• Title/Summary/Keyword: 수화열온도

Search Result 218, Processing Time 0.02 seconds

A Study for Control of Thermal Cracking by Heat of Hydration in Subway Concrete Box Structure (지하철 콘크리트 BOX 구조물의 수화열에 의한 온도균열 제어 방안 연구)

  • Song, Suk-Jun;Yoo, Sang-Geon;Park, Ji-Woong;Kim, Eun-Kyum
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.1024-1029
    • /
    • 2009
  • According to increase of massive concrete structures, Thermal crack done by heat of hydration have been increased in a process of the execution. In case of a subway concrete box structure, thickness of structures are almost over 1 meter, and penetrating crack by external restraint takes a bad effect on the durability with a water leakage and deterioration in especially concrete wall. A try of shortening a constructing period often occurs as subway is generally constructed according to a road to decrease a traffic jam. The research proposes executing method by skipping one block as a plan of shortening a constructing period and investigate an influence on thermal cracking control. Additionally, sensitivity analysis is accomplished by changing a height of a concrete wall, and concrete placing and air temperature met with a field condition.

Effect of Hardening Accelerators on the Adiabatic Temperature property Properties of Precast Concrete and FEM analysis for Evaluating the Crack Performance (경화촉진제를 사용한 프리캐스트 콘크리트의 단열온도특성 및 FEM해석에 의한 균열성능 평가에 관한 연구)

  • Min, Tae-Beom;Cho, In-Sung;Mun, Young-Bum;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, initial crack index was evaluated by FEM analysis to find the crack propagation from hydration heat in precast concrete. As results, as the usage of hardening accelerator increased, initial compressive strength increased and setting time was shortened. Additionally, as amounts of hardening accelerators increased, the central temperature of concrete increased and the time to reach the highest temperature was shortened. It was demonstrated that the hardening accelerators accelerated the hydration reaction of cement, and caused the increase of hydration heat within the short period of time. Furthermore, the crack index for evaluating the heat level was performed by FEM. As results, there was no problem about the cracks, despite of the growth of initial high hydration heat. This is because of the increased tensile strength that is large enough to sustain the thermally induced-stress.

Hydration Heat and Shrinkage of Concrete Using Hwangtoh Binder (황토결합재를 이용한 콘크리트의 수화열과 수축특성)

  • Kang, Sung-Soo;Lee, Seong-Lo;Hwang, Hey-Zoo;Cho, Min-Chol
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.5
    • /
    • pp.549-555
    • /
    • 2008
  • In this paper, the applicability of Hwangtoh, as an alternative of cement paste, is investigated for the solution of internal heat and shrinkage caused by the hydration of cement paste. Several small-sized specimens of Hwangtoh and ordinary portland concrete (OPC) were compared as to compressive strength, heat of hydration, and shrinkage strain. Moreover, the applicability to the construction structures was reviewed through the test of large-size specimens. The 28-day compressive strength of Hwangtoh concrete (HBC), ranged 18 to 33 MPa, can reach that of OPC. Not only the maximun internal temperature of HBC was read about 1/4 of OPC as it is cured, but also its shrinkage decreased more than the OPC did. Therefore, Hwangtoh binder is more favorable than cement binder in terms of its hydration heat and shrinkage under the construction of concrete.

A Study of the Thermal Analysis for the Crack Control of Underground Pier Footing (지하 교각 기초의 온도균열 제어를 위한 수화열 해석 연구)

  • Park, Weon-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.91-101
    • /
    • 2006
  • Lately, massive concrete structures are increasingly built. In such massive structures, the heat of hydration of mass concrete causes thermal cracks. To avoid thermal crack, methods widely acceptable for practical use are pre-cooling, pipe cooling and control of placing height. Thermal stress analysis is performed to find the way of controlling the thermal crack of pier footing mat in this paper. The footing mat model for the analysis is $12m{\times}14m$area and 3m height. The analysis results are compared with method of control of lift height and method of pipe cooling. The analysis results show that thermal crack can be removed by method of placing control and pipe cooling at footing mat placed on the ground.

