• Title/Summary/Keyword: 수의 영상진단

Search Result 1,906, Processing Time 0.031 seconds

Radiation Exposure Dose Reduction on Upper Gastrointestinal Series (위장조영검사에서 피폭선량 저감)

  • Lim, Byung-Hak;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2017
  • Upper gastrointestinal series is non-invasive examination, and it is useful for patients or elderly patients who have difficulty in endoscopic examination because of absence of any side effects other than temporary constipation or abdominal pain. The entire image of the gastrointestinal tract can be seen and have been widely used in the diagnosis of upper gastrointestinal diseases. However, there is a possibility that radiation dose increases due to improper movement and breath control, when examination is carried out by lack of understanding the overall inspection process for the upper gastrointestinal series. In upper gastrointestinal series to increase understanding of examination, to induce appropriate cooperation during examination, to reduce the number of retakes and shorten examination time, and to reduce dose of the subject, the procedure and precautions of the gastrointestinal test were made as a movie. We investigated the effectiveness of pre-education using the movie to reduce the inspection time, the number of re-shoots, and the reduction of exposure dose by watching the movie during the waiting time before examination. 120 patients that were selected each 20 patients aged from 30s to 80s were evaluated were evaluated for exposure dose, examination time, and the number of retakes before and after the movie training. The radiation dose, the examination time, and the number of retakes were respectively $3171.83{\mu}Gy{\cdot}m^2$ and $2931.73{\mu}Gy{\cdot}m^2$, 8.05 min, and 6.75 min, and 1.68 times and 1.22 times before and after movie training. It can be concluded that the movie training on the gastrointestinal examination influences the reduction of the examination time, the number of retakes and the reduction of the radiation dose.

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Urinary tract infections in infants under six months of age (6개월 미만 영아의 요로 감염)

  • Kang, Min Joo;Shin, Hye Kyung;Yim, Hyung Eun;Je, Bo-Kyung;Eun, So Hee;Choi, Byung Min;Park, Jong-Tae;Eun, Baik Lin;Yoo, Kee Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.3
    • /
    • pp.278-286
    • /
    • 2006
  • Purpose : Although suprapubic bladder aspiration(SBA) is the most reliable technique for identifying bacteriuria in young infant, no report has been published about the clinical manifestations of urinary tract infection(UTI) diagnosed by aspirated urine in Korea. This study was performed to examine clinical manifestations and related factors of UTI confirmed by a positive urine culture obtained by SBA in young infants. Methods : We reviewed medical records of 159 infants younger than six months of age, who had been admitted for UTI to Korea University Ansan Hospital from January 2002 to June 2005. Results : The male:female ratio was 5.1 : 1. The most common pathogen in urine culture was Escherichia coli(92.5 percent). Most of the gram-negative pathogens had high sensitivity to amikacin, or third generation cephalosporins and had low sensitivity to ampicillin, trimethoprim-sulfamethoxazole, or gentamicin. Hydronephrosis and vesicoureteral reflux(VUR) were present in 32.7 percent and 27.7 percent respectively. Renal cortical defects observed on DMSA scans were detected in 37.1 percent. Prolonged fever duration and hospital day, high erythrocyte sedimentation rate(ESR) and C-reactive protein(CRP) levels, hydronephrosis and VUR were related to the renal cortical defects(P<0.05). Rates of UTI-associated bacteremia and aseptic meningitis were 8.3 percent and 6.6 percent. Conclusion : Early differential diagnosis is very important in infants younger than 6 months of age with UTI because the clinical findings are non-specific and UTI-associated bacteremia and aseptic meningitis are concomitantly found. Because prolonged fever and higher ESR and CRP levels are risk factors of the renal cortical defects, radiologic evaluations and nephrologic follow-up were needed in identifying the predisposing congenital abnormalities and chronic renal scarring.

A Clinical Study for Gall Bladder Stones in Children (소아 담석증에 대한 임상적 연구)

  • Eun, Ho Seon;Baek, Seoung Yon;Chung, Ki Sup
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.8 no.2
    • /
    • pp.194-201
    • /
    • 2005
  • Purpose: Gall bladder (GB) stones in children are rarely observed, and so reports of them have been quite limited in Korea. Therefore, we tried to assess the epidemiology and clinical features of children with GB stone diagnosed at Severance Hospital. Methods: A clinical study was performed on 18 patients below 15 years of age diagnosed with GB stone by abdominal ultrasonography or CT scan at Severance hospital from January 1999 to May 2005. Results: Concerning patients' profile, their sex ratio of male to female in total 18 cases was 2 : 1 with the mean age of $6{\pm}4.3years$. 15 patients (83.3%) were asymptomatic. Inducing factors were found in 14 children (77.8%) including ceftriaxone therapy in 6 cases (33.3%), infection in 4 cases (22.2%), spherocytosis in 3 cases (16.7%), Down syndrome and abdominal operation in 1 case (5.6%) respectively. Single stone was found in 13 cases (76.5%) and multiple in 4 cases (23.5%). 15 cases (88.2%) had the stones less than 5 mm in size, and 2 cases (11.8%) between 5 and 10 mm. 17 patients received conservative treatment, and one patient had cholecystectomy due to Meckel diverticulum. Conclusion: In this report, Pediatric GB stones are predominant in male children, without typical symptoms, having inducing factors, single and small. Recently the diagnosis of them has been increased because of the development of imaging study. But the reports for them were still rare in Korea. Therefore the study for them is more necessary to find it's clinical characteristics.

