mathematics anxiety scale for elementary teachers in South Korea. The sample consisted of 150 elementary teachers in 22 elementary schools in Seoul. A total of 21 items were developed and examined for the internal consistence. The results showed that the proposed scale was appropriate to represent the teaching mathematics anxiety of elementary teachers.