Effect of Phase Change Material on Hydration Heat of Mortar with Fly Ash and Blast Furnace Slag (상전이물질이 플라이애시 및 고로슬래그를 혼입한 모르타르의 수화발열에 미치는 영향)

  • Nam, Yi-Hyun;Jang, Seok-Joon;Kim, Sun-Woong;Park, Wan-Shin;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Phase change material(PCM) has the capacity to absorb or release energy in heat when the phase changes. This study conducted to investigate the effect of strontium-based PCM on the hydration heat and mechanical properties of mortar with fly ash and blast furnace slag. The amounts of PCM were 1%, 2%, 3%, 4%, and 5% by the cementitious materials weight. The tests about mortar flow, semi-adiabatic temperature rise, compressive and flexural strength tests were carried out for twelve types of mortar mixtures. The test results indicated that the use of PCM was effective to reduce hydration heat and retard hydration of mortar with industrial by-products. In particular, the heat generation rate of mortars with fly ash was lower than that of mortars with blast furnace slag. The compressive strength of mortar with fly ash and blast furnace slag were decreased with increasing PCM ratio.

Analysis of the Effect of Solar Radiation on Internal Temperature Distribution in Concrete Mat Foundation (태양 복사열이 콘크리트 매트기초의 내부 온도분포에 미치는 영향에 관한 해석적 연구)

  • Song, Chung Hyun;Lee, Chang Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.1
    • /
    • pp.63-72
    • /
    • 2017
  • This research investigated the effect of solar radiation on the temperature distribution in concrete mat foundation. Zhang and Huang Model was utilized to estimate solar radiation heat at a given date and time. A one-dimensional finite element formula was derived with the fundamental laws of heat transfer and Galerkin method. Based on the formula, a one dimensional finite element analysis code was developed using MATLAB. Hydration heat analysis of mat foundation were conducted using the developed code. It was found that the solar radiation reduced the maximum temperature difference in mat foundation, and this temperature difference reduction was more prominent in case of summer season cast, a higher initial concrete temperature, and a thicker mat foundation depth. The research recommended that the solar radiation should be considered in hydration heat analysis of concrete mat foundation so as not to overestimate the maximum temperature difference in mat foundation.

A Study on Expedite Heat Transfer in Packed Bed of Hydration Calcined Dolomite for Chemical Heat Pump (소성 Dolomite 수화물 화학열펌프의 고체반응층 전열촉진 연구)

  • Kim, Jong-Shik;Lee, Han-Gyu;Park, Young-Hae
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.434-439
    • /
    • 2005
  • The reaction of hydration proceeded at the same time the vapor was introduced into the reactor that was filled with calcined dolomite. It has shown that the temperature has begun to fall from the bottom of reactor after increase of temperature by the heat of hydration reaction. The reaction initiated at the pipe wall and the heat was transfer to the center of block between the fins. The results show that the use of copper fin in the reactor reducted the hydration reaction time by half when compared to the case without using the fins.

Hydration heat and autogenous shrinkage properties of silica-fume included mass concrete (실리카퓸을 사용한 매스콘크리트의 수화열과 자기수축 특성)

  • Kim, Chin-Yong;Kim, Jin-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.489-492
    • /
    • 2008
  • Adiabatic temperature rise and autogenous shrinkage experiments were performed for three silica-fume included mass concrete mixtures and a reference mixture without silica-fume, in order to investigate the influence of silica-fume on the hydration heat and autogenous shrinkage properties of mass concrete, and to examine applicability of silica-fume to mass concrete. It was revealed from the experiment that, for mass concrete, the rate of hydration was hardly increased while the maximum adiabatic temperature rise decreased about 5$^{\circ}$C by the addition of silica-fume, and the amount of autogenous shrinkage was almost the same regardless of silica-fume replacement. These facts imply that silica-fume can enhance the resistance of mass concrete to temperature cracking as well as the durability.

  • PDF