  • PDF

Incidental Benign Parotid Lesions on FDG-PET: Prevalence and Clinico-pathologic Findings (FDG-PET 검사시 우연히 발견한 양성 이하선 병변: 유병율과 임상 및 병리 소견)

  • Lim, Il-Han;Lee, Won-Woo;Chung, Jin-Haeng;Park, So-Yeon;Kim, Sang-Hee;Kim, Yu-Kyeong;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.5
    • /
    • pp.359-363
    • /
    • 2007
  • Purpose: Incidental parotid lesions on F-18 FDG-PET can mimic distant metastasis of underlying malignancy. The prevalence and the clinico-pathologic findings of PET positive parotid lesions have not been known. We investigated how often incidental parotid lesions are found on clinical FDG-PET studies and what the clinico-pathologic characteristics of those parotid lesions are in the present study. Materials and Methods: We retrospectively reviewed 3,344 cases of FDG-PET which had been obtained in our hospital from May 2003 to Dec 2006. The indications of FDG-PET were: evaluation of known/suspected cancer (n= 3,212) or screening of cancer in healthy subjects (n=132). Incidental parotid lesion on FDG-PET was defined as an un-expected FDG uptake in one of parotid glands which was not primary target lesion of current FDG-PET. FDG uptake was represented by maximum standardized uptake value (maxSUV). Final diagnosis was made by pathologic analysis or clinical follow-up assessment. Results: Fifteen (0.45% = 15/3,344) incidental parotid lesions were found and they were all benign lesions. The maxSUV ranged from 1.7 to 8.6 (mean${\pm}$s.d. = $3.7{\pm}1.9$). Final diagnoses of the incidental parotid lesions were; Warthin's tumor (n=2), pleomorphic adenoma (n=1), other un-specified benign lesion (n=1), and benign lesions under bases of imaging studies (n=3) and of clinical follow-up (n=8). Conclusion: All of incidentally found parotid lesions in clinical FDG-PET studies were confirmed as benign lesions with prevalence of 0.45%. Close follow up using PET or CT might be a reasonable approach for determining the nature of incidentally found parotid lesions.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

The Evaluation of TrueX Reconstruction Method in Low Dose (저선량에서의 TrueX 재구성 방법에 의한 유용성 평가)

  • Oh, Se-Moon;Kim, Kye-Hwan;Kim, Seung-Jeong;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • Purpose: Recently in diagnostics area PET/CT is using a variety of areas including oncology, as well as in cardiology, neurology, etc. While increasing in the importance of PET/CT, there are various researches in the image quality related to reconstruction method. We compared and tested Iterative 2D Reconstruction Method with True X Reconstruction method by Siemens through phantom experiment, so we can see increasing of clinical usefulness of PET/CT. Materials and Methods: We measured contrast ratio and FWHM due to evaluating images on dose and experiment using Biograph 40 True Point PET/CT (Siemens, Germany). Getting a result of contrast ratio and FWHM, we used NEMA IEC PET body phantom (Data Spectrum Corp.) and capillary tube. We used the current TrueX and the previous Iterative 2D algorithm for all images which have 10 minutes long. Also, a clinical suitability of parameter for Iterative 2D and a recommended parameter by Siemens for True X are applied to the experiment. Results: We tested FWHM using capillary tube. As a result, TrueX was less than Iterative 2D. Also, the differences of FWHM get bigger in low dose. On the other hand, we tested contrasts ratio using NEMA IEC PET body phantom. As a result, TrueX was better aspect than Iterative 2D. However, there was no difference in dose. Conclusion: In this experiment, TrueX get higher results of contrast ratio and spatial resolution than Itertive 2D through experiment. Also, in the reconstruction result through TrueX, TrueX had better aspect of resolution than Iterative 2D in low dose. However, contrast ratio had no specific difference. In other words, TrueX reconstruction method in PET/CT had higher clinical value in use because TrueX can reduce exposure of patient and had a better quality of screen.

