• Title/Summary/Keyword: 성능 평가 기준

Search Result 2,406, Processing Time 0.031 seconds

Seismic Performance Evaluation of Nonseismic Neighborhood Living Facilities Considering Deterioration (비내진 근린생활시설의 노후도를 고려한 내진성능평가)

  • Lee, Young Cheon;Jeoung, Chae Myeoung;Lee, Eun Jin;Kim, Myung Hoon;Choi, Ki Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • In this study, seismic performance was evaluated considering the deterioration level for the low-rise and moderate buildings with non-seismic details which are most common in Korea. Evaluation results showed that the deterioration condition is relatively good even after 24 years of construction but the seismic performance did not satisfy the protection index in the first and second evaluation. In case of the third evaluation, the goal performance was satisfied based on the interstory drift ratio but reinforcement is found to be necessary. Seismic performance was evaluated after the target buildings were reinforced in the walls, bracing, and damper. Results showed the interstory drift ratio drastically reduced regardless of reinforcement methods and satisfied the level of immediate occupancy. In case of wall reinforcement, however, base shear increased more than double which requires review on the existing foundation.

Performance Evaluation of the Cast-in-place Anchor Bolt in Non-cracked Concrete used in Power Plant Facilities (비균열 콘크리트에 매립된 발전설비 정착부 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jong, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.250-258
    • /
    • 2019
  • The seismic performance and stability of operating facilities installed in domestic power plants need to be verified because of the increased incidence of earthquakes resulting in power plant damage due to the overturning failure of electric operating facilities. In this study, a structural performance evaluation of the anchor bolts constructed to setup the operating facilities on concrete slabs was carried out through an on-site inspection of power plants, called Daechung-Dam. M10 J hook and M12 J hook anchor bolts were installed in the field unit. According to the ASTM E 488-96 specifications, anchor bolt pullout and shear tests were carried out and compared with the anchor-bolt design standards. The results from the tension and shear pullout tests showed that the M10 and M12 J hook anchor bolts had higher performance than the required design load. Thus, they were found to be safe enough. Nevertheless, more research in the field of analytical study will be needed in the near future.

BER Performance Evaluation on the Method of Balancing Information Potentials for Blind Equalization (블라인드 등화를 위한 정보 포텐셜 분배 방법에 대한 BER 성능 분석)

  • Kim, Namyong;Kwon, Kihyun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.1
    • /
    • pp.51-57
    • /
    • 2009
  • Blind equalization techniques have been widely used in wireless communication systems. In this paper, we investigate the information potentials in the criterion of minimizing Euclidian distance between two PDFs criterion for adaptive blind equalizers and evaluate BER performance of the method that has utilized an appropriate balance between the two information potentials, one from output samples and ramdomly generated desired samples at the receiver and another from the interactions among output samples. The balanced information potential method has shown in the BER performance results that it can produce significantly enhanced BER performance in blind equalization applications.

  • PDF

Lever Arm Compensation of Reference Trajectory for Flight Performance Evaluation of DGPS/INS installed on Aircraft (항공기에 탑재된 DGPS/INS 복합항법 장치의 비행 시험 성능 평가를 위한 기준궤적의 Lever Arm 보정)

  • Park, Ji-Hee;Lee, Seong-Woo;Park, Deok-Bae;Shin, Dong-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1086-1092
    • /
    • 2012
  • It has been studied for DGPS/INS(Differential Global Positioning System/Inertial Navigation System) to offer the more precise and reliable navigation data with the aviation industry development. The flight performance evaluation of navigation system is very significant because the reliability of navigation data directly affect the safety of aircraft. Especially, the high-level navigation system, as DGPS/INS, need more precise flight performance evaluation method. The performance analysis is performed by comparing between the DGPS/INS navigation data and reference trajectory which is more precise than DGPS/INS. The GPS receiver, which is capable of post-processed CDGPS(Carrier-phase DGPS) method, can be used as reference system. Generally, the DGPS/INS is estimated the CG(Center of Gravity) point of aircraft while the reference system is output the position of GPS antenna which is mounted on the outside of aircraft. For this reason, estimated error between DGPS/INS and reference system will include the error due to lever arm. In order to more precise performance evaluation, it is needed to compensate the lever arm. This paper presents procedure and result of flight test which includes lever arm compensation in order to verify reliability and performance of DGPS/INS more precisely.

A Study on the Establishment of Housing Performance Criteria for Modular Building (모듈러 건축물의 거주환경 성능기준 설정에 관한 연구;음환경 성능을 중심으로)

  • Ko, Kwang-Il;Kim, Yong-In;Lee, Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.628-631
    • /
    • 2006
  • Modular Construction is a method, which factory-produced units are transferred to on-site and assembled to form complete buildings. It is expected that its demand will increase gradually. Because it has some advantages such as duration reduction, movement, reuse and environmental friendliness etc. For the Modular Construction to be introduced and applied, we needs the objective and reasonable performance criteria. This study presents the acoustic performance criteria of the modular building. For this one, this paper reviews legal standard related to performance, analyzes the performance evaluation and survey on pilot projects. The presented performance criteria can be specifically asked the demand by owner in a design guideline. In addition, it makes designer and general contractor accomplish target performance. Eventually, it can improve the performance of Modular Building.

