• Title/Summary/Keyword: 시편 진동

Search Result 124, Processing Time 0.022 seconds

Modal Identification and Seismic Performance Evaluation of 154kV Transformer Porcelain Bushing by Vibration Test (진동시험에 의한 154kV 변압기 부싱의 동특성 분석 및 내진성능 평가)

  • Joe, Yang-Hee;Cho, Sung-Gook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.107-115
    • /
    • 2006
  • The power supply system is one of the most important infrafacilities which should maintain their inherent function during and after earthquakes. This study was performed to analyze dynamic characteristics and seismic performance of Korean typical 154kV transformer porcelain bushing. For the purpose of this study, actual 154kV porcelain bushings were selected and tested on the shaking table. The vibration tests consist of modal identification tests, seismic performance tests, and fragility tests. The sine sweep waves, artificial earthquake waves, and continuous resonant sine waves were used as shaking table motions. This paper describes the test specimens, shaking facilities, and test methods. Natural frequencies and damping ratios of the bushing have been evaluated from the experimental data. The failure mode and the performance level of the Korean transformer bushing have been first identified in this study.

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

  • PDF

A Study on the Transmission Loss Test with an Impedance Tube for KS (투과손실 관내법 KS 규격화 연구)

  • Jung Sung Soo;Jho Moon Jae;Kim Yong Tae
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.233-234
    • /
    • 2004
  • 각종 재료의 음향투과손실을 간단히 비교 시험할 수 있는 관내법이 향후 국제규격으로 제정될 것에 대비하여 우선 KS 규격 제정을 목적으로 제반 특성평가를 수행하였다. 이를 위해 임피던스관을 제작하고, 관 벽을 따라 시편을 지나 마이크로폰 위치까지 전달되는 진동량, 무반사처리부의 흡음률 등 기본적인 특성을 살펴보았다. 최종적인 검증을 위해 몇 가지 시편에 대해 투과손실을 측정하고 이론적 해석에 의한 예측 값과 비교하였다.

  • PDF

Dynamic Property Evaluation of Four-Harness Satin Woven Glass/epoxy Composites for a Composite Bogie Frame (복합소재 대차프레임용 4매 주자직 유리섬유/에폭시 복합소재의 진동특성평가)

  • Kim, Il Kyeom;Kim, Jung Seok;Seo, Sung Il;Lee, Woo Geun
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • In this study, the natural frequency and damping ratio of a four-harness satin woven glass/epoxy composite material are evaluated by means of modal tests and a finite element analysis. To achieve this goal, glass/epoxy beam specimens with different lengths and thicknesses were manufactured via autoclave curing. In the test, the maximum damping ratio was found to occur at the lowest test frequency. As the test frequency increased, the damping ratio decreased exponentially to a critical value. After that value, the damping ratio increased gradually to the maximum test frequency.

Experimental Assessment of PBGA Packaging Reliability under Strong Random Vibrations (강력한 임의진동 하에서 PBGA 패키지의 실험적 신뢰성 검증)

  • Kim, Yeong K.;Hwang, Dosoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.3
    • /
    • pp.59-62
    • /
    • 2013
  • Experimental analyses on the solder joint reliability of plastic ball grid array under harsh random vibration were presented. The chips were assembled on the daisy chained circuit boards for the test samples preparation, half of which were processed for underfill to investigate the underfill effects on the solder failures. Acceptance and qualification levels were applied for the solder failure tests, and the overall controlled RMS of the power spectrum densities of the steps were 22.7 Grms and 32.1 Grms, respectively. It was found that the samples survived without any solder failure during the tests, demonstrating the robustness of the packaging structure for potential avionics and space applications.