  • PDF

Making Aids of Magnetic Resonacnce Image Susing 3D Printing Technology (3D 프린트를 활용한 자기공명영상검사 보조기구 제작)

  • Choi, Woo jeon;Ye, Soo young;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.403-409
    • /
    • 2016
  • MRI scan is a useful method in the diagnosis of musculoskeletal excellent contrast of the organization. Depending on the patient's musculoskeletal examinations state the type of aids provided the aid is used there is also challenging as well as the costs do not vary. This study was produced by the use of 3D printing technology, an MRI aids. Aids in the production process, then through 3D modeling and then convert stl files using (3D MAX.2014, Fusion360) slicing programs (Cubicreater 2.1ver., Cura 15.4ver) converted to G-code printed on the FDM scheme (Cubicon Style, output was MICRO MAKE). Output is, but in the FDM to evaluate the SNR on the MRI images were compared to the test is the case before use, and then to produce a Water Phantom case of a PLA, ABS, a TPU thickness 3mm, using aids before, It was evaluated in a clinical image after qualitatively. Obtaining an image of SNR Warter Phantom appeared to have been evaluated as T1 NON $123.778{\pm}28.492$, PLA $123.522{\pm}28.373$, ABS $124.461{\pm}25.716$, TPU $124.843{\pm}27.272$. T2 NON $127.421{\pm}26.949$, was rated as PLA $124.501{\pm}27.768$, ABS $128.663{\pm}26.549$, TPU $130.171{\pm}25.998$. The results did not show statistically significant differences. The use of assistive devices before and after images Clinical evaluation method palliative $3.20{\pm}0.88$, $3.95{\pm}0.76$ after using the aids used to aid improved the quality of the image. Production of the auxiliary mechanism using a future 3D printing is expected are thought to be used clinically, it can be an aid making safe and comfortable than the inspection of the patient is an alternative to improve the problems of the aids used in the conventional do.

Lumbar Angiomatous Meningioma in a Dog (개에서 발생한 요추 혈관종성수막종 증례)

  • Sohn, Jung-Min;Kim, Bo-Eun;Jung, Sun-Young;Ji, Seo-Yeoun;Yoon, Dae-Young;Kweon, Oh-Kyeong;Kim, Dae-Yong;Choi, Min-Cheol;Yoon, Junghee
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.152-155
    • /
    • 2014
  • An 11-year-old castrated Schnauzer presented with paraplegia for the last two weeks, initially developed pelvic limb ataxia 6 months ago and left pelvic limb paresis 3 months ago. On neurological examination, paraplegia and postural reaction deficits were noted in the pelvic limbs with no deep pain sensation, and the dog showed exaggerated spinal reflexes and involuntary urination. Magnetic resonance (MR) images of thoracolumbar spinal cord were obtained with a 0.3 Tesla magnet. A mass with a broad base to the dorsal and left dural margins was identified at the level of L2, causing marked spinal cord compression. The mass showed isointensity to the spinal cord on T1-weighted (T1W) precontrast images, hyperintensity on T2-weighted images, marked homogeneous contrast enhancement with well-defined margins and the "dural tail" sign on T1W postcontrast images. An intradural-extramedullay tumor was considered, most likely, meningioma was highly suggestive. Left-sided hemilaminectomy and dorsal laminectomy were performed. An intradural mass partially adherent to dura mater was compressing the spinal cord, and the mass was completely removed with the attached dura mater. A histopathologic diagnosis of angiomatous subtype meningioma was made.

Schwannoma of the Extremities (사지에 발생한 신경초종)

  • Bahk, Won-Jong;Rhee, Seung-Koo;Kang, Yong-Koo;Lee, An-Hi
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.2
    • /
    • pp.148-154
    • /
    • 2003
  • Purpose: To correlate the significant MRI findings and histologic features of the Schwannoma of the extremities and to review the clinical characteristic and the result of the surgical enucleation. Materials and Methods: 67 patients with pathologically proven Schwannoma of the extremities, who were surgically treated at our institutes between January 1996 and June 2002, were selected for this study. The clinical records, EMG, MRI and histologic findings were reviewed. Age of the patients ranged from 8 to 75 years with average of 44.7 years. Mean follow-up period was 9.7 months with raging from 3 months to 46 months. Results: On MRI, Schwannoma shows a well-demarcated fusiform mass with a low to intermediate signal intensity on T1-weighted images and high signal intensity on T2-weighted images, which is connected to parent nerve. A target pattern with peripheral hyperintensive rim and central low intensity on T2-weighted images was seen in 6 cases (15%), and fasciculation pattern with inhomogenous intensity in the hyperintensity on T2-weighted images was observed in 24 cases (62%). Various degree of cystic degeneration was discovered in 25 cases (64%). Postoperative complications include tingling sense or radiating pain in 5 patients, paresthesia in 2 patients, nerve palsy in 2 patients, but all of the complications were recovered during followup period. There were no local recurrence or malignant change. Conclusion: MRI demonstrates characteristic findings of Schwannoma, and very useful tool for preoperative diagnosis and planning of surgery. Exact preoperative diagnosis and meticulous enucleation are enough option of treatment.

  • PDF