  • PDF

Experiment and Evaluation of Medical Smartphone Applications (의료용 스마트폰 실험과 평가)

  • Park, Set-Byeol;Kim, Il-Kon;Yi, Byoung-Kee
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2011.06c
    • /
    • pp.214-216
    • /
    • 2011
  • 최근 의료영역에서 개인건강관리 기능을 갖춘 어플리케이션에서부터 병원에서 진료를 목적으로 사용할 수 있는 어플리케이션까지 다양한 의료용 스마트폰 어플리케이션이 출시되었다. 이에 의료용 스마트폰 어플리케이션의 성능평가를 위하여 의료용 스마트폰 어플리케이션 성능평가 실험을 설계하고, 유헬스와 관련된 안전성, 유효성 평가에 관한 국내외 규격을 조사하여 의료용 스마트폰 어플리케이션 안전성 평가시험항목, 시험기준을 활용하여 의료영역에서 사용되는 모바일 어플리케이션에 대한 안전성 평가기준을 제시한다.

Developments of performance-based evaluation criteria of utility tunnel (성능중심의 공동구 평가 기준 개발)

  • Byun, Yo-Seph;Seong, Joo-Hyun;Cho, Gey-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.715-724
    • /
    • 2022
  • With the enforcement of the infrastructure management act, the importance of utility tunnels that jointly accommodate life-lines such as electricity, communication, water supply, and heating facilities has increased. The currently applied utility tunnel maintenance system is managed in an accident-preventive safety-based evaluation method. However, this evaluation method has limitations in effective maintenance. In this study, performance evaluation items were derived through the Delphi method to suggest a criterion for quantitatively evaluating the performance of utility tunnels, and the weights for each item were calculated through the Analytic Hierarchy Process (AHP) method. In the future, it is judged that a more reasonable performance evaluation standard of utility tunnel can be prepared if modifications and supplements are made through field application.

Development of performance testing technique and standard for low voltage air circuit breaker (저압 기증차단기의 규격 및 성능평가기술 개발)

  • Ahn, Sang-Pil;Ryu, Jae-Nam;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.717-718
    • /
    • 2006
  • 최근 저압 기중차단기(ACB, Air Circuit Breaker)는 고압중전기 공인시험제도 및 저압전기기기 안전인증제도와 같은 강제인중 대상에서 제외되어 해당 성능에 대한 안전 사각지대에 놓여있다는 지적을 받아왔다. 본 논문에서는 현재의 ACB관련 규격 및 성능평가기술을 분석하고, 국제규격과의 비교 분석을 통하여 국제규격에 준하는 성능평가기술 및 규격을 제시하는 방안을 연구하였다. 특히 내년에 제정이 논의되고 있는 ACB관련 KS 규격의 제정 방향 및 KS 심사기준에 대한 진행방향 설정과 연구되어야할 성능평가기술을 제품성능 특성별로 제시하였다. 향후 본 논문의 성능평가기술 및 제안 방향이 KS규격 제정 및 활용에 중요한 근간을 제공할 것으로 기대한다.

  • PDF

Evaluation Method of Talk Level on the Speaker Phone (스피커폰 통화 음량의 평가 방법)

  • Yoo, Heun-Seung;Kim, Tae-Woo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.759-761
    • /
    • 2009
  • 본 논문에서는 스피커폰의 통화 음량 평가 방법을 제안하였다. 이 방법은 ITUT P.340과 3GPP TS26.132의 규격을 참고하여 평가 기준을 만들었다. 제안한 평가 기준은 정량적이므로 스피커폰의 품질 수준을 일괄적으로 관리 할 수 있게 되었다. 실험에서 본 논문의 평가 방법이 기존의 감성적 방법보다 향상된 통화 성능을 보였다.

  • PDF

Comparison of The Importance of Evaluation Items for Landscape Performance and Sustainability Using Analytic Network Process (ANP) (ANP기법을 이용한 조경성능 및 친환경 평가항목 중요도 비교)

  • Ryu, Myeung-Ji;Lee, Hyung-Sook
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.6
    • /
    • pp.45-52
    • /
    • 2019
  • As international criteria and standards are required in the fields of design and construction, landscape performance must also be considered not only for the value of the landscape but also for providing quality assurance and sustainability. Given the lack of research on landscape performance, the present research was purposed to analyze the importance of potential assessment categories and items using an analytical network process. A list of assessment items, which is composed of 20 items and 6 categories, was derived through a literature review and a preliminary survey of 11 landscape professionals. An ANP model was established and a survey was conducted among 30 landscape practitioners to determine the weight of priorities considering the criteria. The results of ANP showed that the categories of site selection, preservation and health, and convenience had high priorities while materials had the lowest importance score. For the assessment items, a monitoring plan was the highest importance, followed by cultural/ historic preservation, management cost reduction, and natural ground areas. Despite the difficulties in quantifying landscape achievements, most respondents agreed that there needs to be an evaluation system for landscape performance in order to assure the quality and sustainability of landscape development. More research and discussion are needed to develop an assessment system for landscape performance that is applicable to Korean context.