Quantitative Structure Determination of Ni(111)(2×2)-O/CO: temperature Dependent Study (광전자회절을 이용한 Ni(111)(2×2)-O/CO의 표면 흡착 구조: 시편준비의 온도 의존성)

  • Kang J.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.92-97
    • /
    • 2006
  • A study of the adsorption site of CO in the Ni(111)$(2\times2)$-O/CO coadsorbed phase over different sample preparation temperatures revealed that the atop site is favoured. The Ni-C spacing is given by $1.77\pm0.01\;{\AA}$. A study of the adsorption site of Co in the Ni(111)$(2\times2)$-O/CO coadsorbed phase over different sample preparation temperatures revealed that the atop site is favoured. The Ni-C spacing is given by $1.77\pm0.01\;{\AA}$. The data from the sample prepared at 265 K showed atop sites, which is well consistent with vibrational spectroscopy, whilst the data from the low temperature preparation appears the mixture of atop and hop $(35\%)$. The occupation of hop hollow sites is probably due to an incorrect pre-coverage of atomic oxygen (different from 0.25ml). Similar observation of site mixture also found in recent high resolution XPS measurements using C 1s and O 1s chemical shifts.

Improvement Effects on Lock-in Thermography by Iterative Adaption in Optical Excitation (광학가진의 반복 정합에 의한 위상잠금 열화상 개선 효과)

  • Kim, Won Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.376-381
    • /
    • 2013
  • 위상잠금 열화상에서는 일반적으로 변조된 주파수의 광램프를 쓰고 있다. 하지만 램프의 광도 분포는 입력신호가 평단(flat)특성임에 불구하고 심지어 불균일하여 검사 시편내에 측면 열유동을 만들어낸다. 이러한 열유동은 원치 않는 효과로서 측면의 분해능을 감소시키는 등과 같이 관심 결함구조의 영상에 부정적인 영향을 미친다. 본 고에서 검토되는 방식은 열원으로서 LCD 프로젝터와 같은 것을 이용하여 각 가진픽셀에 개별적으로 진동진폭, 광도 오프셋, 위상지연 등을 할당하는 방법에 대한 접근기술이다. 이러한 반복적인 자체학습 과정에 의한 조명 패턴을 통하여 측면 열유동이 제거되고 분해능이 향상되도록 제공하는 것이다.

지능 외팔보의 동탄성 실험

  • 박용군;최승복;정재천;김기선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.206-210
    • /
    • 1992
  • 본 연구는 ER(electro-rheological) 유체를 특징으로하는 지능외팔보의 고유주파수, 강성, 댐핑 등이 전장(electric field)에 따라 변화함을 고찰하였고 향후 능동제어계(active control system)에서 ER유체가 엑튜에이터로써 사용가능함을 보여주었다. ER 유체의 종류, 농도, 체적비, 시편의 전하특성에 따른 지능보의 동탄성 특성을 자유진동과 강제진동하에서 실험하여 비교분석하였다.

Development of FBG sensor System for Measuring the High Frequent Vibration of Structures and the Natural Frequency of Composites (고주파 진동 측정을 위한 FBG 센서 시스템 개발 및 복합재 시편의 고유진동수 측정)

  • Kim, Dae-Hyun;Koo, Bon-Yong;Kim, Chun-Gon;Hong, Chang-Sun;Lee, In
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.159-162
    • /
    • 2002
  • We introduce a simple optically passive detection scheme for Bragg grating sensors. This detection scheme is based on two cavity lengths in Fabry-Perot read-out interferometers to produce two quadrature phase shifted signals from the Bragg grating sensor. The passive detection technique is demonstrated by the use of Bragg grating sensors in measuring the dynamic vibrations of the composites.

  • PDF

An acoustic evaluation of bottom-ash light-weigh concrete panel using small-scale Panel (축소시편을 이용한 Bottom ash 경량콘크리트패널의 차음성능평가)

  • Chung, J.Y.;Im, J.B.;Jeong, G.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.951-955
    • /
    • 2007
  • Recently, drywall's demand is increasing by interest about spread of remodeling house and separated wall structure. This research evaluated panel's SRI and found out panel properties using material of small size. Conclusion of this research is as following. First, we confirmed the effectiveness of small-scale material. Measuring results appeared equally about 400 ${\sim}$ 500 Hz that is fc frequency. Second,, it is no big difference in SRI that use CRC or magnesium board that is used for protection of panel surface. Third, it is compared SRI by used junction to make wall that become disjointing assembly. By the result, sealed wall secures resemblant SRI performance almost with normal wall. Therefore, using joint materials and sealing junction became wall that is detached with high SRI.

  • PDF